|
Records |
Links |
|
Author |
Gol'tsman, Gregory; Semenov, Alexei; Smirnov, Konstantin; Voronov, Boris |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Background limited quantum superconducting detector for submillimeter wavelengths |
Type |
Conference Article |
|
Year |
2001 |
Publication |
Proc. 12th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 12th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
469-475 |
|
|
Keywords ![sorted by Keywords field, descending order (down)](img/sort_desc.gif) |
Ti SQD, SQUID readout |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1540 |
|
Permanent link to this record |
|
|
|
|
Author |
Nikoghosyan, A. S.; Martirosyan, R. M.; Hakhoumian, A. A.; Makaryan, A. H.; Tadevosyan, V. R.; Goltsman, G. N.; Antipov, S. V. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Effect of absorption on the efficiency of THz radiation generation in a nonlinear crystal placed into a waveguide |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Armenian J. Phys. |
Abbreviated Journal |
Armenian J. Phys. |
|
|
Volume |
11 |
Issue |
4 |
Pages |
257-262 |
|
|
Keywords ![sorted by Keywords field, descending order (down)](img/sort_desc.gif) |
THz, waveguide, nonlinear crystal |
|
|
Abstract |
The effect of THz radiation absorption on the efficiency of generation of coherent THz radiation in a nonlinear optical crystal placed into a metal rectangular waveguide is studied. The efficiency of the nonlinear conversion of optical laser radiation to the THz band is also a function of the phase-matching (PM) condition inside the nonlinear crystal. The method of partial filling of a metal waveguide with a nonlinear optical crystal is used to ensure phase matching. Phase matching was obtained by the proper choice of the thickness of the nonlinear crystal, namely the degree of partial filling of the waveguide. We have studied the THz radiation attenuation caused by the losses in both the metal walls of the waveguide and in the crystal, taking into account the dimension of the cross section of the waveguide, the degree of partial filling and its dielectric constant. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1829-1171 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1291 |
|
Permanent link to this record |
|
|
|
|
Author |
Nagatsuma, T.; Hirata, A.; Royter, Y.; Shinagawa, M.; Furuta, T.; Ishibashi, T.; Ito, H. |
|
|
Title |
A 120-GHz integrated photonic transmitter |
Type |
Conference Article |
|
Year |
2000 |
Publication |
Proc. International topical meeting on microwave photonics (MWP 2000) |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
225 - 228 |
|
|
Keywords ![sorted by Keywords field, descending order (down)](img/sort_desc.gif) |
THz, teraherts communications, terahertz communication channel, photodiode, transmitter |
|
|
Abstract |
A photonics-based 120-GHz transmitter has been developed. A photodiode, a planar antenna and a silicon lens were integrated to form a compact millimeter-wave (MMW) emitter. The MMW signal emitted from the transmitter has been detected with a waveguide-mounted Schottky diode. The received power exceeded 100 μW, which is the highest value ever reported for photonic MMW transmitter at frequencies of >100 GHz |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
595 |
|
Permanent link to this record |
|
|
|
|
Author |
Gorokhov, G.; Bychanok, D.; Gayduchenko, I.; Rogov, Y.; Zhukova, E.; Zhukov, S.; Kadyrov, L.; Fedorov, G.; Ivanov, E.; Kotsilkova, R.; Macutkevic, J.; Kuzhir, P. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
THz spectroscopy as a versatile tool for filler distribution diagnostics in polymer nanocomposites |
Type |
Journal Article |
|
Year |
2020 |
Publication |
Polymers (Basel) |
Abbreviated Journal |
Polymers (Basel) |
|
|
Volume |
12 |
Issue |
12 |
Pages |
3037 (1 to 14) |
|
|
Keywords ![sorted by Keywords field, descending order (down)](img/sort_desc.gif) |
THz spectroscopy; nanocomposites, percolation threshold, time-domain spectroscopy, time-domain spectrometer, TDS |
|
|
Abstract |
Polymer composites containing nanocarbon fillers are under intensive investigation worldwide due to their remarkable electromagnetic properties distinguished not only by components as such, but the distribution and interaction of the fillers inside the polymer matrix. The theory herein reveals that a particular effect connected with the homogeneity of a composite manifests itself in the terahertz range. Transmission time-domain terahertz spectroscopy was applied to the investigation of nanocomposites obtained by co-extrusion of PLA polymer with additions of graphene nanoplatelets and multi-walled carbon nanotubes. The THz peak of permittivity's imaginary part predicted by the applied model was experimentally shown for GNP-containing composites both below and above the percolation threshold. The physical nature of the peak was explained by the impact on filler particles excluded from the percolation network due to the peculiarities of filler distribution. Terahertz spectroscopy as a versatile instrument of filler distribution diagnostics is discussed. |
|
|
Address |
Institute of Photonics, University of Eastern Finland, Yliopistokatu 7, FI-80101 Joensuu, Finland |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2073-4360 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:33353036; PMCID:PMC7767186 |
Approved |
no |
|
|
Call Number |
|
Serial |
1780 |
|
Permanent link to this record |
|
|
|
|
Author |
Neroev, V. V.; Iomdina, E. N.; Khandzhyan, A. T.; Khodzhabekyan, N. V.; Sengaeva, M. D.; Ivanova, A. V.; Seliverstov, S. V.; Teplyakova, K. O.; Goltsman, G. N. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy |
Type |
Journal Article |
|
Year |
2021 |
Publication |
Vestn. Oftalmol. |
Abbreviated Journal |
Vestn. Oftalmol. |
|
|
Volume |
137 |
Issue |
3 |
Pages |
68-75 |
|
|
Keywords ![sorted by Keywords field, descending order (down)](img/sort_desc.gif) |
THz scanning, cornea, photorefractive keratectomy, medicine |
|
|
Abstract |
Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.
Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.
Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).
Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).
Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
Russian |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1794 |
|
Permanent link to this record |