|
Records |
Links |
|
Author |
Vachtomin, Y. B.; Antipov, S. V.; Maslennikov, S. N.; Smirnov, K. V.; Polyakov, S. L.; Kaurova, N. S.; Grishina, E. V.; Voronov, B. M.; Gol'tsman, G. N. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Noise temperature measurements of NbN phonon-cooled hot electron bolometer mixer at 2.5 and 3.8 THz |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 15th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 15th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
236-241 |
|
|
Keywords ![sorted by Keywords field, ascending order (up)](img/sort_asc.gif) |
HEB mixer, NbN, direct detection effect |
|
|
Abstract |
We present the results of noise temperature measurements of NbN phonon-cooled HEB mixers based on a 3.5 nm NbN film deposited on a high-resistivity Si substrate with a 200 nm – thick MgO buffer layer. The mixer element was integrated with a log-periodic spiral antenna. The noise temperature measurements were performed at 2.5 THz and at 3.8 THz local oscillator frequencies for the 3 µm x 0.2 µm active area devices. The best uncorrected receiver noise temperatures found for these frequencies are 1300 K and 3100 K, respectively. A water vapour discharge laser was used as the LO source. We also present the results of direct detection contribution to the measured Y-factor and of a possible error of noise temperature calculation. This error was more than 8% for the mixer with in-plane dimensions of 2.4 x 0.16 µm 2 at the optimal noise temperature point. The use of a mesh filter enabled us to avoid the effect of direct detection and decrease optical losses by 0.5 dB. The paper is concluded by the investigation results of the mixer polarization response. It was shown that the polarization can differ from the circular one at 3.8 THz by more than 2 dB. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Northampton, Massachusetts, USA |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
344 |
|
Permanent link to this record |
|
|
|
|
Author |
Kroug, M.; Cherednichenko, S.; Choumas, M.; Merkel, H.; Kollberg, E.; Hübers, H.-W.; Richter, H.; Loudkov, D.; Voronov, B.; Gol'Tsman, G. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
HEB quasi-optical heterodyne receiver for THz frequencies |
Type |
Conference Article |
|
Year |
2001 |
Publication |
Proc. 12th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
244-252 |
|
|
Keywords ![sorted by Keywords field, ascending order (up)](img/sort_asc.gif) |
HEB mixer, NbN, MgO, conversion gain bandwidth, noise temperature |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
San Diego, CA, USA |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
319 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Gogidze, I. G.; Gusev, Yu. P.; Elantiev, A. I.; Karasik, B. S.; Semenov, A. D. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Millimeter and submillimeter wave range mixer based on electronic heating of superconducting films in the resistive state |
Type |
Journal Article |
|
Year |
1990 |
Publication |
Sov. Supercond. |
Abbreviated Journal |
Sov. Supercond. |
|
|
Volume |
3 |
Issue |
10 |
Pages |
1582-1597 |
|
|
Keywords ![sorted by Keywords field, ascending order (up)](img/sort_asc.gif) |
HEB mixers |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
240 |
|
Permanent link to this record |
|
|
|
|
Author |
Karasik, B. S.; Elantiev, A. I. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Analysis of the noise performance of a hot-electron superconducting bolometer mixer |
Type |
Conference Article |
|
Year |
1995 |
Publication |
Proc. 6th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 6th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
229-246 |
|
|
Keywords ![sorted by Keywords field, ascending order (up)](img/sort_asc.gif) |
HEB mixers |
|
|
Abstract |
A theoretical analysis for the noise temperature of hot–electron superconducting mixer has been presented. Thecontributions of both Johnson noise and electron temperature fluctuations have been evaluated. A set of criteriaensuring low noise performance of the mixer has been stated and a simple analytic expression for the noisetemperature of the mixer device has been suggested. It has been shown that an improvement of the mixer sensitivitydoes not necessarily follow by a decrease of the bandwidth. An SSB noise temperature limit due to the intrinsic noisemechanisms has been estimated to be as low as 40–90 K for a mixer device made from Nb or NbN thin film.Furthermore, the conversion gain bandwidth can be as wide as is allowed by the intrinsic electron temperaturerelaxation time if an appropriate choice of the mixer resistance has been made. The intrinsic mixer noise bandwidthis of 3 GHz for Nb device and of 5 GHz for NbN device. An additional improvement of the theory has been madewhen a distinction between the impedance measured at high intermediate frequency (larger than the mixerbandwidth) and the mixer ohmic resistance has been taken into account.Recently obtained experimental data on Nb and NbNbolometer mixer devices are viewed in connection with thetheoretical predictions.The noise temperature limit has also been specified for the mixer device where an outdiffusion coolingmechanism rather than the electron–phonon energy relaxation determines the mixer bandwidth. A consideration ofthe noise performance of a bolometer mixer made from YBaCuO film utilizing a hot–electron effect has been done. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Pasadena, Ca |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
258 |
|
Permanent link to this record |
|
|
|
|
Author |
Ozhegov, R. V.; Gorshkov, K. N.; Okunev, O. V.; Gol’tsman, G. N. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Superconducting hot-electron bolometer mixer as element of thermal imager matrix |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Tech. Phys. Lett. |
Abbreviated Journal |
Tech. Phys. Lett. |
|
|
Volume |
36 |
Issue |
11 |
Pages |
1006-1008 |
|
|
Keywords ![sorted by Keywords field, ascending order (up)](img/sort_asc.gif) |
HEB mixers |
|
|
Abstract |
The possibility of using a matrix of sensitive elements on a 12-mm-diameter hyperhemispherical lens in a thermal imager operating in the terahertz range has been studied. Dimensions of a lens region acceptable for arrangement of the matrix, in which the receiver noise temperature varies within 16% of the mean value, are determined to be 3.3% of the lens diameter. Deviations of the main lobe of the directivity pattern are evaluated, which amount to ±1.25° relative to the direction toward the optimum position of a mixer. The fluctuation sensitivity of the receiver measured in experiment is 0.5 K at a frequency of 300 GHz. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1063-7850 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1390 |
|
Permanent link to this record |