Neroev, V. V., Iomdina, E. N., Khandzhyan, A. T., Khodzhabekyan, N. V., Sengaeva, M. D., Ivanova, A. V., et al. (2021). Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy. Vestn. Oftalmol., 137(3), 68–75.
Abstract: Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.
Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.
Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).
Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).
Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
|
Smirnov, K., Moshkova, M., Antipov, A., Morozov, P., & Vakhtomin, Y. (2021). The cascade switching of the photon number resolving superconducting single-photon detectors. IEEE Trans. Appl. Supercond., 31(2), 1–4.
Abstract: In this article, present the first detailed study of cascade switching in superconducting photon number resolving detectors. The detectors were made in the form of four parallel nanowires, coupled with the single-mode optical fiber and mounted into a closed-cycle refrigerator with a temperature of 2.1 K. We found out the value of additional false pulses (N cas.sw. ) appearing due to cascade switching and showed that it is possible to set up the detector bias current that corresponds to a high level of the detection efficiency and a low level of N cas.sw. simultaneously. We reached the detection efficiency of 60% and N cas.sw. = 0.3%.
|
Zhang, X., Lita, A. E., Smirnov, K., Liu, H. L., Zhu, D., Verma, V. B., et al. (2020). Strong suppression of the resistivity near the superconducting transition in narrow microbridges in external magnetic fields. Phys. Rev. B, 101(6), 060508 (1 to 6).
Abstract: We have investigated a series of superconducting bridges based on homogeneous amorphous WSi and MoSi films, with bridge widths w ranging from 2 to 1000μm and film thicknesses d∼4−6 and 100 nm. Upon decreasing the bridge widths below the respective Pearl lengths, we observe in all cases distinct changes in the characteristics of the resistive transitions to superconductivity. For each of the films, the resistivity curves R(B,T) separate at a well-defined and field-dependent temperature T∗(B) with decreasing the temperature, resulting in a dramatic suppression of the resistivity and a sharpening of the transitions with decreasing bridge width w. The associated excess conductivity in all the bridges scales as 1/w, which may suggest either the presence of a highly conducting region that is dominating the electric transport, or a change in the vortex dynamics in narrow enough bridges. We argue that this effect can only be observed in materials with sufficiently weak vortex pinning.
|
Lobanov, Y. V., Vakhtomin, Y. B., Pentin, I. V., Khabibullin, R. A., Shchavruk, N. V., Smirnov, K. V., et al. (2018). Characterization of the THz quantum cascade laser using fast superconducting hot electron bolometer. EPJ Web Conf., 195, 04004 (1 to 2).
|
Smirnov, A. V., Karmantsov, M. S., Smirnov, K. V., Vakhtomin, Y. B., Masterov, D. V., Tarkhov, M. A., et al. (2012). Terahertz response of thin-film YBCO bolometers. Tech. Phys., 57(12), 1716–1719.
Abstract: The bolometric response of high-temperature thin-film YBCO superconducting detectors to an electromagnetic radiation with a frequency of 2.5 THz is measured for the first time. The minimum value of the noise-equivalent power of the detectors is 3.5 × 10−9 W/Hz−−−√. The feasibility of further increasing the sensitivity of the detectors is discussed.
|
Казаков, А. Ю., Селиверстов, С. В., Дивочий, А. В., Смирнов, К. В., Финкель, М. И., & Вахтомин, Ю. Б. (2012). Возможность применения сверхпроводниковых материалов в качестве отражающего покрытия зеркала телескопа, предназначенного для наблюдений анизотропии реликтового излучения. Преподаватель ХХI век, (3), 221–224.
Abstract: В статье исследуется возможность использования сверхпроводящего материала в качестве отражающего слоя зеркала субмиллиметрового телескопа, охлажденного до криогенных температур и предназначенного для наблюдений реликтового излучения. Для нескольких сверхпроводниковых материалов вычислен диапазон частот, в котором флуктуации теплового излучения покрытия меньше флуктуаций источника. Показана перспективность применения покрытия из Nb3Ge.
|
Семенов, А. В., Корнеев, А. А., Лобанов, Ю. В., Корнеева, Ю. П., Рябчун, С. А., Третьяков, И. В., et al. (2012). Оценка поляризационных искажений, вносимых оптической системой радиотелескопа миллиметрового диапазона. Преподаватель ХХI век, (4), 230–236.
Abstract: В статье рассмотрена поляризация электромагнитного поля вблизи фокальной точки телескопической системы. Оценена верхняя граница поляризационных искажений, вносимых отражающими поверхностями, в том числе с учетом неидеальности отражения.
|
Семенов, А. В., Корнеев, А. А., Смирнов, А. В., Смирнов, К. В., Ожегов, Р. В., Окунев, О. В., et al. (2012). Линейные по мощности поглощаемого излучения поправки к спектральным функциям «грязного» сверхпроводника и отклик сверхпроводниковых детекторов. Преподаватель ХХI век, (3), 216–220.
Abstract: В статье развит метод расчета малых поправок к спектральным функциям пленки «грязного» сверхпроводника, возникающих под действием поглощаемой мощности электромагнитного излучения. Метод пригоден в случае спектральных функций произвольного вида, что позволяет применять его для расчета отклика сверхпроводниковых детекторов излучения различного типа.
|
Корнеева, Ю. П., Трифонов, А. В., Вахтомин, Ю. Б., Смирнов, К. В., Корнеев, А. А., Рябчун, С. А., et al. (2012). Расчет согласующего оптического резонатора для сверхпроводникового нанополоскового детектора. Преподаватель ХХI век, (3), 225–227.
Abstract: В статье произведен расчет резонатора, предназначенного для согласования сверхпроводникового нанополоскового однофотонного детектора с оптическим сигналом. Показано, что для детектора, выполненного из пленки с типичным сопротивлением квадрата 500 Ом и коэффициентом заполнения 0.5 коэффициент согласования с излучением, поляризованным параллельно полоскам детектора, достигает величины около 60%.
|
Смирнов, А. В., Карманцов, М. С., Смирнов, К. В., Вахтомин, Ю. Б., Мастеров, Д. В., Тархов, М. А., et al. (2012). Терагерцовый отклик болометров на основе тонких пленок YBCO. ЖТФ, 82(12), 108–111.
Abstract: Представлены первые результаты измерения болометрического отклика высокотемпературных сверхпроводниковых детекторов на основе тонких пленок YBCO на электромагнитное излучение с частотой 2.5 THz. Минимальное значение оптической мощности, эквивалентной шуму созданных детекторов, составило 3.5· 10-9 W/sqrt(Hz)sqrt. Обсуждена возможность дальнейшего увеличения чувствительности исследуемых детекторов.
|