Elezov, M. S., Ozhegov, R. V., Kurochkin, Y. V., Goltsman, G. N., Makarov, V. S., Samartsev, V. V., et al. (2015). Countermeasures against blinding attack on superconducting nanowire detectors for QKD. In EPJ Web Conf. (Vol. 103, 10002 (1 to 2)).
Abstract: Nowadays, the superconducting single-photon detectors (SSPDs) are used in Quantum Key Distribution (QKD) instead of single-photon avalanche photodiodes. Recently bright-light control of the SSPD has been demonstrated. This attack employed a “backdoor” in the detector biasing technique. We developed the autoreset system which returns the SSPD to superconducting state when it is latched. We investigate latched state of the SSPD and define limit conditions for effective blinding attack. Peculiarity of the blinding attack is a long nonsingle photon response of the SSPD. It is much longer than usual single photon response. Besides, we need follow up response duration of the SSPD. These countermeasures allow us to prevent blind attack on SSPDs for Quantum Key Distribution.
|
Elezov, M. S., Ozhegov, R. V., Goltsman, G. N., & Makarov, V. (2017). Development of the experimental setup for investigation of latching of superconducting single-photon detector caused by blinding attack on the quantum key distribution system. In EPJ Web of Conferences (Vol. 132, 2).
Abstract: Recently bright-light control of the SSPD has been
demonstrated. This attack employed a “backdoor†in the detector biasing
scheme. Under bright-light illumination, SSPD becomes resistive and
remains “latched†in the resistive state even when the light is switched off.
While the SSPD is latched, Eve can simulate SSPD single-photon response
by sending strong light pulses, thus deceiving Bob. We developed the
experimental setup for investigation of a dependence on latching threshold
of SSPD on optical pulse length and peak power. By knowing latching
threshold it is possible to understand essential requirements for
development countermeasures against blinding attack on quantum key
distribution system with SSPDs.
|
Goltsman, G. N., Samartsev, V. V., Vinogradov, E. A., Naumov, A. V., & Karimullin, K. R. (2015). New generation of superconducting nanowire single-photon detectors. In EPJ Web of Conferences (Vol. 103, 01006 (1 to 2)).
Abstract: We present an overview of recent results for new generation of infrared and optical superconducting nanowire single-photon detectors (SNSPDs) that has already demonstrated a performance that makes them devices-of-choice for many applications. SNSPDs provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, SNSPDs are also compatible with an integrated optical platform as a crucial requirement for applications in emerging quantum photonic technologies. By embedding SNSPDs in nanophotonic circuits we realize waveguide integrated single photon detectors which unite all desirable detector properties in a single device.
|
Florya, I. N., Korneeva, Y. P., Sidorova, M. V., Golikov, A. D., Gaiduchenko, I. A., Fedorov, G. E., et al. (2015). Energy relaxtation and hot spot formation in superconducting single photon detectors SSPDs. In EPJ Web of Conferences (Vol. 103, 10004 (1 to 2)).
Abstract: We have studied the mechanism of energy relaxation and resistive state formation after absorption of a single photon for different wavelengths and materials of single photon detectors. Our results are in good agreement with the hot spot model.
|
Fedorov, G. E., Gaiduchenko, I. A., Golikov, A. D., Rybin, M. G., Obraztsova, E. D., Voronov, B. M., et al. (2015). Response of graphene based gated nanodevices exposed to THz radiation. In EPJ Web of Conferences (Vol. 103, 10003 (1 to 2)).
Abstract: In this work we report on the response of asymmetric graphene based devices to subterahertz and terahertz radiation. Our devices are made in a configuration of a field-effect transistor with conduction channel between the source and drain electrodes formed with a CVD-grown graphene. The radiation is coupled through a spiral antenna to source and top gate electrodes. Room temperature responsivity of our devices is close to the values that are attractive for commercial applications. Further optimization of the device configuration may result in appearance of novel terahertz radiation detectors.
|
Wild, W., Kardashev, N. S., Likhachev, S. F., Babakin, N. G., Arkhipov, V. Y., Vinogradov, I. S., et al. (2009). Millimetron—a large Russian-European submillimeter space observatory. Exp. Astron., 23(1), 221–244.
Abstract: Millimetron is a Russian-led 12 m diameter submillimeter and far-infrared space observatory which is included in the Space Plan of the Russian Federation for launch around 2017. With its large collecting area and state-of-the-art receivers, it will enable unique science and allow at least one order of magnitude improvement with respect to the Herschel Space Observatory. Millimetron will be operated in two basic observing modes: as a single-dish observatory, and as an element of a ground-space very long baseline interferometry (VLBI) system. As single-dish, angular resolutions on the order of 3 to 12 arc sec will be achieved and spectral resolutions of up to a million employing heterodyne techniques. As VLBI antenna, the chosen elliptical orbit will provide extremely large VLBI baselines (beyond 300,000 km) resulting in micro-arc second angular resolution.
|
Tiulina, V., Iomdina, E., Goltsman, G., Seliverstov, S., Sianosyan, A., Teplyakova, K., et al. (2019). UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo (Vol. 9).
Abstract: Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for noninvasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 161500255.
|
Voevodin, E. I., Gershenzon, E. M., Goltsman, G. N., Ptitsina, N. G., & Chulkova, G. M. (1988). Capture of free holes by charged acceptors in uniaxially deformed Ge. Fizika i Tekhnika Poluprovodnikov, 22(3), 540–543.
Abstract: Цель настоящей работы — исследование кинетики примесной фотопроводимости p-Ge при сильном одноосном сжатии в широком диапазоне изменения интенсивности примесного подсвета, создающего свободные дырки, и определение сечения каскадного захвата дырок на мелкие заряженные акцепторы в условиях преобладания электрон-фононного механизма потерь энергии.
|
Minaeva, O., Fraine, A., Korneev, A., Divochiy, A., Goltsman, G., & Sergienko, A. (2012). High resolution optical time-domain reflectometry using superconducting single-photon detectors. In Frontiers in Opt. 2012/Laser Sci. XXVIII (Fw3a.39). Optical Society of America.
Abstract: We discuss the advantages and limitations of single-photon optical time-domain reflectometry with superconducting single-photon detectors. The higher two-point resolution can be achieved due to superior timing performance of SSPDs in comparison with InGaAs APDs.
|
Matyushkin, Y., Kaurova, N., Voronov, B., Goltsman, G., & Fedorov, G. (2020). On chip carbon nanotube tunneling spectroscopy. Fullerenes, Nanotubes and Carbon Nanostructures, 28(1), 50–53.
Abstract: We report an experimental study of the band structure of individual carbon nanotubes (SCNTs) based on investigation of the tunneling density of states, i.e. tunneling spectroscopy. A common approach to this task is to use a scanning tunneling microscope (STM). However, this approach has a number of drawbacks, to overcome which, we propose another method – tunneling spectroscopy of SCNTs on a chip using a tunneling contact. This method is simpler, cheaper and technologically advanced than the STM. Fabrication of a tunnel contact can be easily integrated into any technological route, therefore, a tunnel contact can be used, for example, as an additional tool in characterizing any devices based on individual CNTs. In this paper we demonstrate a simple technological procedure that results in fabrication of good-quality tunneling contacts to carbon nanotubes.
|