Gershenzon, E. M., Gol'tsman, G. N., & Elant'ev, A. I. (1977). Energy spectrum of the donors in GaAs and Ge and its reaction to a magnetic field. Sov. Phys. JETP, 45(3), 555–565.
Abstract: The spectrum of the submillimeter photoconductivity of n-GaAs and n-Ge in a magnetic field up to 60 kOe at helium temperatures was investigated. A large number of lines due to transitions between excited states of the donors have been investigated, and the measurement results were used to determine a number of levels of the energy spectrum in a wide range of magnetic fields. For GaAs, these data are compared with calculations of the energy spectrum of the hydrogen atom in magnetic fields up to -2X lo9 Oe. For the donors in Ge, the energy spectrum is investigated at different orientations of the magnetic field relative to the crystallographic axes (H 11 [loo], [I 1 I], [110]), and these results are also compared with the corresponding calculations.
|
|
|
Gershenzon, E. M., Orlova, S. L., Orlov, L. A., Ptitsina, N. G., & Rabinovich, R. I. (1976). Intervalley cyclotron-impurity resonance of electrons in n-Ge. JETP Lett., 24(3), 125–128.
|
|
|
Gershenzon, E. M., Gol'tsman, G., & Ptitsina, N. G. (1973). Energy spectrum of free excitons in germanium. JETP Lett., 18(3), 93.
|
|
|
Kawamura, J., Blundell, R., Tong, C. - Y. E., Papa, D. C., Hunter, T. R., Paine, S. N., et al. (2000). Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation. IEEE Trans. Microw. Theory Techn., 48(4), 683–689.
Abstract: In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-μm atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is TRX=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is PLO≈1 μW. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
|
|
|
Antipov, S. V., Svechnikov, S. I., Smirnov, K. V., Vakhtomin, Y. B., Finkel, M. I., Goltsman, G. N., et al. (2001). Noise temperature of quasioptical NbN hot electron bolometer mixers at 900 GHz. Physics of Vibrations, 9(4), 242–245.
|
|