Snyder Hale, D. D. (2003). A thermal infrared heterodyne receiver with applications to astronomy. Berkeley, CA 94720.
|
|
|
Stéphane Claude. (2003). Sideband-separating SIS mixer for ALMA band 7, 275–370 GHz. In Proc. 14th Int. Symp. Space Terahertz Technol. (41). Tucson, USA.
|
|
|
Grimes, P., Kittara, P., Yassin, G., Withington, S., & Jacobs, K. (2003). Investigation of the performance of a 700 GHz nline mixer. In Proc. 14th Int. Symp. Space Terahertz Technol. (247). Tucson, USA.
|
|
|
Amato, M. J., Benford, D. J., Moseley, H. S., & Juan Roman. (2003). An engineering concept and enabling technologies for a large single aperture far-infrared observatory (SAFIR). In Proc. SPIE (Vol. 4850, pp. 1120–1131).
|
|
|
Albert Betz, Rita Boreiko, Yongdong Zhou, Jun Jhao, Yusuf Selamet, Yong Chang, et al. (2003). HgCdTe photoconductive mixers for 3-15 terahertz. In Proc. 14th Int. Symp. Space Terahertz Technol. (pp. 102–111). Tucson, USA.
|
|
|
Benford, D. J., Gaidis, M. C., & Kooi, J. W. (2003). Optical properties of Zitex in the infrared to submillimeter. Appl. Opt., 42(25), 5118.
|
|
|
Смирнов, К. В. (2003). AlGaAs/GaAs смеситель на эффекте разогрева двумерных электронов для тепловизора субмиллиметрового диапазона. In Тезисы докладов VI Российской конференции по физике полупроводников (181).
|
|
|
Aberle, N., & Witte, U. (2003). Deep-sea macrofauna exposed to a simulated sedimentation event in the abyssal NE Atlantic: in situ pulse-chase experiments using 13C-labelled phytodetritus. Mar Ecol Prog Ser, 251, 37–47.
Abstract: Tracer experiments with 13C-labelled diatoms Thalassiosira rotula (Bacillariophycea, 98% 13C-labelled) were conducted at the Porcupine Abyssal Plain (PAP) in the NE Atlantic (BENGAL Station; 48<b0>50'N, 16<b0>30'W, 4850 m depth) during May/June 2000. In situ enrichment experiments were carried out using deep-sea benthic chamber landers: within the chambers a spring bloom was simulated and the fate of this food-pulse within the abyssal macrobenthic community was followed. In focus was the role of different macrofauna taxa and their vertical distribution within the sediment column in consuming and reworking the freshly deposited material. T. rotula is one of the most abundant pelagic diatoms in the NE Atlantic and therefore 0.2 g of freeze dried T. rotula, equivalent to 1 g algal C m-2 yr-1, was injected into each incubation chamber. Three different incubation times of 2.5, 8 and 23 d were chosen in order to follow the uptake of 13C-labelled phytodetritus by macrofauna. After only 2.5 d, 77% of all macrofauna organisms showed tracer uptake. After 23 d the highest degree of enrichment was measured and 95% of the individuals had taken up 13C from the introduced algal material. In addition to that a downward transport of organic matter was observed, even though the mixing was not very intense. The initial processing of carbon was dominated by polychaetes that made up a percentage of 52% of total macrofauna. In general macrofauna organisms that lived close to the sediment surface had higher access to the simulated food-pulse, confirming the hypothesis that individuals close to the sediment surface have the strongest impact on the decomposition of phytodetritus. In our study we observed only modest vertical entrainment of 13C tracers into the sediment. With regard to contradictory results from former 13C-enrichment experiments in bathyal regions, compared to results from our study site in the abyssal plain, we thus propose pronounced differences in feeding strategies between macrofauna communities from continental margins and abyssal plains.
|
|
|
Khosropanah, P. (2003). NbN and NbTiN hot electron bolometer THz mixers. Ph.D. thesis, Chalmers University of Technology, Göteborg.
Abstract: The thesis reports the development of Hot Electron Bolometer (HEB) mixers for radio astronomy heterodyne receivers in THz frequency range. Part of this work is the fabrication of HEB devices, which are based on NbN or NbTiN superconducting thin films (â‰<a4>5 nm). They are integrated with wideband spiral or double-slot planar antennas. The mixer chips are incorporated into a quasi-optical receiver. The experimental part of this work focuses on the characterization of the receiver as a whole, and the HEB mixers as a part. Double side band receiver noise temperature and the IF bandwidth are reported for frequencies from 0.7 THz up to 2.6 THz. The spectrum of the direct response of HEB integrated with dierent antennas are measured using Fourier Transform Spectrometer (FTS). The effect of the bolometer size on total receiver performance and the LO power requirements is also discussed. A high-yield and reliable process for fabrication of NbN HEB mixers have been achieved. Over 100 devices with different bolometer geometry, film property and also different antennas have been fabricated and measured. The measured data enables us to discuss the impact of different parameters to the receiver overall performance.
This work has provided NbN HEB mixers to the following receivers:
TREND (Terahertz REceiver with NbN HEB Device) operating at 1.25-1.5 THz, installed in AST/RO Submillimeter Wave Telescope, Amundsen/Scott South Pole Station, in 2002-2003.
Band 6-low (1.410-1.700 THz) and 6-high (1.700-1.920 THz) of the HIFI (Heterodyne Instrument for Far Infra-red) in the Herschel Space Observatory, due to launch in 2007 by ESA (European Space Agency).
Besides, there has been continuous efforts to develop better models to explain the mixer performance more accurately. They are based on two temperature model for electrons and phonons and solving one-dimensional heat balance equations along the bolometer. The principles of these models are illustrated and the calculated results are compared with measured data.
Keywords: HEB mixer, hot electron bolometer mixer, NbN, NbTiN, superconducting detector, heterodyne receiver, THz mixer, submillimeter mixer, quasioptical receiver, double slot antenna, twin slot antenna, spiral antenna, receiver noise, FTS, Fourier Transform Spectrometer
|
|
|
Tong, C. - Y. E., Meledin, D. V., Marrone, D. P., Paine, S. N., Gibson, H., & Blundell, R. (2003). Near field vector beam measurements at 1 THz. IEEE Microw. Compon. Lett., 13(6), 235–237.
Abstract: We have performed near-field vector beam measurements at 1.03 THz to characterize and align the receiver optics of a superconducting receiver. The signal source is a harmonic generator mounted on an X-Y translation stage. We model the measured two-dimensional complex beam pattern by a fundamental Gaussian mode, from which we derive the position of the beam center, the beam radius and the direction of propagation. By performing scans in the planes separated by 400 mm, we have confirmed that our beam pattern measurements are highly reliable.
|
|
|
Гольцман, Г. Н., & Лудков, Д. Н. (2003). Сверхпроводниковые смесители на горячих электронах терагерцового диапазона и их применение в радиоастрономии. Изв. высших учебных заведений. Радиофизика, 46(8/9).
|
|
|
Kostiuk, T. (2003). Heterodyne spectroscopy in the thermal infrared region: a window on physics and chemistry. In University of Maryland Inn and Conference Center (Ed.), Proc. International Thermal Detectors Workshop (TDW'03), session 7 (Heterodyne detectors). 3501 University Boulevar East Adelphi, MD 20783.
|
|
|
(2003). InSb detectors technical data sheet.
|
|
|
Yagoubov, P. L., Hoogeveen, R. W. M., Maurellis, A. M., Mair, U., Krocka, M., Wagner, G., et al. (2003). TELIS — development of a new balloon borne THz/submm heterodyne limb sounder. In Proc. 14th Int. Symp. Space Terahertz Technol. (pp. 204–214).
Abstract: We present a design concept for a new state-of-the-art balloon borne atmospheric monitor that will allow enhanced limb sounding of the Earth's atmosphere within the submillimeter and far-infrared wavelength spectral range: TELIS, TErahertz and submm LImb Sounder. The instrument is being developed by a consortium of major European institutes that includes the Space Research Organisation of the Netherlands (SRON), the Rutherford Appleton Laboratory (RAL) in the United Kingdom and the Deutschen Zentrum far Luft- und Raumfahrt (DLR) in Germany (lead institute). TELIS will utilise state-of-the-art superconducting heterodyne technology and is designed to be a compact, lightweight instrument capable of providing broad spectral coverage, high spectral resolution and long flight duration (-24 hours duration during a single flight campaign). The combination of high sensitivity and extensive flight duration will allow evaluation of the diurnal variation of key atmospheric constituents such as OH, HO,, C10, BrO together will longer lived constituents such as 0 3 , HCL and N 2 0. Furthermore, TELIS will share a common balloon platform to that of the MIPAS-B Fourier Transform Spectrometer, developed by the Institute of Meteorology and Climate research of the University of Karlsruhe, Germany. MIPAS-B will provide simultaneous and complementary spectral measurements over an extended spectral range. The combination of the TELIS and MIPAS instruments will provide atmospheric scientists with a very powerful observational tool. TELIS will serve as a testbed for new cryogenic heterodyne detection techniques, and as such it will act as a prelude to future spacebome instruments planned by the European Space Agency (ESA).
|
|
|
Baubert, J., Salez, M., Delorme, Y., Pons, P., Goltsman, G., Merkel, H., et al. (2003). Membrane-based HEB mixer for THz applications. In J. - C. Chiao, V. K. Varadan, & C. Cané (Eds.), Proc. SPIE (Vol. 5116, pp. 551–562). SPIE.
Abstract: We report in this paper a new concept for 2.7 THz superconducting Niobium nitride (NbN) Hot-Electron Bolometer mixer (HEB). The membrane process was developped for space telecommnunication applications a few years ago and the HEB mixer concept is now considered as the best choice for low-noise submillimeter-wave frequency heterodyne receivers. The idea is then to join these two technologies. The novel fabrication scheme is to fabricate a NbN HEB mixer on a 1 μm thick stress-less Si3N4/SiO2 membrane. This seems to present numerous improvements concerning : use at higher RF frequencies, power coupling efficiency, HEB mixer sensitivity, noise temperature, and space applications. This work is to be continued within the framework of an ESA TRP project, a 2.7 THz heterodyne camera with numerous applications including a SOFIA airborne receiver. This paper presents the whole fabrication process, the validation tests and preliminary results. Membrane-based HEB mixer theory is currently being investigated and further tests such as heterodyne and Fourier transform spectrometry measurement are planed shortly.
|
|