Stevens, M., Hadfeld, R., Schwall, R., Nam, S. W., & and Mirin, R. (2006). Quantum dot single photon sources studied with superconducting single photon detectors. IEEE J. Sel. Topics Quantum Electron., 12(6), 1255–1267.
|
Wang, Z., Miki, S., & Fujiwara, M. (2009). Superconducting nanowire single-photon detectors for quantum information and communications. IEEE J. Sel. Topics Quantum Electron., 15(6), 1741–1747.
Abstract: Superconducting nanowire single-photon detectors (SNSPDs or SSPD) are highly promising devices in the growing field of quantum information and communications technology. We have developed a practical SSPD system with our superconducting thin films and devices fabrication, optical coupling packaging, and cryogenic technology. The SSPD system consists of six-channel SSPD devices and a compact Gifford-McMahon (GM) cryocooler, and can operate continuously on 100 V ac power without the need for any cryogens. The SSPD devices were fabricated from high-quality niobium nitride (NbN) ultrathin films that were epitaxially grown on single-crystal MgO substrates. The packaged SSPD devices were temperature stabilized to 2.96 K ± 10 mK. The system detection efficiency for an SSPD device with an area of 20 × 20 ¿m2 was found to be 2.6% and 4.5% at wavelengths of 1550 and 1310 nm, respectively, at a dark count rate of 100 Hz, and a jitter of 100 ps full-width at half maximum. We also performed ultrafast BB84 quantum key distribution (QKD) field testing and entanglement-based QKD experiments using these SSPD devices.
|
Gonzalez, F. J., Ilic, B., Alda, J., & Boreman, G. D. (2005). Antenna-coupled infrared detectors for imaging applications. IEEE J. Sel. Topics Quantum Electron., 11(1), 117–120.
Abstract: Infrared focal plane arrays (IRFPAs) are a critical component in advanced infrared imaging systems. IRFPAs are made up of two parts, a detector array and a readout integrated circuit (ROIC) multiplexer. Current ROIC technology has typical pitch sizes of 20×20 to 50×50 μm2. In order to make antenna-coupled detectors suited for infrared imaging systems, two-dimensional (2-D) arrays have been fabricated that cover a whole pixel area with the penalty of increasing the noise figure of the detector and, therefore, reducing its performance. By coupling a Fresnel zone plate lens to a single element antenna-coupled detector, infrared radiation can be collected over a typical pixel area and still keep low-noise levels. A Fresnel zone plate lens coupled to a single-element square-spiral-coupled infrared detector has been fabricated and its performance compared to single element antenna-coupled detectors and 2-D arrays of antenna coupled detectors. Measurements made at 10.6 μm showed a two-order-of-magnitude increase in SNR and a ~× increase in D* as compared to 2-D arrays of antenna-coupled detectors.
|