Semenov, A. D., Hübers, H. - W., Gol’tsman, G. N., & Smirnov, K. (2002). Superconducting quantum detector for astronomy and X-ray spectroscopy. In J. Pekola, B. Ruggiero, & P. Silvestrini (Eds.), Proc. Int. Workshop on Supercond. Nano-Electronics Devices (pp. 201–210). Boston, MA: Springer.
Abstract: We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array.
|
Hübers, H. W., Pavlov, S. G., Semenov, A. D., Tredicucci, A., Köhler, R., Mahler, L., et al. (2005). Investigation of a 2.5 THz quantum cascade laser as local oscillator. In Proc. 16th Int. Symp. Space Terahertz Technol. (18). Göteborg, Sweden.
|
Mair, U., Suttywong, N., Hübers, H. - W., Semenov, A. D., Richter, H., Wagner, G., et al. (2005). Development of 1.8 THz receiver for the TELIS instrument. In Proc. 16th Int. Symp. Space Terahertz Technol.. Göteborg, Sweden.
|
Gershenzon, E. M., Goltsman, G. N., Semenov, A. D., & Sergeev, A. V. (1989). Limiting characteristic of fast superconducting bolometers. Sov. Phys.-Tech. Phys., 34, 195–199.
Abstract: Теоретически и экспериментально исследовано физическое ограничение быстродействия сверхпроводящего болометра. Показано, что минимальная постоянная времени реализуется в условиях электронного разогрева и определяется процессом неупругого электрон-фонон- ного взаимодействия. Сформулированы требования кконструкции «электронного болометра» для достижения предельной чувствительности. Проведено сравнение характеристик электронного болометра и обычных болометров различных типов.
|
Gershenzon, E. M., Gershenzon, M. E., Goltsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Wide-band highspeed Nb and YBaCuO detectors. IEEE Trans. Magn., 27(2), 2836–2839.
Abstract: The physical limitations on the response time and the nature of nonequilibrium detection of radiation were investigated for Nb and YBCO film in a wide spectral range from millimeter to near-infrared wavelengths. In the case of ideal heat removal from the film, the detection mechanism is connected with an electron heating effect which is not selective over a wide spectral interval. For Nb, the dependence of the response time on the electron mean free path l and temperature T is tau varies as T/sup -2/l/sup -1/. The values of detectivity D* and tau are 3*10/sup 11/ W/sup -1/ Hz/sup 1/2/ cm and 5*10/sup -9/ s at T=1.6 K, respectively. For YBCO film the tau value of 1-2 ps at T=77 K was obtained; the NEP value of 3*10/sup -11/ W-Hz/sup -1/2/ can be obtained at T=77 K in the case of the optimal film matching to the radiation.
|