Records |
Links |
|
Author |
Arams, F.; Allen, C.; Peyton, B.; Sard, E. |
|
|
Title |
Millimeter mixing and detection in bulk InSb |
Type |
Conference Article |
|
Year |
1966 |
Publication |
Proc. IEEE |
Abbreviated Journal |
|
|
|
Volume |
54 |
Issue |
4 |
Pages |
612-622 |
|
|
Keywords |
InSb, mixer, detector |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
219 |
|
Permanent link to this record |
|
|
|
|
Author |
Korneeva, Yuliya; Florya, Irina; Vdovichev, Sergey; Moshkova, Mariya; Simonov, Nikita; Kaurova, Natalia; Korneev, Alexander; Goltsman, Gregory |
|
|
Title |
Comparison of hot-spot formation in NbN and MoN thin superconducting films after photon absorption |
Type |
Conference Article |
|
Year |
2017 |
Publication |
IEEE Transactions on Applied Superconductivity |
Abbreviated Journal |
IEEE Transactions on Applied Superconductiv |
|
|
Volume |
27 |
Issue |
4 |
Pages |
5 |
|
|
Keywords |
Thin film devices, Superconducitng photoncounting devices, Nanowire single-photon detectors |
|
|
Abstract |
In superconducting single-photon detectors SSPD
the efficiency of local suppression of superconductivity and hotspot
formation is controlled by diffusivity and electron-phonon
interaction time. Here we selected a material, 3.6-nm-thick MoNx
film, which features diffusivity close to those of NbN traditionally
used for SSPD fabrication, but with electron-phonon interaction
time an order of magnitude larger. In MoNx detectors we study
the dependence of detection efficiency on bias current, photon
energy, and strip width and compare it with NbN SSPD. We
observe non-linear current-energy dependence in MoNx SSPD
and more pronounced plateaus in dependences of detection
efficiency on bias current which we attribute to longer electronphonon
interaction time. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ kovalyuk @ |
Serial |
1114 |
|
Permanent link to this record |
|
|
|
|
Author |
Gol'tsman, G. N.; Goghidze, I. G.; Kouminov, P. B.; Karasik, B. S.; Semenov, A. D.; Gershenzon, E. M. |
|
|
Title |
Influence of grain boundary weak links on the nonequilibrium response of YBaCuO thin films to short laser pulses |
Type |
Journal Article |
|
Year |
1994 |
Publication |
J. Supercond. |
Abbreviated Journal |
J. Supercond. |
|
|
Volume |
7 |
Issue |
4 |
Pages |
751-755 |
|
|
Keywords |
YBCO HTS detector, nonequilibrium response |
|
|
Abstract |
The transient voltage response in both epitaxial and granular YBaCuO thin films to 80 ps pulses of YAG∶Nd laser radiation of wavelength 0.63 and 1.54 μm was studied. In the normal and resistive states both types of films demonstrate two components: a nonequilibrium picosecond component and a bolometric nanosecond one. The normalized amplitudes are almost the same for all films. In the superconducting state we observed a kinetic inductive response and two-component shape after integration. The normalized amplitude of the response in granular films is up to five orders of magnitude larger than in epitaxial films. We interpret the nonequilibrium response in terms of a suppression of the order parameter by the excess of quasiparticles followed by the change of resistance in the normal and resistive states or kinetic inductance in the superconducting state. The sharp rise of inductive response in granular films is explained both by a diminishing of the cross section for current percolation through the disordered network of Josephson weak links and by a decrease of condensate density in neighboring regions. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0896-1107 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1636 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Semenov, A. D.; Sergeev, A. V. |
|
|
Title |
Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation |
Type |
Journal Article |
|
Year |
1990 |
Publication |
Solid State Communications |
Abbreviated Journal |
Solid State Communications |
|
|
Volume |
76 |
Issue |
4 |
Pages |
493-497 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
The ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter to near infrared. With the rise of radiation frequency the Josephson detection at the grain boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. Electron-phonon relaxation time τeph is determined by direct measurements and analyses quasistationary electron heating. Temperature dependence of τeph at T ≤ 40 K was found to be τeph ∼ T−1. The results show that detectors with the response time of few picoseconds at nitrogen temperature are attainable. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0038-1098 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1685 |
|
Permanent link to this record |
|
|
|
|
Author |
Ryzhii, V.; Otsuji, T.; Ryzhii, M.; Leiman, V. G.; Fedorov, G.; Goltzman, G. N.; Gayduchenko, I. A.; Titova, N.; Coquillat, D.; But, D.; Knap, W.; Mitin, V.; Shur, M. S. |
|
|
Title |
Two-dimensional plasmons in lateral carbon nanotube network structures and their effect on the terahertz radiation detection |
Type |
Journal Article |
|
Year |
2016 |
Publication |
J. Appl. Phys. |
Abbreviated Journal |
J. Appl. Phys. |
|
|
Volume |
120 |
Issue |
4 |
Pages |
044501 (1 to 13) |
|
|
Keywords |
carbon nanotubes, CNT detectors, plasmons |
|
|
Abstract |
We consider the carrier transport and plasmonic phenomena in the lateral carbon nanotube (CNT) networks forming the device channel with asymmetric electrodes. One electrode is the Ohmic contact to the CNT network and the other contact is the Schottky contact. These structures can serve as detectors of the terahertz (THz) radiation. We develop the device model for collective response of the lateral CNT networks which comprise a mixture of randomly oriented semiconductor CNTs (s-CNTs) and quasi-metal CNTs (m-CNTs). The proposed model includes the concept of the collective two-dimensional (2D) plasmons in relatively dense networks of randomly oriented CNTs (CNT “felt”) and predicts the detector responsivity spectral characteristics exhibiting sharp resonant peaks at the signal frequencies corresponding to the 2D plasmonic resonances. The detection mechanism is the rectification of the ac current due the nonlinearity of the Schottky contact current-voltage characteristics under the conditions of a strong enhancement of the potential drop at this contact associated with the plasmon excitation. The detector responsivity depends on the fractions of the s- and m-CNTs. The burning of the near-contact regions of the m-CNTs or destruction of these CNTs leads to a marked increase in the responsivity in agreement with our experimental data. The resonant THz detectors with sufficiently dense lateral CNT networks can compete and surpass other THz detectors using plasmonic effects at room temperatures. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0021-8979 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1777 |
|
Permanent link to this record |
|
|
|
|
Author |
Seliverstov, S.; Maslennikov, S.; Ryabchun, S.; Finkel, M.; Klapwijk, T. M.; Kaurova, N.; Vachtomin, Yu.; Smirnov, K.; Voronov, B.; Goltsman, G. |
|
|
Title |
Fast and sensitive terahertz direct detector based on superconducting antenna-coupled hot electron bolometer |
Type |
Journal Article |
|
Year |
2015 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
|
|
Volume |
25 |
Issue |
3 |
Pages |
2300304 |
|
|
Keywords |
HEB detector responsivity, HEB model, numerical calculations, numerical model |
|
|
Abstract |
We characterize superconducting antenna-coupled hot-electron bolometers for direct detection of terahertz radiation operating at a temperature of 9.0 K. The estimated value of responsivity obtained from lumped-element theory is strongly different from the measured one. A numerical calculation of the detector responsivity is developed, using the Euler method, applied to the system of heat balance equations written in recurrent form. This distributed element model takes into account the effect of nonuniform heating of the detector along its length and provides results that are in better agreement with the experiment. At a signal frequency of 2.5 THz, the measured value of the optical detector noise equivalent power is 2.0 × 10-13 W · Hz-0.5. The value of the bolometer time constant is 35 ps. The corresponding energy resolution is about 3 aJ. This detector has a sensitivity similar to that of the state-of-the-art sub-millimeter detectors operating at accessible cryogenic temperatures, but with a response time several orders of magnitude shorter. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
953 |
|
Permanent link to this record |
|
|
|
|
Author |
Zhang, W.; Miao, W.; Li, S. L.; Zhou, K. M.; Shi, S. C.; Gao, J. R.; Goltsman, G. N. |
|
|
Title |
Measurement of the spectral response of spiral-antenna coupled superconducting hot electron bolometers |
Type |
Journal Article |
|
Year |
2013 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
|
|
Volume |
23 |
Issue |
3 |
Pages |
2300804-2300804 |
|
|
Keywords |
NbN HEB detector |
|
|
Abstract |
Measured spectral response of spiral-antenna coupled superconducting hot electron bolometers (HEBs) often drops dramatically at frequencies that are still within the frequency range of interest (e.g., ~ 5 THz). This is inconsistent with the implied low receiver noise temperatures from the same measurements. To understand this discrepancy, we exhaustively test and calibrate the thermal sources used in Fourier transform spectrometer measurements. We first investigate the absolute emission spectrum of high-pressure Hg arc lamp, then measure the spectral response of two spiral-antenna coupled NbN HEBs with a Martin-Puplett interferometer as spectrometer and 77 K blackbody as broadband signal source. The measured absolute emission spectrum of Hg arc lamp is proportional to frequency, corresponding to an equivalent blackbody temperature of 4000 K at 1 THz, 1500 K at 3 THz, and 800 K at 5 THz, respectively. Measured spectral response of spiral-antenna coupled NbN HEBs, corrected for air absorption, is nearly flat in the frequency range of 0.5-4 THz, consistent with simulated coupling efficiency between HEB and spiral-antenna. These results explain the discrepancy, and prove that spiral-antenna coupled superconducting NbN HEBs work well in a wide frequency range. In addition, this calibration method and these results are broadly applicable to other quasi-optical THz receivers. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1051-8223 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1371 |
|
Permanent link to this record |
|
|
|
|
Author |
Danerud, M.; Winkler, D.; Lindgren, M.; Zorin, M.; Trifonov, V.; Karasik, B. S.; Gol’tsman, G. N.; Gershenzon, E. M. |
|
|
Title |
Nonequilibrium and bolometric photoresponse in patterned YBa2Cu3O7−δ thin films |
Type |
Journal Article |
|
Year |
1994 |
Publication |
J. Appl. Phys. |
Abbreviated Journal |
J. Appl. Phys. |
|
|
Volume |
76 |
Issue |
3 |
Pages |
1902-1909 |
|
|
Keywords |
YBCO HTS HEB detector, nonequilibrium response |
|
|
Abstract |
Epitaxial laser deposited YBa2Cu3O7−δ films of ∼50 nm thickness were patterned into detectors consisting of ten parallel 1 μm wide strips in order to study nonequilibrium and bolometric effects. Typically, the patterned samples had critical temperatures around 86 K, transition widths around 2 K and critical current densities above 1×106A/cm2 at 77 K. Pulsed laser measurements at 0.8 μm wavelength (17 ps full width at half maximum) showed a ∼30 ps response, attributed to electron heating, followed by a slower bolometric decay. Amplitude modulation in the band fmod=100 kHz–10 GHz of a laser with wavelength λ=0.8 μm showed two different thermal relaxations in the photoresponse. Phonon escape from the film (∼3 ns) is the limiting process, followed by heat diffusion in the substrate. Similar relaxations were also seen for λ=10.6 μm. The photoresponse measurements were made with the film in the resistive state and extended into the normal state. These states were created by supercritical bias currents. Measurements between 75 and 95 K (i.e., from below to above Tc) showed that the photoresponse was proportional to dR/dT for fmod=1 MHz and 4 GHz. The fast response is limited by the electron‐phonon scattering time, estimated to 1.8 ps from experimental data. The responsivity both at 0.8 and 10.6 μm wavelength was ∼1.2 V/W at fmod=1 GHz and the noise equivalent power was calculated to 1.5×10−9 WHz−1/2 for the fast response. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0021-8979 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1637 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gogidze, I. G.; Goltsman, G. N.; Semenov, A. D.; Sergeev, A. V. |
|
|
Title |
Picosecond response on optical-range emission in thin YBaCuO films |
Type |
Journal Article |
|
Year |
1991 |
Publication |
Pisma v Zhurnal Tekhnicheskoi Fiziki |
Abbreviated Journal |
Pisma v Zhurnal Tekhnicheskoi Fiziki |
|
|
Volume |
17 |
Issue |
22 |
Pages |
6-10 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
Целью настоящей работы является целенаправленный поиск пико-секундного отклика на оптическое излучение выяснение оптимальных условий его наблюдения, а также сравнение характеристик неравновесных эффектов в оптическом и субмиллиметровом диапазонах. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
Russian |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1684 |
|
Permanent link to this record |
|
|
|
|
Author |
Zhang, Zijing; Zhang, Jianlong; Wu, Long; Zhang, Yong; Zhao, Yuan; Su, Jianzhong |
|
|
Title |
Photon-counting chirped amplitude modulation lidar using a smart premixing method |
Type |
Journal Article |
|
Year |
2013 |
Publication |
Opt. Lett. |
Abbreviated Journal |
Opt. Lett. |
|
|
Volume |
38 |
Issue |
21 |
Pages |
4389-4392 |
|
|
Keywords |
photon-counting detector, lidar, Geiger mode APD, Geiger mode lidar |
|
|
Abstract |
We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1006 |
|
Permanent link to this record |