Sidorova, M. V., Divochiy, A. V., Vakhtomin, Y. B., & Smirnov, K. V. (2015). Ultrafast superconducting single-photon detector with a reduced active area coupled to a tapered lensed single-mode fiber. J. Nanophoton., 9(1), 093051.
Abstract: This paper presents an ultrafast niobium nitride (NbN) superconducting single-photon detector (SSPD) with an active area of 3×3 μm2 that offers better timing performance metrics than the previous SSPD with an active area of 7×7 μm2. The improved SSPD demonstrates a record timing jitter (<25 ps), an ultrashort recovery time (<2 ns), an extremely low dark count rate, and a high detection efficiency in a wide spectral range from visible part to near infrared. The record parameters were obtained due to the development of a new technique providing effective optical coupling between a detector with a reduced active area and a standard single-mode telecommunication fiber. The advantages of the new approach are experimentally confirmed by taking electro-optical measurements.
|
|
|
Shcheslavskiy, V., Morozov, P., Divochiy, A., Vakhtomin, Y., Smirnov, K., & Becker, W. (2016). Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector. Rev. Sci. Instrum., 87, 053117 (1 to 5).
Abstract: Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ~5% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.
|
|
|
Semenov, A. V., Devyatov, I. A., Ryabchun, S. A., Maslennikov, S. N., Maslennikova, A. S., Larionov, P. A., et al. (2011). Absorption of terahertz electromagnetic radiation in dirty superconducting film at arbitrary type of the spectral functions. Rus. J. Radio Electron., (10).
Abstract: A problem of absorption of high-frequency electromagnetic field in dirty superconductor is treated within Keldysh technic. Expression for the source term in the kinetic equation for quasiparticle distribution function is derived. The result is significant for deriving a consistent microscopic theory of superconducting detectors for terahertz frequency range, perspective detectors on kinetic inductance of current-biased superconducting strip and on Josephson inductance of tunnel.
|
|
|
Anosov, A. A., Nemchenko, O. Y., Less, Y. A., Kazanskii, A. S., & Mansfel'd, A. D. (2015). Possibilities of acoustic thermometry for controlling targeted drug delivery. Acoust. Phys., 61(4), 488–493.
Abstract: Model acoustic thermometry experiments were conducted during heating of an aqueous liposome suspension. Heating was done to achieve the liposome phase transition temperature. At the moment of the phase transition, the thermal acoustic signal achieved a maximum and decreased, despite continued heating. During subsequent cooling of the suspension, when lipids again passed through the phase transition point, the thermal acoustic signal again increased, despite a reduction in temperature. This effect is related to an increase in ultrasound absorption by the liposome suspension at the moment of the lipid phase transition. The result shows that acoustic thermography can be used to control targeted delivery of drugs mixed in thermally sensitive liposomes, the integrity of which is violated during heating to the phase transition temperature.
|
|
|
Anosov, A. A., Barabanenkov, Y. N., Kazanskii, A. S., Less, Y. A., & Sharakshane, A. S. (2009). The inverse problem of acoustothermography with correlation reception of thermal acoustic radiation. Acoust. Phys., 55(1), 114–119.
Abstract: For the one-dimensional inverse problem of acoustothermography with correlation reception of thermal acoustic radiation, an integral equation is presented and experimentally verified. A method of solving the inverse problem is proposed. The method is based on combining the correlation functions of thermal acoustic radiation that were obtained for different distances between the receivers.
|
|
|
Лесс, Ю. А., & Кирсанов, Ю. А. (2015). Былое и думы. Посвящение эпохе Н. Н. Малова, Е. М. Гершензона, В. С. Эткина.
|
|
|
Флоря, И. Н. (2009). Ультрабыстрый однофотонный детектор для оптических применений. In Науч. сессия МИФИ (pp. 45–46).
Abstract: Представлен сверхпроводниковый однофотонный детектор (SSPD) на основе ультратонкой пленки NbN, обладающий рекордным быстродействием. Активный элемент выполнен в виде N сверхпроводящих полосок соединенных параллельно, покрывающих площадку размером 10 мкм х 10 мкм. Для SSPD с N=12 длительность импульса напряжения составляет 200 пс. Полученные результаты открывают путь к детекторам обладающими скоростью счета свыше 1 ГГц, что делает SSPDs весьма привлекательными во многих применениях, в частности для квантовой криптографии. SSPD хорошо согласуется с оптоволокном и легко может быть интегрирован в полностью готовую для работы приемную систему.
|
|
|
Семенов, А. В. (2010). Проскальзывание фазы, поглощение электромагнитного излучения и формирование отклика в детекторах на основе узких полосок сверхпроводников. Ph.D. thesis, , .
|
|
|
Baeva, E. M., Titova, N. A., Kardakova, A. I., Piatrusha, S. U., & Khrapai, V. S. (2020). Universal bottleneck for thermal relaxation in disordered metallic films. Jetp Lett., 111(2), 104–108.
Abstract: We study the heat relaxation in current biased metallic films in the regime of strong electron–phonon coupling. A thermal gradient in the direction normal to the film is predicted, with a spatial temperature profile determined by the temperature-dependent heat conduction. In the case of strong phonon scattering, the heat conduction occurs predominantly via the electronic system and the profile is parabolic. This regime leads to the linear dependence of the noise temperature as a function of bias voltage, in spite of the fact that all the dimensions of the film are large compared to the electron–phonon relaxation length. This is in stark contrast to the conventional scenario of relaxation limited by the electron–phonon scattering rate. A preliminary experimental study of a 200-nm-thick NbN film indicates the relevance of our model for materials used in superconducting nanowire single-photon detectors.
|
|
|
Rasulova, G. K., Brunkov, P. N., Pentin, I. V., Kovalyuk, V. V., Gorshkov, K. N., Kazakov, A. Y., et al. (2011). Mutual synchronization of two coupled self-oscillators based on GaAs/AlGaAs superlattices. Tech. Phys., 56(6), 826–830.
Abstract: The interaction of self-oscillators based on 30-period weakly coupled GaAs/AlGaAs superlattices is studied. The action of one self-oscillator on the other was observed for a constant bias voltage in the absence of generation of self-sustained oscillations in one of the oscillators. It is shown that induced oscillations in a forced oscillator appear due to excitation of oscillations in the system of coupled oscillators forming the electric-field domain wall at the frequency of one of the higher harmonics of a forcing oscillation.
|
|