|
Gershenzon, E. M., Gol’tsman, G. N., Sergeev, A., & Semenov, A. D. (1990). Picosecond response of YBaCuO films to electromagnetic radiation. In W. Gorzkowski, M. Gutowski, A. Reich, & H. Szymczak (Eds.), Proc. European Conf. High-Tc Thin Films and Single Crystals (pp. 457–462).
Abstract: Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., Karasik, B. S., & Semenov, A. D. (1987). Measurement of the energy gap in the compound YBaCu3O9-δ on the basis of the IR absorption spectrum. JETP Lett., 46(5), 237–238.
Abstract: For the first time the long-wave infrared absorption spectrum has been measured by means of the bolometric effect and energy gap for high-temperature superconducting ceramics YBa/sub 2/Cu/sub 3/O/sub 9-delta/ has been determined from absorption threshold. 2delta/kT/sub c/ value is equal to 0.6.
|
|
|
Gol'tsman, G. N., Goghidze, I. G., Kouminov, P. B., Karasik, B. S., Semenov, A. D., & Gershenzon, E. M. (1994). Influence of grain boundary weak links on the nonequilibrium response of YBaCuO thin films to short laser pulses. J. Supercond., 7(4), 751–755.
Abstract: The transient voltage response in both epitaxial and granular YBaCuO thin films to 80 ps pulses of YAG∶Nd laser radiation of wavelength 0.63 and 1.54 μm was studied. In the normal and resistive states both types of films demonstrate two components: a nonequilibrium picosecond component and a bolometric nanosecond one. The normalized amplitudes are almost the same for all films. In the superconducting state we observed a kinetic inductive response and two-component shape after integration. The normalized amplitude of the response in granular films is up to five orders of magnitude larger than in epitaxial films. We interpret the nonequilibrium response in terms of a suppression of the order parameter by the excess of quasiparticles followed by the change of resistance in the normal and resistive states or kinetic inductance in the superconducting state. The sharp rise of inductive response in granular films is explained both by a diminishing of the cross section for current percolation through the disordered network of Josephson weak links and by a decrease of condensate density in neighboring regions.
|
|
|
Danerud, M., Winkler, D., Lindgren, M., Zorin, M., Trifonov, V., Karasik, B., et al. (1994). A fast infrared detector based on patterned YBCO thin film. Supercond. Sci. Technol., 7(5), 321–323.
Abstract: Detectors for infrared radiation ( lambda =0.85 mu m) were made of 50 nm thick YBa2Cu3O7- delta films on LaAlO3 and MgO or 60 nm thick films on NdGaO3. Parallel strips (1 mu m wide by 20 mu m long) were patterned in the films and formed the active device. These devices were designed to detect short infrared laser pulses by electron heating. The detectors were current biased into the resistive and the normal states. The response was studied in direct pulse measurements as well as by amplitude modulation of a laser. The pulse measurements showed a fast picosecond response followed by a slower decay related to phonon escape through the film-substrate interface and heat diffusion in the substrate. The frequency spectra up to 10 GHz showed two slopes with a knee corresponding to the phonon escape time.
|
|
|
Смирнов, А. В., Карманцов, М. С., Смирнов, К. В., Вахтомин, Ю. Б., Мастеров, Д. В., Тархов, М. А., et al. (2012). Терагерцовый отклик болометров на основе тонких пленок YBCO. ЖТФ, 82(12), 108–111.
Abstract: Представлены первые результаты измерения болометрического отклика высокотемпературных сверхпроводниковых детекторов на основе тонких пленок YBCO на электромагнитное излучение с частотой 2.5 THz. Минимальное значение оптической мощности, эквивалентной шуму созданных детекторов, составило 3.5· 10-9 W/sqrt(Hz)sqrt. Обсуждена возможность дальнейшего увеличения чувствительности исследуемых детекторов.
|
|