Гершензон, Е. М., Гольцман, Г. Н., Елантьев, А. И., Кагане, М. Л., Мултановский, В. В., & Птицина, Н. Г. (1983). Применение субмиллиметровой ЛОВ спектроскопии для определения химической природы и концентрации примесей в чистых полупроводниках. Физика и техника полупроводников, 17(8), 1430–1437.
|
Iomdina, E. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., Rusova, A. A., & Goltsman, G. N. (2018). Terahertz scanning for evaluation of corneal and scleral hydration. STM, 10(4), 143–149.
Abstract: The aim of the investigation was to study the prospects of using continuous THz scanning of the cornea and the sclera to determine water concentration in these tissues and on the basis of the obtained data to develop the experimental installation for monitoring corneal and scleral hydration degree.Materials and Methods. To evaluate corneal and scleral transmittance and reflectance spectra in the THz range, the developed experimental installations were used to study 3 rabbit corneas and 3 scleras, 2 whole rabbit eyes, and 3 human scleras. Besides, two rabbit eyes were studied in vivo prior to keratorefractive surgery as well as 10 and 21 days following the surgery (LASIK).Results. There have been created novel experimental installations enabling in vitro evaluation of frequency dependence of corneal and scleral transmittance coefficients and reflectance coefficients on water percentage in the THz range. Decrease in corneal water content by 1% was found to lead to reliably established decrease in the reflected signal by 13%. The reflectance spectrum of the whole rabbit eye was measured in the range of 0.13–0.32 THz. The study revealed the differences between the indices of rabbit cornea and sclera, as well as rabbit and human sclera. There was developed a laboratory model of the installation for in vivo evaluation of corneal and scleral hydration using THz radiation.Conclusion. The preliminary findings show that the proposed technique based on the use of continuous THz radiation can be employed to create a device for noninvasive control of corneal and scleral hydration.
|
Gershenson, E. M., Gol'tsman, G. N., Elant'ev, A. I., Kagane, M. L., Multanovskii, V. V., & Ptitsina, N. G. (1983). Use of submillimeter backward-wave tube spectroscopy in determination of the chemical nature and concentration of residual impurities in pure semiconductors. Sov. Phys. Semicond., 17(8), 908–913.
|
Gershenzon, E. M., Gol'tsman, G. N., & Ptitsina, N. G. (1973). Submillimeter spectroscopy of semiconductors. Sov. Phys. JETP, 37(2), 299–304.
Abstract: The possibility is considered of carrying out submillimeter-wave spectral investigations of semiconductors by means of a high resolution spectrometer with backward-wave tubes. Results of a study of the excitation spectra of small impurities, D-(A +) centers and free excitons in germanium are presented.
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Mirskij, G. I., & Semenov, A. D. (1991). Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution. Pribory i Tekhnika Eksperimenta, 34(2), 125–131.
Abstract: The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
|