|
Gershenzon, E. M., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1990). Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation. Solid State Communications, 76(4), 493–497.
Abstract: The ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter to near infrared. With the rise of radiation frequency the Josephson detection at the grain boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. Electron-phonon relaxation time τeph is determined by direct measurements and analyses quasistationary electron heating. Temperature dependence of τeph at T ≤ 40 K was found to be τeph ∼ T−1. The results show that detectors with the response time of few picoseconds at nitrogen temperature are attainable.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Mirskii, G. I. (1987). Submillimeter backward-wave-tube spectrometer-relaxometer. Pribory i Tekhnika Eksperimenta, 30(4), 131–137.
Abstract: A backward-wave-tube (BWT) spectrometer-relaxometer is described that is designed for study of the relaxation characteristics of photoconductors in the wavelength range of 2-0.25 mm – in particular, to measure the relaxation times of the submillimeter photoconductivity of germanium in the range of 10[sup:-4]-10[sup:-9] sec and to determine from these data the concentration of compensating impurities of from 10[sup:10] to 10[sup:14] cm[sup:-3]. The instrument uses the beats of the oscillations of two BWTs and records the amplitude-frequency response of the specimen with variation of the beat frequency from 10[sup:4] to 10[sup:8] Hz with accumulation of the desired signal for less than or equal to1 sec by means of a quadrature synchronous detector. The beat frequency is stabilized and the quadrature voltages of the synchronous detector are formed by means of phase-locked loops.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., Ptitsina, N. G., & Riger, E. R. (1986). Effect of electron-electron collisions on the trapping of free carriers by shallow impurity centers in germanium. Sov. Phys. JETP, 64(4), 889–897.
Abstract: Cascade Auger recombination of free carriers on shallow impurities in Ge is investigated under quasi-equilibrium conditions (T= 2-12 K) and in impurity breakdown. The Auger capture cross sections are found to be a,= 5. 10-l9 T-'n cm2 for donors and uip= 7- T-5p cm2 for acceptors. It is shown that in an isotropic semiconductor (p-Ge) ui is well described by the cascade-capture theory that takes into account only electron-electron collisions. In an anisotropic semiconductor ui is considerably larger (n-Ge, strongly uniaxially compressedp-Ge). Under impurity breakdown conditions the electron-electron collisions determine the lifetimes of the free carriers only in samples with appreciable density of the compensating impurity (Nk loi3 cmP3).
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Ptitsina, N. G. (1972). Observation of the free-exciton spectrum at submillimeter wavelengths. JETP Lett., 16(4), 161–162.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., Multanovskii, V. V., & Ptitsyna, N. G. (1979). Capture of photoexcited carriers by shallow impurity centers in germanium. Sov. Phys. JETP, 50(4), 728–734.
Abstract: Measurements were made of the lifetimes rf of free carriers and the relaxation time 7, of the submillimeter impurity photoconductivity when carriers are captured by attracting shallow donors and acceptom in Ge. It is nod that in samples with capture-center concentration N,Z 10"cm-' the relaxation time 7, greatly exceeds rf in the temperature range 4.2-12 K. The measured values of 7,- are compared with the calculation of cascade recombination by the classical model. To evaluate the data on T,, the distinguishing features of this model are considered for the nonstationary case. The substantial difference betweea the values of rf and T, is attributed to re-emission of the carriers from the excited states of the shallow impurities.
|
|