Shcherbatenko, M., Lobanov, Y., Semenov, A., Kovalyuk, V., Korneev, A., Ozhegov, R., et al. (2017). Coherent detection of weak signals with superconducting nanowire single photon detector at the telecommunication wavelength. In I. Prochazka, R. Sobolewski, & R. B. James (Eds.), Proc. SPIE (Vol. 10229, 0G (1 to 12)). Spie.
Abstract: Achievement of the ultimate sensitivity along with a high spectral resolution is one of the frequently addressed problems, as the complication of the applied and fundamental scientific tasks being explored is growing up gradually. In our work, we have investigated performance of a superconducting nanowire photon-counting detector operating in the coherent mode for detection of weak signals at the telecommunication wavelength. Quantum-noise limited sensitivity of the detector was ensured by the nature of the photon-counting detection and restricted by the quantum efficiency of the detector only. Spectral resolution given by the heterodyne technique and was defined by the linewidth and stability of the Local Oscillator (LO). Response bandwidth was found to coincide with the detector’s pulse width, which, in turn, could be controlled by the nanowire length. In addition, the system noise bandwidth was shown to be governed by the electronics/lab equipment, and the detector noise bandwidth is predicted to depend on its jitter. As have been demonstrated, a very small amount of the LO power (of the order of a few picowatts down to hundreds of femtowatts) was required for sufficient detection of the test signal, and eventual optimization could lead to further reduction of the LO power required, which would perfectly suit for the foreseen development of receiver matrices and the need for detection of ultra-low signals at a level of less-than-one-photon per second.
|
|
|
Korneev, A., Kovalyuk, V., Ferrari, S., Kahl, O., Pernice, W., An, P., et al. (2017). Superconducting Single-Photon Detectors for Integrated Nanophotonics Circuits. In 16th ISEC (pp. 1–3).
Abstract: We present an overview of our recent achievements in integration of superconducting nanowire single-photon detectors SNSPD with dielectric optical waveguides. We are able to produce complex nanophotonics integrated circuits containing optical elements and photon detector on single chip thus producing a compact integrated platform for quantum optics applications.
|
|
|
Korneev, A., Kovalyuk, V., An, P., Golikov, A., Zubkova, E., Ferrari, S., et al. (2018). Superconducting single-photon detector for integrated waveguide spectrometer. In EPJ Web Conf. (Vol. 190, 04009).
Abstract: We present our recent achievements in the development of an on-chip spectrometer consisting of arrayed waveguide grating made of Si3N4 waveguides and NbN superconducting single-photon detector.
|
|
|
Kovalyuk, V., Kahl, O., Ferrari, S., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2018). On-chip single-photon spectrometer for visible and infrared wavelength range. In J. Phys.: Conf. Ser. (Vol. 1124, 051045).
Abstract: Here we show our latest progress in the field of a single-photon spectrometer for the visible and infrared wavelengths ranges implementation. We consider three different on-chip approaches: a coherent spectrometer with a low power of the heterodyne, a coherent spectrometer with a high power of the heterodyne, and an eight-channel single-photon spectrometer for direct detection. Along with high efficiency, spectrometers show high detection efficiency and temporal resolution through the use of waveguide integrated superconducting nanowire single-photon detectors.
|
|
|
Prokhodtsov, A., An, P., Kovalyuk, V., Zubkova, E., Golikov, A., Korneev, A., et al. (2018). Optimization of on-chip photonic delay lines for telecom wavelengths. In J. Phys.: Conf. Ser. (Vol. 1124, 051052).
Abstract: In this work, we experimentally studied optical delay lines on silicon nitride platform for telecomm wavelength (1550 nm). We modeled the group delay time and fabricated spiral optical delay lines with different waveguide widths and radii as well as measured their transmission. For the half etched rib waveguides we achieved the losses in the range of 3 dB/cm.
|
|