|
Ozhegov, R. V., Okunev, O. V., Gol’tsman, G. N., Filippenko, L. V., & Koshelets, V. P. (2009). Noise equivalent temperature difference of a superconducting integrated terahertz receiver. J. Commun. Technol. Electron., 54(6), 716–720.
Abstract: The dependence of the noise equivalent temperature difference (NETD) of a superconducting integrated receiver (SIR) on the receiver noise temperature and the inputsignal level has been investigated. An unprecedented NETD of 13±2 mK has been measured at a SIR noise temperature of 200 K, intermediate-frequency bandwidth of 4 GHz, and time constant of 1 s. With a decrease in the input signal, an improvement in the NETD is observed. This effect is explained by a reduction in the influence of the instabilities of the receiver power supply and the amplification circuit that occur when the input signal is decreased.
|
|
|
Ozhegov, R. V., Gorshkov, K. N., Smirnov, K. V., Gol’tsman, G. N., Filippenko, L. V., & Koshelets, V. P. (2010). Terahertz imaging system based on superconducting integrated receiver. In Proc. 2-nd Int. Conf. Terahertz and Microwave radiation: Generation, Detection and Applications (pp. 20–22).
Abstract: The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Developing an array of SIRs would allow obtaining amplitude and phase characteristics of incident radiation in the plane of the receiver. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compare to traditional systems: i) high temperature resolution, comparable to the best results for incoherent receivers; ii) high spectral resolution allowing spectral analysis of various substances; iii) the local oscillator frequency can be varied to obtain images at different frequencies, effectively providing “color” images; iv) since a heterodyne receiver preserves the phase of the radiation, it is possible to construct 3D images. The paper presents a prototype THz imaging system using an 1 pixel SIR. We have studied the dependence of the noise equivalent temperature difference (NETD) on the integration time and also possible ways of achieving best possible sensitivity. An NETD of 13 mK was obtained with an integration time of 1 sec a detection bandwidth of 4 GHz at a local oscillator frequency of 520 GHz. An important advantage of an FFO is its wide operation range: 300-700 GHz.
|
|
|
Zinoni, C., Alloing, B., Li, L. H., Marsili, F., Fiore, A., Lunghi, L., et al. (2007). Single-photon experiments at telecommunication wavelengths using nanowire superconducting detectors. Appl. Phys. Lett., 91(3), 031106 (1 to 3).
Abstract: The authors report fiber-coupled superconducting single-photon detectors with specifications that exceed those of avalanche photodiodes, operating at telecommunication wavelength, in sensitivity, temporal resolution, and repetition frequency. The improved performance is demonstrated by measuring the intensity correlation function g(2)(τ) of single-photon states at 1300nm produced by single semiconductor quantum dots.
This work was supported by Swiss National Foundation through the “Professeur borsier” and NCCR Quantum Photonics program, FP6 STREP “SINPHONIA” (Contract No. NMP4-CT-2005-16433), IP “QAP” (Contract No. 15848), NOE “ePIXnet,” and the Italian MIUR-FIRB program.
|
|
|
Zinoni, C., Alloing, B., Li, L. H., Marsili, F., Fiore, A., Lunghi, L., et al. (2010). Erratum: “Single photon experiments at telecom wavelengths using nanowire superconducting detectors” [Appl. Phys. Lett. 91, 031106 (2007)]. Appl. Phys. Lett., 96(8), 089901.
Abstract: A calculation error was made in the original publication of this letter. The error was in the calculation of the noise equivalent power (NEP) values for the avalanche photodiode detector (APD) and the superconducting single photon detector (SSPD), the incorrect values were plotted on the right axis in Fig. 1(b). The correct NEP values were calculated with the same equation reported in the original letter and the revised Fig. 1(b) is shown below. The other conclusions of the paper remain unaltered.
|
|
|
Ozhegov, R. V., Gorshkov, K. N., Okunev, O. V., & Gol’tsman, G. N. (2010). Superconducting hot-electron bolometer mixer as element of thermal imager matrix. Tech. Phys. Lett., 36(11), 1006–1008.
Abstract: The possibility of using a matrix of sensitive elements on a 12-mm-diameter hyperhemispherical lens in a thermal imager operating in the terahertz range has been studied. Dimensions of a lens region acceptable for arrangement of the matrix, in which the receiver noise temperature varies within 16% of the mean value, are determined to be 3.3% of the lens diameter. Deviations of the main lobe of the directivity pattern are evaluated, which amount to ±1.25° relative to the direction toward the optimum position of a mixer. The fluctuation sensitivity of the receiver measured in experiment is 0.5 K at a frequency of 300 GHz.
|
|