Rönnung, F.; Cherednichenko, S.; Winkler, D.; Gol'tsman, G. N. |
Title |
A nanoscale YBCO mixer optically coupled with a bow tie antenna |
Type |
Journal Article |
Year |
1999 |
Publication |
Supercond. Sci. Technol. |
Abbreviated Journal |
Supercond. Sci. Technol. |
Volume |
12 |
Issue |
11 |
Pages |
853-855 |
Keywords |
YBCO HTS HEB mixers |
Abstract |
The bolometric response of YBa2Cu3O7-δ(YBCO) hot-electron bolometers (HEBs) to near-infrared radiation was studied. Devices were fabricated from a 50 nm thick film and had in-plane areas of 10 × 10 µm2, 2 × 0.2 µm2, 1 × 0.2µm2 and 0.5 × 0.2 µm2. We found that nonequilibrium phonons cool down more effectively for the bolometers with smaller area. For the smallest bolometer the bolometric component in the response is 10 dB less than for the largest one. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0953-2048 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1563 |
Permanent link to this record |
|
|
|
Author |
Cherednichenko, S.; Ronnung, F.; Gol'tsman, G.; Gershenzon, E.; Winkler, D. |
Title |
YBa2Cu3O7-δ hot-electron bolometer with submicron dimensions |
Type |
Conference Article |
Year |
1999 |
Publication |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 10th Int. Symp. Space Terahertz Technol. |
Volume |
|
Issue |
|
Pages |
181-189 |
Keywords |
YBCO HTS HEB mixers |
Abstract |
Photoresponse of YBa2Cu3O7-δ hot-electron bolometers to modulated near-infrared radiation was studied at a modulation .frequenc y var y ing from 0.2 MHz to 2 GHz. Bolometers were _fabricated from a 50 12 M thick film and had in-plane areas of 10x10 , um 2 . 2x0.2 s um', 1x0.2 p.m', and 0.5x0.2 jim. We found that nonequilibrium phonons cool down more effectively for the bolometers with smaller area. For the smallest bolometer the bolometric component in the response is 10 dB less than for the largest one. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1572 |
Permanent link to this record |