Tikhonov, V. V., Boyarskii, D. A., Polyakova, O. N., Dzardanov, A. L., & Goltsman, G. N. (2010). Radiophysical and dielectric properties of ore minerals in 12--145 GHz frequency range. PIER B, 25, 349–367.
Abstract: The paper discusses a retrieval technique of complex permittivity of ore minerals in frequency ranges of 12--38 GHz and 77--145 GHz. The method is based on measuring frequency dependencies of transmissivity and reflectivity of plate-parallel mineral samples. In the 12--38 GHz range, the measurements were conducted using a panoramic standing wave ratio and attenuation meter. In the 77--145 GHz range, frequency dependencies of transmissivity and reflectivity were obtained using millimeter-band spectrometer with backward-wave oscillators. The real and imaginary parts of complex permittivity of a mineral were determined solving an equation system for frequency dependencies of transmissivity and reflectivity of an absorbing layer located between two dielectric media. In the course of the work, minerals that are primary ores in iron, zinc, copper and titanium mining were investigated: magnetite, hematite, sphalerite, chalcopyrite, pyrite, and ilmenite.
|
Ozhegov, R. V., Okunev, O. V., Gol’tsman, G. N., Filippenko, L. V., & Koshelets, V. P. (2009). Noise equivalent temperature difference of a superconducting integrated terahertz receiver. J. Commun. Technol. Electron., 54(6), 716–720.
Abstract: The dependence of the noise equivalent temperature difference (NETD) of a superconducting integrated receiver (SIR) on the receiver noise temperature and the inputsignal level has been investigated. An unprecedented NETD of 13±2 mK has been measured at a SIR noise temperature of 200 K, intermediate-frequency bandwidth of 4 GHz, and time constant of 1 s. With a decrease in the input signal, an improvement in the NETD is observed. This effect is explained by a reduction in the influence of the instabilities of the receiver power supply and the amplification circuit that occur when the input signal is decreased.
|
Beck, M., Klammer, M., Lang, S., Leiderer, P., Kabanov, V. V., Gol'tsman, G. N., et al. (2011). Energy-gap dynamics of superconducting NbN thin films studied by time-resolved terahertz spectroscopy. Phys. Rev. Lett., 107(17), 4.
Abstract: Using time-domain terahertz spectroscopy we performed direct studies of the photoinduced suppression and recovery of the superconducting gap in a conventional BCS superconductor NbN. Both processes are found to be strongly temperature and excitation density dependent. The analysis of the data with the established phenomenological Rothwarf-Taylor model enabled us to determine the bare quasiparticle recombination rate, the Cooper pair-breaking rate and the electron-phonon coupling constant, λ=1.1±0.1, which is in excellent agreement with theoretical estimates.
|
Korneeva, Y., Florya, I., Semenov, A., Korneev, A., & Goltsman, G. (2011). New generation of nanowire NbN superconducting single-photon detector for mid-infrared. IEEE Trans. Appl. Supercond., 21(3), 323–326.
Abstract: We present a break-through approach to mid-infrared single-photon detection based on nanowire NbN superconducting single-photon detectors (SSPD). Although SSPD became a mature technology for telecom wavelengths (1.3-1.55 μm) its further expansion to mid-infrared wavelength was hampered by low sensitivity above 2 μm. We managed to overcome this limit by reducing the nanowire width to 50 nm, while retaining high superconducting properties and connecting the wires in parallel to produce a voltage response of sufficient magnitude. The new device exhibits 10 times better quantum efficiency at 3.5 μm wavelength than the “standard” SSPD.
|
Ларионов, П. А., Рябчун, С. А., Финкель, М. И., & Гольцман, Г. Н. (2011). Вывешенный сверхпроводящий детектор терагерцового диапазона. Труды МФТИ, 3(2), 29–30.
Abstract: Рассматриваются технологические особенности создания чувствительного вывешен- ного детектора терагерцевого диапазона на основе плёнки MoRe. Предлагается воз- можный маршрут создания такого детектора и поясняется выбор материалов, ис- пользуемых для создания детектора.
|
Масленникова, А. В., Рябчун, С. А., Финкель, М. И., Каурова, Н. С., Исупова, А. А., Воронов, Б. М., et al. (2011). Широкополосные смесители на горячих электронах на основе NbN наноструктур. Труды МФТИ, 3(2), 31–34.
Abstract: Мы приводим данные исследования полосы преобразования смесителей на горячих электронах (hot-electron bolometer, НЕВ), изготовленных на основе тонких пленок NbN. Зависимость полосы преобразования от длины смесительного элемента находится в прекрасном согласии с результатами теоретической модели HEB-смесителя, в котором энергетическая релаксация электронов одновременно происходит по двум каналам: фононному и диффузионному.
|
Mohan, N., Minaeva, O., Goltsman, G. N., Saleh, M. F., Nasr, M. B., Sergienko, A. V., et al. (2009). Ultrabroadband coherence-domain imaging using parametric downconversion and superconducting single-photon detectors at 1064 nm. Appl. Opt., 48(20), 4009–4017.
Abstract: Coherence-domain imaging systems can be operated in a single-photon-counting mode, offering low detector noise; this in turn leads to increased sensitivity for weak light sources and weakly reflecting samples. We have demonstrated that excellent axial resolution can be obtained in a photon-counting coherence-domain imaging (CDI) system that uses light generated via spontaneous parametric downconversion (SPDC) in a chirped periodically poled stoichiometric lithium tantalate (chirped-PPSLT) structure, in conjunction with a niobium nitride superconducting single-photon detector (SSPD). The bandwidth of the light generated via SPDC, as well as the bandwidth over which the SSPD is sensitive, can extend over a wavelength region that stretches from 700 to 1500 nm. This ultrabroad wavelength band offers a near-ideal combination of deep penetration and ultrahigh axial resolution for the imaging of biological tissue. The generation of SPDC light of adjustable bandwidth in the vicinity of 1064 nm, via the use of chirped-PPSLT structures, had not been previously achieved. To demonstrate the usefulness of this technique, we construct images for a hierarchy of samples of increasing complexity: a mirror, a nitrocellulose membrane, and a biological sample comprising onion-skin cells.
|
Pernice, W., Schuck, C., Li, M., Goltsman, G. N., Sergienko, A. V., & Tang, H. X. (2011). High speed travelling wave single-photon detectors with near-unity quantum efficiency. arXiv, , 1–14.
Abstract: Ultrafast, high quantum efficiency single photon detectors are among the most sought-after elements in modern quantum optics and quantum communication. Close-to-unity photon detection efficiency is essential for scalable measurement-based quantum computation, quantum key distribution, and loophole-free Bell experiments. However, imperfect modal matching and finite photon absorption rates have usually limited the maximum attainable detection efficiency of single photon detectors. Here we demonstrate a superconducting nanowire detector atop nanophotonic waveguides and achieve single photon detection efficiency up to 94% at telecom wavelengths. Our detectors are fully embedded in a scalable, low loss silicon photonic circuit and provide ultrashort timing jitter of 18ps at multi-GHz detection rates. Exploiting this high temporal resolution we demonstrate ballistic photon transport in silicon ring resonators. The direct implementation of such a detector with high quantum efficiency, high detection speed and low jitter time on chip overcomes a major barrier in integrated quantum photonics.
|
Tret’yakov, I. V., Ryabchun, S. A., Kaurova, N. S., Larionov, P. A., Lobastova, A. A., Voronov, B. M., et al. (2010). Optimum absorbed heterodyne power for superconducting NbN hot-electron bolometer mixer. Tech. Phys. Lett., 36(12), 1103–1105.
Abstract: Absorbed heterodyne power has been measured in a low-noise broadband hot-electron bolometer (HEB) mixer for the terahertz range, operating on the effect of electron heating in the resistive state of an ultrathin superconducting NbN film. It is established that the optimum absorbed heterodyne power for the HEB mixer operating at 2.5 THz is about 100 nW.
|
Manova, N. N., Korneeva, Y. P., Korneev, A. A., Slysz, W., Voronov, B. M., & Gol'tsman, G. N. (2011). Superconducting NbN single-photon detector integrated with quarter-wave resonator. Tech. Phys. Lett., 37(5), 469–471.
Abstract: The spectral dependence of the quantum efficiency of superconducting NbN single-photon detectors integrated with quarter-wave resonators based on Si3N4, SiO2, and SiO layers has been studied.
|
Dauler, E., Kerman, A., Robinson, B., Yang, J., Voronov, B., Goltsman, G., et al. (2009). Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors. J. Modern Opt., 56(2), 364–373.
Abstract: A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented.
|
Marsili, F., Bitauld, D., Fiore, A., Gaggero, A., Leoni, R., Mattioli, F., et al. (2009). Superconducting parallel nanowire detector with photon number resolving functionality. J. Modern Opt., 56(2-3), 334–344.
Abstract: We present a new photon number resolving detector (PNR), the Parallel Nanowire Detector (PND), which uses spatial multiplexing on a subwavelength scale to provide a single electrical output proportional to the photon number. The basic structure of the PND is the parallel connection of several NbN superconducting nanowires (100 nm-wide, few nm-thick), folded in a meander pattern. Electrical and optical equivalents of the device were developed in order to gain insight on its working principle. PNDs were fabricated on 3-4 nm thick NbN films grown on sapphire (substrate temperature TS=900C) or MgO (TS=400C) substrates by reactive magnetron sputtering in an Ar/N2 gas mixture. The device performance was characterized in terms of speed and sensitivity. The photoresponse shows a full width at half maximum (FWHM) as low as 660ps. PNDs showed counting performance at 80 MHz repetition rate. Building the histograms of the photoresponse peak, no multiplication noise buildup is observable and a one photon quantum efficiency can be estimated to be QE=3% (at 700 nm wavelength and 4.2 K temperature). The PND significantly outperforms existing PNR detectors in terms of simplicity, sensitivity, speed, and multiplication noise.
|
Третьяков, И. В., Рябчун, С. А., Каурова, Н. С., Ларионов, П. А., Лобастова, А. А., Воронов, Б. М., et al. (2010). Оптимальная поглощенная мощность гетеродина для терагерцового сверхпроводникового NbN смесителя на электронном разогреве. Письма в ЖТФ, 36(23), 78–84.
Abstract: Представлены результаты измерений поглощенной мощности гетеродина малошумящим широкополосным смесителем на эффекте электронного разогрева в резистивном состоянии сверхпроводниковой ультратонкой пленки NbN. Оптимальная поглощенная мощность гетеродина составила около 100 nW на частоте 2.5 THz.
|
Ожегов, Р. В., Горшков, К. Н., Окунев, О. В., & Гольцман, Г. Н. (2010). Сверхпроводниковый смеситель на эффекте электронного разогрева как элемент матрицы системы построения тепловых изображений. Письма в ЖТФ, 36(21), 70–78.
Abstract: Исследована возможность использования матрицы чувствительных элементов на гиперполусферической линзе диаметром 12 mm в тепловизоре терагерцевого диапазона частот. Получены размеры области на линзе, приемлемой для расположения матрицы, в которой шумовая температура приемника меняется в пределах 16% от средней. Диаметр этой области составил 3.3% диаметра линзы.Получены отклонения основного лепестка диаграммы направленности, которые составили ±1.25â—<a6> от направления с оптимальным положением смесителя. Флуктуационная чувствительность приемника в эксперименте составила 0.5 K на частоте 300 GHz.
|
Ozhegov, R. V., Gorshkov, K. N., Gol'tsman, G. N., Kinev, N. V., & Koshelets, V. P. (2011). The stability of a terahertz receiver based on a superconducting integrated receiver. Supercond. Sci. Technol., 24(3), 035003.
Abstract: We present the results of stability testing of a terahertz radiometer based on a superconducting receiver with a SIS tunnel junction as the mixer and a flux-flow oscillator as the local oscillator. In the continuum mode, the receiver with a noise temperature of 95 K at 510 GHz measured over the intermediate frequency (IF) passband of 4-8 GHz offered a noise equivalent temperature difference of 10 ± 1 mK at an integration time of 1 s. We offer a method to significantly increase the integration time without the use of complex measurement equipment. The receiver observed a strong signal over a final detection bandwidth of 4 GHz and offered an Allan time of 5 s.
|