Galeazzi, M. (2011). Fundamental noise processes in TES devices. IEEE Trans. Appl. Supercond., 21(3), 267–271.
Abstract: Microcalorimeters and bolometers are noise-limited devices, therefore, a proper understanding of all noise sources is essential to predict and interpret their performance. In this paper, I review the fundamental noise processes contributing to Transition Edge Sensor (TES) microcalorimeters and bolometers and their effect on device performance. In particular, I will start with a simple, monolithic device model, moving to a more complex one involving discrete components, to finally move to today's more realistic, comprehensive model. In addition to the basic noise contribution (equilibrium Johnson noise and phonon noise), TES are significantly affected by extra noise, which is commonly referred to as excess noise. Different fundamental processes have been proposed and investigated to explain the origin of this excess noise, in particular near equilibrium non-linear Johnson noise, flux-flow noise, and internal thermal fluctuation noise. Experimental evidence shows that all three processes are real and contribute, at different levels, to the TES noise, although different processes become important at different regimes. It is therefore time to discard the term “excess noise” and consider these terms part of the “fundamental noise processes” instead.
|
Tol, J. van, Brunel, L. - C., & Wylde, R. J. (2005). A quasioptical transient electron spin resonance spectrometer operating at 120 and 240 GHz. Rev. Sci. Instrum., 76(7), 074101 (1 to 8).
Abstract: A new multifrequency quasioptical electron paramagnetic resonance (EPR) spectrometer is described. The superheterodyne design with Schottky diode mixer/detectors enables fast detection with subnanosecond time resolution. Optical access makes it suitable for transient EPR (TR-EPR) at 120 and 240 GHz. These high frequencies allow for an accurate determination of small g-tensor anisotropies as are encountered in excited triplet states of organic molecules like porphyrins and fullerenes. The measured concentration sensitivity for continuous-wave (cw) EPR at 240 GHz and at room temperature without cavity is 1013 spins/cm3 (15 nM) for a 1 mT linewidth and a 1 Hz bandwidth. With a Fabry-Perot cavity and a sample volume of 30 nl, the sensitivity at 240 GHz corresponds to [approximate]3×109 spins for a 1 mT linewidth. The spectrometer's performance is illustrated with applications of transient EPR of excited triplet states of organic molecules, as well as cw EPR of nitroxide reference systems and a thin film of a colossal magnetoresistance material.
|
Karasik, B. S., & Elantiev, A. I. (1996). Noise temperature limit of a superconducting hot-electron bolometer mixer. Appl. Phys. Lett., 68(6), 853–855.
|
Kroug, M., Cherednichenko, S., Choumas, M., Merkel, H., Kollberg, E., Hübers, H. - W., et al. (2001). HEB quasi-optical heterodyne receiver for THz frequencies. In Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 244–252). San Diego, CA, USA.
|
Archer, J. W. (1983). Multiple mixer, cryogenic receiver for 200-350 GHz. Rev. Sci. Instrum., 54(10), 1371–1376.
Abstract: This paper describes a new 200–350-GHz dual polarization heterodyne radiometer receiver for radio astronomy applications. The receiver incorporates four pairs of cryogenically cooled Schottky-barrier diode single-ended mixers, each pair covering a 30–40-GHz subband of the full operating band. Each mixer, with its IF amplifier, is mounted in an individual cryogenic subdewar comprising a separate vcuum chamber and a cold stage, which may be readily thermally connected to or disconnected from the main refrigerator by a novel mechanical heat switch. A dual polarization LO diplexer is mounted on a rotary table above the subdewars. For band selection, the two diplexer rf output ports may be positioned over any of the four pairs of subdewars. The SSB receiver noise temperatues achieved are less than 500 K between 200 and 240 GHz, less than 800 K between 245 and 275 GHz and 1500 K at 345 GHz.
|