Records |
Author |
Peter H. Siegel |
Title |
Terahertz technology |
Type |
Journal Article |
Year |
2002 |
Publication |
IEEE Trans. Microw. Theory Techn. |
Abbreviated Journal |
|
Volume |
50 |
Issue |
3 |
Pages |
910-928 |
Keywords |
THz applications |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
494 |
Permanent link to this record |
|
|
|
Author |
Semenov, A.; Engel, A.; Il'in, K.; Gol'tsman, G.; Siegel, M.; Hübers, H.-W. |
Title |
Ultimate performance of a superconducting quantum detector |
Type |
Journal Article |
Year |
2003 |
Publication |
Eur. Phys. J. Appl. Phys. |
Abbreviated Journal |
Eur. Phys. J. Appl. Phys. |
Volume |
21 |
Issue |
3 |
Pages |
171-178 |
Keywords |
NbN SSPD, SNSPD |
Abstract |
We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1286-0042 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
534 |
Permanent link to this record |
|
|
|
Author |
Cherednichenko, Sergey; Drakinskiy, Vladimir; Berg, Therese; Kollberg, Erik L.; Angelov, Iltcho |
Title |
The direct detection effect in the hot-electron bolometer mixer sensitivity calibration |
Type |
Journal Article |
Year |
2007 |
Publication |
IEEE Trans. Microw. Theory Techn. |
Abbreviated Journal |
|
Volume |
55 |
Issue |
3 |
Pages |
504-510 |
Keywords |
HEB, mixer, direct detection effect |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0018-9480 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
555 |
Permanent link to this record |
|
|
|
Author |
Burke, P. J.; Schoelkopf, R. J.; Prober, D. E.; Skalare, A.; Karasik, B. S.; Gaidis, M. C.; McGrath, W. R.; Bumble, B.; LeDuc, H. G. |
Title |
Mixing and noise in diffusion and phonon cooled superconducting hot-electron bolometers |
Type |
Journal Article |
Year |
1999 |
Publication |
J. Appl. Phys. |
Abbreviated Journal |
|
Volume |
85 |
Issue |
3 |
Pages |
1644-1653 |
Keywords |
HEB, mixer |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0021-8979 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
556 |
Permanent link to this record |
|
|
|
Author |
Fu, K.; Zannoni, R.; Chan, C.; Adams, S. H.; Nicholson, J.; Polizzi, E.; Yngvesson, K. S. |
Title |
Terahertz detection in single wall carbon nanotubes |
Type |
Journal Article |
Year |
2008 |
Publication |
Applied Physics Letters |
Abbreviated Journal |
Appl. Phys. Lett. |
Volume |
92 |
Issue |
3 |
Pages |
033105 |
Keywords |
HEB, single wall, carbon nanotube, CNT, SWNT, SWCNT, terahertz detection, THz |
Abstract |
It is reported that terahertz radiation from 0.69 to 2.54 THz has been sensitively detected in a device consisting of bundles of carbon nanotubes containing single wall metallic carbon nanotubes, quasioptically coupled through a lithographically fabricated antenna, and a silicon lens. The measured data are consistent with a bolometric detection process in the metallic tubes and the devices show promise for operation well above 4.2 K. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-6951 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
NEP is not shown |
Approved |
no |
Call Number |
|
Serial |
566 |
Permanent link to this record |