Gol’tsman, G., Okunev, O., Chulkova, G., Lipatov, A., Dzardanov, A., Smirnov, K., et al. (2001). Fabrication and properties of an ultrafast NbN hot-electron single-photon detector. IEEE Trans. Appl. Supercond., 11(1), 574–577.
Abstract: A new type of ultra-high-speed single-photon counter for visible and near-infrared wavebands based on an ultrathin NbN hot-electron photodetector (HEP) has been developed. The detector consists of a very narrow superconducting stripe, biased close to its critical current. An incoming photon absorbed by the stripe produces a resistive hotspot and causes an increase in the film’s supercurrent density above the critical value, leading to temporary formation of a resistive barrier across the device and an easily measurable voltage pulse. Our NbN HEP is an ultrafast (estimated response time is 30 ps; registered time, due to apparatus limitations, is 150 ps), frequency unselective device with very large intrinsic gain and negligible dark counts. We have observed sequences of output pulses, interpreted as single-photon events for very weak laser beams with wavelengths ranging from 0.5 /spl mu/m to 2.1 /spl mu/m and the signal-to-noise ratio of about 30 dB.
|
Hovenier J.N., Adam A.J.L., Kašalynas I., Gao J.R., Klaassen T.O., Baryshev A., et al. (2006). Phase-locking on the beat signal of a two-mode 2.7 terahertz metal-metal quantum cascade laser. In Proc. Symp. IEEE/LEOS Benelux Chapter (pp. 125–128).
Abstract: We have studied the linewidth and phase-locking of a 2.7 THz quantum cascade laser by using a superconducting bolometer mixer. The 8 GHz beat signal is compared with a microwave reference with a feedback to the laser bias current. Phase locking has been demonstrated, resulting in an extremely narrow beat linewidth of less than 10 Hz. Under frequency-stabilization conditions we find that the line profile is virtually Lorentzian with a long-term minimum linewidth of the THz modes of about 6.3 kHz. Temperature dependent measurements suggestthat this linewidthdoes not approach the Schawlow-Townes limit.
|
Meledin D., Pantaleev M., Pavolotsky A., Risacher C., Robles V.A.P., Belitsky V., et al. (2004). Design of a balanced waveguide HEB mixer for APEX 1.32 THz receiver. In Proc. 15th Int. Symp. Space Terahertz Technol. (pp. 211–217).
Abstract: The prototype of a waveguide balanced Hot Electron Bolometer (HEB) Terahertz mixer is designed as a part of development for the APEX Project of Band T2 receiver for 1250-1390 GHz. The proposed mixer employs balanced scheme with two identical HEB devices. These individual mixers would be placed on two separate crystalline quartz substrates with dimensions of 1000μm x67μm x17 μm each with integrated RF choke filters, DC-bias and IF circuitry. A 3 dB quadrature waveguide directional coupler is needed to provide local oscillator (LO) injection and RF signal distribution between the two HEB mixers. We have designed the coupler to achieve the required frequency band, low insertion loss and symmetrical division of the RF and LO power within the band of interest. Initial design of HEB mixer layout is developed based on a previous development for a 345 GHz sideband separation mixer. We present also results of development of microfabrication technology of the waveguide hybrid employing micromachining approach combined with electroplating technique.
|
Belitsky, V., Desmaris, V., Dochev, D., Meledin, D., & Pavolotsky, A. (2011). Towards Multi-Pixel Heterodyne Terahertz Receivers. In Proc. 22th Int. Symp. Space Terahertz Technol..
Abstract: Terahertz multi-pixel heterodyne receivers introduce multiple challenges for their implementation, mostly due to the extremely small dimensions of all components and even smaller tolerances in terms of alignment, linear dimensions and waveguide component surface quality. In this manuscript, we present a concept of terahertz multi-pixel heterodyne receiver employing optical layout using polarization split between the LO and RF. The frontend isbased on a waveguide balanced HEB mixer for the frequency band 1.6 – 2.0 THz. The balanced HEB mixer followsthe layout of earlier demonstrated APEX T2 mixer. However for the mixer presented here, we implemented split-block layout offering inimized lengths of all waveguides and thus reducing the associated RF loss. The micromachining methods employed for producing the mixer housing and the HEB mixer chip are very suitable for producing multiple structures and hence are in-line with requirements of multi-pixel receiver technology. The demonstrated relatively simple mounting of the mixer chip with self-aligning should greatly facilitate the integration of such multi-channel receiver. Index Terms—Instrumentation, Multi-pixel, Terahertz, Waveguide Balanced Mixer.
|
Verevkin, A., Zhang, J., Slysz, W., Sobolewski, R., Lipatov, A., Okunev, O., et al. (2002). Spectral sensitivity and temporal resolution of NbN superconducting single-photon detectors. In Proc. 13th Int. Symp. Space Terahertz Technol. (pp. 105–111).
Abstract: We report our studies on spectral sensitivity and time resolution of superconducting NbN thin film single-photon detectors (SPDs). Our SPDs exhibit an everimentally measured detection efficiencies (DE) from — 0.2% at 2=1550 nm up to —3% at lambda=405 nm wavelength for 10-nm film thickness devices and up to 3.5% at lambda=1550 nm for 3.5-nm film thickness devices. Spectral dependences of detection efficiency (DE) at 2=0.4 —3.0 pm range are presented. With variable optical delay setup, it is shown that NbN SPD potentially can resolve optical pulses with the repetition rate up to 10 GHz at least. The observed full width at the half maximum (FWHM) of the signal pulse is about 150-180 ps, limited by read-out electronics. The jitter of NbN SPD is measured to be —35 ps at optimum biasing.
|