|
Divochiy, A., Misiaszek, M., Vakhtomin, Y., Morozov, P., Smirnov, K., Zolotov, P., et al. (2018). Single photon detection system for visible and infrared spectrum range. Opt. Lett., 43(24), 6085–6088.
Abstract: We demonstrate niobium nitride based superconducting single-photon detectors sensitive in the spectral range 452-2300 nm. The system performance was tested in a real-life experiment with correlated photons generated by means of spontaneous parametric downconversion, where one photon was in the visible range and the other was in the infrared range. We measured a signal to noise ratio as high as 4x10(4) in our detection setting. A photon detection efficiency as high as 64% at 1550 nm and 15% at 2300 nm was observed.
|
|
|
Gorokhov, G., Bychanok, D., Gayduchenko, I., Rogov, Y., Zhukova, E., Zhukov, S., et al. (2020). THz spectroscopy as a versatile tool for filler distribution diagnostics in polymer nanocomposites. Polymers (Basel), 12(12), 3037 (1 to 14).
Abstract: Polymer composites containing nanocarbon fillers are under intensive investigation worldwide due to their remarkable electromagnetic properties distinguished not only by components as such, but the distribution and interaction of the fillers inside the polymer matrix. The theory herein reveals that a particular effect connected with the homogeneity of a composite manifests itself in the terahertz range. Transmission time-domain terahertz spectroscopy was applied to the investigation of nanocomposites obtained by co-extrusion of PLA polymer with additions of graphene nanoplatelets and multi-walled carbon nanotubes. The THz peak of permittivity's imaginary part predicted by the applied model was experimentally shown for GNP-containing composites both below and above the percolation threshold. The physical nature of the peak was explained by the impact on filler particles excluded from the percolation network due to the peculiarities of filler distribution. Terahertz spectroscopy as a versatile instrument of filler distribution diagnostics is discussed.
|
|
|
Karasik, B. S., & Elantiev, A. I. (1995). Analysis of the noise performance of a hot-electron superconducting bolometer mixer. In Proc. 6th Int. Symp. Space Terahertz Technol. (pp. 229–246). Pasadena, Ca.
Abstract: A theoretical analysis for the noise temperature of hot–electron superconducting mixer has been presented. Thecontributions of both Johnson noise and electron temperature fluctuations have been evaluated. A set of criteriaensuring low noise performance of the mixer has been stated and a simple analytic expression for the noisetemperature of the mixer device has been suggested. It has been shown that an improvement of the mixer sensitivitydoes not necessarily follow by a decrease of the bandwidth. An SSB noise temperature limit due to the intrinsic noisemechanisms has been estimated to be as low as 40–90 K for a mixer device made from Nb or NbN thin film.Furthermore, the conversion gain bandwidth can be as wide as is allowed by the intrinsic electron temperaturerelaxation time if an appropriate choice of the mixer resistance has been made. The intrinsic mixer noise bandwidthis of 3 GHz for Nb device and of 5 GHz for NbN device. An additional improvement of the theory has been madewhen a distinction between the impedance measured at high intermediate frequency (larger than the mixerbandwidth) and the mixer ohmic resistance has been taken into account.Recently obtained experimental data on Nb and NbNbolometer mixer devices are viewed in connection with thetheoretical predictions.The noise temperature limit has also been specified for the mixer device where an outdiffusion coolingmechanism rather than the electron–phonon energy relaxation determines the mixer bandwidth. A consideration ofthe noise performance of a bolometer mixer made from YBaCuO film utilizing a hot–electron effect has been done.
|
|
|
Karasik, B. S., & Elantiev, A. I. (1996). Noise temperature limit of a superconducting hot-electron bolometer mixer. Appl. Phys. Lett., 68(6), 853–855.
|
|
|
Karasik, B. S., Il'in, K. S., Pechen, E. V., & Krasnosvobodtsev, S. I. (1996). Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer. Appl. Phys. Lett., 68(16), 2285–2287.
|
|
|
Sergeev, A., & Mitin, V. (2000). Electron-phonon interaction in disordered conductors: Static and vibrating scattering potentials. Phys. Rev. B., 61(9), 6041–6047.
Abstract: Employing the Keldysh diagram technique, we calculate the electron-phonon energy relaxation rate in a conductor with the vibrating and static δ-correlated random electron-scattering potentials. If the scattering potential is completely dragged by phonons, this model yields the Schmid’s result for the inelastic electron-scattering rate τ−1e−ph. At low temperatures the effective interaction decreases due to disorder, and τ−1e−ph∝T4l (l is the electron mean-free path). In the presense of the static potential, quantum interference of numerous scattering processes drastically changes the effective electron-phonon interaction. In particular, at low temperatures the interaction increases, and τ−1e−ph∝T2/l. Along with an enhancement of the interaction, which is observed in disordered metallic films and semiconducting structures at low temperatures, the suggested model allows us to explain the strong sensitivity of the electron relaxation rate to the microscopic quality of a particular film.
|
|
|
Gershenson, M. E., Gong, D., Sato, T., Karasik, B. S., & Sergeev, A. V. (2001). Millisecond electron-phonon relaxation in ultrathin disordered metal films at millikelvin temperatures. Appl. Phys. Lett., 79, 2049–2051.
|
|
|
Tong, C. - Y. E., Meledin, D. V., Marrone, D. P., Paine, S. N., Gibson, H., & Blundell, R. (2003). Near field vector beam measurements at 1 THz. IEEE Microw. Compon. Lett., 13(6), 235–237.
Abstract: We have performed near-field vector beam measurements at 1.03 THz to characterize and align the receiver optics of a superconducting receiver. The signal source is a harmonic generator mounted on an X-Y translation stage. We model the measured two-dimensional complex beam pattern by a fundamental Gaussian mode, from which we derive the position of the beam center, the beam radius and the direction of propagation. By performing scans in the planes separated by 400 mm, we have confirmed that our beam pattern measurements are highly reliable.
|
|
|
Cao, A., Jiang, L., Chen, S. H., Antipov, S. V., & Shi, S. C. (2007). IF gain bandwidth of a quasi-optical NbN superconducting HEB mixer. In Proc. International conference on microwave and millimeter wave technology (pp. 1–3). Builin.
Abstract: In this paper, the intermediate frequency (IF) gain bandwidth of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer is investigated at 500 GHz with an IF system incorporating with a frequency down-converting scheme which is able to sweep the IF signal in a frequency range of 0.3-4 GHz. The IF gain bandwidth of the device is measured to be 1.5 GHz when it is biased at a voltage of the minimum noise temperature, and becomes larger when the bias voltage increases.
|
|
|
Финкель, М. И. (2006). Терагерцовые смесители на эффекте электронного разогрева в ультратонких плёнках NbN и NbTiN. Ph.D. thesis, , .
|
|