Gayduchenko, I., Kardakova, A., Fedorov, G., Voronov, B., Finkel, M., Jiménez, D., et al. (2015). Response of asymmetric carbon nanotube network devices to sub-terahertz and terahertz radiation. J. Appl. Phys., 118(19), 194303.
Abstract: Demand for efficient terahertz radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. It was maintained that photothermoelectric effect under certain conditions results in strong response of such devices to terahertz radiation even at room temperature. In this work, we investigate different mechanisms underlying the response of asymmetric carbon nanotube (CNT) based devices to sub-terahertz and terahertz radiation. Our structures are formed with CNT networks instead of individual CNTs so that effects probed are more generic and not caused by peculiarities of an individual nanoscale object. We conclude that the DC voltage response observed in our structures is not only thermal in origin. So called diode-type response caused by asymmetry of the device IV characteristic turns out to be dominant at room temperature. Quantitative analysis provides further routes for the optimization of the device configuration, which may result in appearance of novel terahertz radiation detectors.
|
Fedorov, G., Kardakova, A., Gayduchenko, I., Charayev, I., Voronov, B. M., Finkel, M., et al. (2013). Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-terahertz radiation. Appl. Phys. Lett., 103(18), 181121 (1 to 5).
Abstract: We report on the voltage response of carbon nanotube devices to sub-terahertz (THz) radiation. The devices contain carbon nanotubes (CNTs), which are over their length partially suspended and partially Van der Waals bonded to a SiO2 substrate, causing a difference in thermal contact. We observe a DC voltage upon exposure to 140 GHz radiation. Based on the observed gate voltage and power dependence, at different temperatures, we argue that the observed signal is both thermal and photovoltaic. The room temperature responsivity in the microwave to THz range exceeds that of CNT based devices reported before. Authors thank Professor P. Barbara for providing the catalyst for CNT growth and Dr. N. Chumakov and V. Rylkov for stimulating discussions. The work was supported by the RFBR (Grant No. 12-02-01291-a) and by the Ministry of Education and Science of the Russian Federation (Contract No. 14.B25.31.0007). G.F. acknowledges support of the RFBR grant 12-02-01005-a.
|
Shcherbatenko, M., Tretyakov, I., Lobanov, Y., Maslennikov, S. N., Kaurova, N., Finkel, M., et al. (2016). Nonequilibrium interpretation of DC properties of NbN superconducting hot electron bolometers. Appl. Phys. Lett., 109(13), 132602.
Abstract: We present a physically consistent interpretation of the dc electrical properties of niobiumnitride (NbN)-based superconducting hot-electron bolometer mixers, using concepts of nonequilibrium superconductivity. Through this, we clarify what physical information can be extracted from the resistive transition and the dc current-voltage characteristics, measured at suitably chosen temperatures, and relevant for device characterization and optimization. We point out that the intrinsic spatial variation of the electronic properties of disordered superconductors, such as NbN, leads to a variation from device to device.
|
Tret’yakov, I. V., Ryabchun, S. A., Kaurova, N. S., Larionov, P. A., Lobastova, A. A., Voronov, B. M., et al. (2010). Optimum absorbed heterodyne power for superconducting NbN hot-electron bolometer mixer. Tech. Phys. Lett., 36(12), 1103–1105.
Abstract: Absorbed heterodyne power has been measured in a low-noise broadband hot-electron bolometer (HEB) mixer for the terahertz range, operating on the effect of electron heating in the resistive state of an ultrathin superconducting NbN film. It is established that the optimum absorbed heterodyne power for the HEB mixer operating at 2.5 THz is about 100 nW.
|
Finkel, M. I., Maslennikov, S. N., & Gol'tsman, G. N. (2007). The concept of the receiving complex for the “Millimetron” space radio telescope. Radiophys. Quant. Electron., 50(10-11), 837–846.
Abstract: We consider the current status of research in the development of a submillimeter and far-infrared receiving instrument and propose promising solutions for the receivers of the spaceborne telescope “Millimetron,” which allow one to realize comprehensively the opportunities given by this international project administrated by the Astrospace Center of the P. N. Lebedev Physical Institute of the Russian Academy of Sciences.
|