Records |
Author |
van't Klooster, K.; Myasnikova, S. E.; Parshin, V. V.; Kasparek, W. |
Title |
Results of reflection loss measurements of sample material for radio astronomy telescope antenna for Planck Project |
Type |
Conference Article |
Year |
2004 |
Publication |
Proc. 14th international crimean conference on microwave and telecommunication technology |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
753-755 |
Keywords |
mirror, reflection index, emissivity, Fabry-Perot interferometer, space observatory, terahertz, THz |
Abstract |
Advanced radio telescope antennas for space applications are realised by the use of stable composite materials, which are lighter in general than various metal realisations. Reflectivity measurements have been carried out on high technology samples for the Planck radio telescope. Highly accurate results have been obtained at the Applied Physics Institute in Nizhny Novgorod, and an independent measurement with a totally different setup at the University of Stuttgart confirmed that one of the samples showed a strange behaviour. Moreover, it confirmed the high accuracy of the testing method. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
579 |
Permanent link to this record |
|
|
|
Author |
Shitov, S. V.; Inatani, J.; Shan, W.-L.; Takeda, M; Wang, Z.; Uvarov, A. V.; Ermakov, A. B.; Uzawa, Y. |
Title |
Measurement of emissivity of the ALMA antenna panel at 840 GHz using NbN-based heterodyne SIS receiver |
Type |
Conference Article |
Year |
2008 |
Publication |
Proc. 19th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
263-266 |
Keywords |
SIS mixer, reflection, emissivity, mirror, space telescope, space observatory |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
580 |
Permanent link to this record |
|
|
|
Author |
Kasparek, W; Fernandez, A.; Hollmann, F; Wacker, R. |
Title |
Measurements of ohmic losses of metallic reflectors at 140 GHz using a 3-mirror resonator technique |
Type |
Journal Article |
Year |
2001 |
Publication |
Int. J. Infrared and Millimeter Waves |
Abbreviated Journal |
|
Volume |
22 |
Issue |
11 |
Pages |
1695-1707 |
Keywords |
mirror, reflection index, emissivity, Fabry-Perot interferometer, subterahertz, subTHz |
Abstract |
The reflectivity of metallic mirrors in the millimeter wave region does not only depend on the material, but also on the structure and roughness of the surface. We have performed measurements of the reflectivity of various plane and grooved metallic and graphite samples at 140 GHz. The technique is based on the comparison of the quality factor of a 2-mirror reference resonator with the quality factor of a 3-mirror resonator which has identical dimensions and includes the mirror to be tested. After a brief presentation of the theory, the set-up is described and the reflection loss for various aluminium and copper mirrors as well as vacuum compatible materials for applications in thermonuclear fusion experiments are presented and discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
581 |
Permanent link to this record |
|
|
|
Author |
Myasnikova, S. E.; Parshin, V.V.; van't Klooster, K.; Valsecchi, G. |
Title |
Reflectivity of antenna and mirrors reflectors at 110 and 200 GHz |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. 4th international conference on antenna theory and techniques |
Abbreviated Journal |
|
Volume |
2 |
Issue |
|
Pages |
624- 627 |
Keywords |
mirror, reflection index, emissivity, reflectivity, mirror, Fabry-Perot interferometer, subterahertz, subTHz |
Abstract |
Reflectivity (reflection loss) investigations of nickel samples with different types of surface finish, with and without rhodium coating, have been carried out in the 110-200 GHz frequency range on an installation developed in the Applied Physics Institute of Russia. The reflectivity measurements of high quality silver coated and gold coated mirrors are also presented. The reflectivity (reflection loss) investigations of some carbon fibre samples with and without aluminium coating have been made. Results are interesting, in view of the anisotropy of the carbon fibre material. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
582 |
Permanent link to this record |
|
|
|
Author |
van't Klooster, C. G. M.; Parshin, V. V.; Myasnikova, S. E. |
Title |
Reflectivity of antenna reflectors: measurements at frequencies between 110 and 200 GHz |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. Antennas and propagation society international symposium |
Abbreviated Journal |
|
Volume |
3 |
Issue |
|
Pages |
528-531 |
Keywords |
mirror, reflection index, emissivity, reflectivity, mirror, Fabry-Perot interferometer, subterahertz, subTHz |
Abstract |
It is imperative to test the mechanical, electrical and thermal-optical properties of MM and sub-MM reflector antennas. Electrical, thermal and optical properties are very important and high-accurate measurements lead, obviously, to more accurate results in applications. This paper deals with measurement of electrical reflectivity in the range 110-200 GHz. Reflectivity has been measured for a number of samples, which represent materials used in reflector antennas. Both metal samples and carbon-fibre samples were tested in a dedicated facility available for this purpose at the Applied Physics Institute in Nizhny Novgorod (IAP). The test facility is shortly discussed, with techniques for data extraction. Calibration is done with high quality silver coated mirrors and aluminium control samples. Accurate results have been derived with indicative interesting results. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
583 |
Permanent link to this record |