Chulcova, G. M., Ptitsina, N. G., Gershenzon, E. M., Gershenzon, M. E., & Sergeev, A. V. (1996). Effect of the interference between electron-phonon and electron-impurity (boundary) scattering on resistivity Nb, Al, Be films. In Czech J. Phys. (Vol. 46, pp. 2489–2490).
Abstract: The temperature dependence of the resistivity of thin Nb, Al, Be films has been studied over a wide temperature range 4-300 K. We have found that the temperature-dependent correction to the residual resistivity is well described by the sum of the Bloch-Grüneisen term and the term originating from the interference between electron-phonon and electron-impurity scattering. Study of the transport interference phenomena allows to determine electron-phonon coupling in disordered metals. The interference term is proportional to T2 and also to the residual resistivity and dominates over the Bloch-Grüneisen term at low temperatures (T<40 K).
|
|
|
Il'in, K. S., Karasik, B. S., Ptitsina, N. G., Sergeev, A. V., Gol'tsman, G. N., Gershenzon, E. M., et al. (1996). Electron-phonon-impurity interference in thin NbC films: electron inelastic scattering time and corrections to resistivity. In Czech. J. Phys. (Vol. 46, pp. 857–858).
Abstract: Complex study of transport properties of impure NbC films with the electron mean free pathl=0.6–13 nm show the crucial role of the electron-phonon-impurity interference (EPII). In the temperature range 20–70 K we found the interference correction to resistivity proportional to T2 and to the residual resistivity of the film. Using the comprehensive theory of EPII, we determine the electron coupling with transverse phonons and calculate the electron inelastic scattering time. Direct measurements of the inelastic electron scattering time using a response to a high-frequency amplitude modulated cw radiation agree well with the theory.
|
|
|
Tiulina, V., Iomdina, E., Goltsman, G., Seliverstov, S., Sianosyan, A., Teplyakova, K., et al. (2019). UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo (Vol. 9).
Abstract: Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for noninvasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 161500255.
|
|
|
Гольцман, Г. Н., Корнеев, А. А., Антипов, А. В., Минаева, О. В., Дивочий, А. В., Антипов, С. В., et al. (2014). Способ фильтрации фонового излучения инфракрасного диапазона.
Abstract: Изобретение относится к способам уменьшения интенсивности фонового излучения инфракрасного диапазона. Способ фильтрации фонового излучения инфракрасного диапазона, падающего на сверхпроводниковый однофотонный детектор, включает передачу излучения инфракрасного диапазона с длиной волны 0,4-1,8 микрометров на сверхпроводниковый однофотонный детектор при помощи одномодового волокна, частично находящегося при температуре 4,0-4,4 К. При этом длина охлаждаемого участка одномодового волокна составляет 0,2-3,5 м. Технический результат заключается в повышении надежности работы фотонных детекторов. 2 з.п. ф-лы.
|
|
|
Антипов, А. В., Дивочий, А. В., Вахтомин, Ю. Б., Финкель, М. И., & Смирнов, К. В. (2014). Способ прецизионного позиционирования чувствительного элемента фотонного детектора.
Abstract: Изобретение относится к способам, позволяющим производить совмещение фотонных детекторов относительно оптического излучения. Способ прецизионного позиционирования чувствительного элемента фотонного детектора относительно амплитудно-модулированного оптического излучения включает смещение чувствительного элемента фотонного детектора постоянным током с последующей регистрацией электрического сигнала, возникающего на контактах детектора на частоте модуляции излучения. Полученный при этом сигнал используют как параметр, определяющий качество позиционирования. Обеспечивается повышение технико-эксплуатационных характеристик детектора.
|
|