toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Dickert, Franz L. url  doi
openurl 
  Title Christoph A. Schalley (Ed.): Analytical methods in supramolecular chemistry Type Journal Article
  Year 2007 Publication Analytical and Bioanalytical Chemistry Abbreviated Journal Anal Bioanal Chem  
  Volume 389 Issue 7-8 Pages 2039-2040  
  Keywords supramolecular recognition  
  Abstract This is a review of book.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1618-2642 ISBN Medium (up)  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 563  
Permanent link to this record
 

 
Author Lieberzeit, Peter A.; Dickert, Franz L. url  doi
openurl 
  Title Chemosensors in environmental monitoring: challenges in ruggedness and selectivity Type Journal Article
  Year 2009 Publication Analytical and Bioanalytical Chemistry Abbreviated Journal Anal Bioanal Chem  
  Volume 393 Issue 2 Pages 467-472  
  Keywords environmental monitoring, in situ sensing, artificial recognition materials, real-life application, molecular imprinting, QCM  
  Abstract Environmental analysis is a potential key application for chemical sensors owing to their inherent ability to detect analytes on-line and in real time in distributed systems. Operating a chemosensor in a natural environment poses substantial challenges in terms of ruggedness, long-term stability and calibration. This article highlights current trends of achieving both the necessary selectivity and ruggedness: one way is deploying sensor arrays consisting of robust broadband sensors and extracting information via chemometrics. If using only a single sensor is desired, molecularly imprinted polymers offer a straightforward way for designing artificial recognition materials. Molecularly imprinted polymers can be utilized in real-life environments, such as water and air, aiming at detecting analytes ranging from small molecules to entire cells.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1618-2642 ISBN Medium (up)  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 564  
Permanent link to this record
 

 
Author Rodriguez-Morales, F.; Zannoni, R.; Nicholson, J.; Fischetti, M.; Yngvesson, K. S.; Appenzeller, J. url  doi
openurl 
  Title Direct and heterodyne detection of microwaves in a metallic single wall carbon nanotube Type Journal Article
  Year 2006 Publication Applied Physics Letters Abbreviated Journal Appl. Phys. Lett.  
  Volume 89 Issue 8 Pages 083502  
  Keywords carbon nanotube, GHz heterodyne detector, direct detector  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-6951 ISBN Medium (up)  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 565  
Permanent link to this record
 

 
Author Fu, K.; Zannoni, R.; Chan, C.; Adams, S. H.; Nicholson, J.; Polizzi, E.; Yngvesson, K. S. url  doi
openurl 
  Title Terahertz detection in single wall carbon nanotubes Type Journal Article
  Year 2008 Publication Applied Physics Letters Abbreviated Journal Appl. Phys. Lett.  
  Volume 92 Issue 3 Pages 033105  
  Keywords HEB, single wall, carbon nanotube, CNT, SWNT, SWCNT, terahertz detection, THz  
  Abstract It is reported that terahertz radiation from 0.69 to 2.54 THz has been sensitively detected in a device consisting of bundles of carbon nanotubes containing single wall metallic carbon nanotubes, quasioptically coupled through a lithographically fabricated antenna, and a silicon lens. The measured data are consistent with a bolometric detection process in the metallic tubes and the devices show promise for operation well above 4.2 K.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-6951 ISBN Medium (up)  
  Area Expedition Conference  
  Notes NEP is not shown Approved no  
  Call Number Serial 566  
Permanent link to this record
 

 
Author Parrott, Edward P. J.; Zeitler, J. Axel; Fris<cc><152>c<cc><152>ic<cc><81>, Tomislav; Pepper, Michael; Jones, William; Day, Graeme M.; Gladden, Lynn F. url  doi
openurl 
  Title Testing the sensitivity of terahertz spectroscopy to changes in molecular and supramolecular structure: a study of structurally similar cocrystals Type Journal Article
  Year 2009 Publication Crystal Growth & Design Abbreviated Journal Crystal Growth & Design  
  Volume 9 Issue 3 Pages 1452-1460  
  Keywords supramolecular recognition, infrared, terahertz, IR, THz, TDS  
  Abstract Terahertz time-domain-spectroscopy (THz-TDS) has emerged as a versatile spectroscopic technique, and an alternative to powder X-ray diffraction in the characterization of molecular crystals. We tested the ability of terahertz spectroscopy to distinguish between chiral and racemic hydrogen-bonded cocrystals that are similar in molecular and supramolecular structure. Terahertz spectroscopy readily distinguished between the isostructural cocrystals of theophylline with chiral and racemic forms of malic acid which are almost identical in molecular structure and supramolecular architecture. Similarly, the cocrystals of theophylline with chiral and racemic forms of tartaric acid, which are similar at the molecular level but dissimilar in crystal packing, were distinguished unequivocally. The investigation of the same cocrystals using X-ray powder diffraction and Raman spectroscopy suggested that THz-TDS is comparable in sensitivity to diffraction methods and more sensitive than Raman spectroscopy to changes in cocrystal architecture. The differences in spectra acquired by THz-TDS could be further enhanced by cooling the samples to 109 K.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1528-7483 ISBN Medium (up)  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 567  
Permanent link to this record
Select All    Deselect All
 |   | 