|
Тархов, М. А. (2016). Разработка сверхпроводниковых однофотонных детекторов с повышенной спектральной чувствительностью и быстродействием. Автореферат.
|
|
|
Shcheslavskiy, V., Morozov, P., Divochiy, A., Vakhtomin, Y., Smirnov, K., & Becker, W. (2016). Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector. Rev. Sci. Instrum., 87, 053117 (1 to 5).
Abstract: Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ~5% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.
|
|
|
Gupta, D., & Kadin, A. M. (1999). Single-photon-counting hotspot detector with integrated RSFQ readout electronics. IEEE Trans. Appl. Supercond., 9(2), 4487–4490.
Abstract: Absorption of an infrared photon in an ultrathin film (such as 10-nm NbN) creates a localized nonequilibrium hotspot on the submicron length scale and sub-ns time scale. If a strip /spl sim/1 /spl mu/m wide is biased in the middle of the superconducting transition, this hotspot will lead to a resistance pulse with amplitude proportional to the energy of the incident photon. This resistance pulse, in turn, can be converted to a current pulse and inductively coupled to a SQUID amplifier with a digitized output, operating at 4 K or above. A preliminary design analysis indicates that this data can be processed on-chip, using ultrafast RSFQ digital circuits, to obtain a sensitive infrared detector for wavelengths up to 10 /spl mu/m and beyond, with bandwidth of 1 GHz, that counts individual photons and measures their energy with 25 meV resolution. This proposed device combines the speed of a hot-electron bolometer with the single-photon-counting ability of a transition-edge microcalorimeter, to obtain an infrared detector with sensitivity, speed, and spectral selectivity that are unmatched by any alternative technology.
|
|
|
Steudle, G. A., Schietinger, S., Höckel, D., Dorenbos, S. N., Zadeh, I. E., Zwiller, V., et al. (2012). Measuring the quantum nature of light with a single source and a single detector. Phys. Rev. A, 86(5), 053814.
Abstract: An elementary experiment in optics consists of a light source and a detector. Yet, if the source generates nonclassical correlations such an experiment is capable of unambiguously demonstrating the quantum nature of light. We realized such an experiment with a defect center in diamond and a superconducting detector. Previous experiments relied on more complex setups, such as the Hanbury Brown and Twiss configuration, where a beam splitter directs light to two photodetectors, creating the false impression that the beam splitter is a fundamentally required element. As an additional benefit, our results provide a simplification of the widely used photon-correlation techniques.
|
|
|
Takemoto, K., Nambu, Y., Miyazawa, T., Sakuma, Y., Yamamoto, T., Yorozu, S., et al. (2015). Quantum key distribution over 120 km using ultrahigh purity single-photon source and superconducting single-photon detectors. Sci. Rep., 5, 14383.
Abstract: Advances in single-photon sources (SPSs) and single-photon detectors (SPDs) promise unique applications in the field of quantum information technology. In this paper, we report long-distance quantum key distribution (QKD) by using state-of-the-art devices: a quantum-dot SPS (QD SPS) emitting a photon in the telecom band of 1.5 μm and a superconducting nanowire SPD (SNSPD). At the distance of 100 km, we obtained the maximal secure key rate of 27.6 bps without using decoy states, which is at least threefold larger than the rate obtained in the previously reported 50-km-long QKD experiment. We also succeeded in transmitting secure keys at the rate of 0.307 bps over 120 km. This is the longest QKD distance yet reported by using known true SPSs. The ultralow multiphoton emissions of our SPS and ultralow dark count of the SNSPD contributed to this result. The experimental results demonstrate the potential applicability of QD SPSs to practical telecom QKD networks.
|
|
|
Ferrari, S., Kovalyuk, V., Hartmann, W., Vetter, A., Kahl, O., Lee, C., et al. (2017). Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors. Opt. Express, 25(8), 8739–8750.
Abstract: We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.
|
|
|
Korneev, A., Golt'sman, G., & Pernice, W. (2015). Photonic integration meets single-photon detection (Vol. 51).
Abstract: By embedding superconducting nanowire single-photon detectors (SNSPDs) in nanophotonic circuits, these waveguide-integrated detectors are a key building block for future on-chip quantum computing applications.
|
|
|
Kovalyuk, V., Ferrari, S., Kahl, O., Semenov, A., Shcherbatenko, M., Lobanov, Y., et al. (2017). On-chip coherent detection with quantum limited sensitivity. Sci Rep, 7(1), 4812.
Abstract: While single photon detectors provide superior intensity sensitivity, spectral resolution is usually lost after the detection event. Yet for applications in low signal infrared spectroscopy recovering information about the photon's frequency contributions is essential. Here we use highly efficient waveguide integrated superconducting single-photon detectors for on-chip coherent detection. In a single nanophotonic device, we demonstrate both single-photon counting with up to 86% on-chip detection efficiency, as well as heterodyne coherent detection with spectral resolution f/f exceeding 10(11). By mixing a local oscillator with the single photon signal field, we observe frequency modulation at the intermediate frequency with ultra-low local oscillator power in the femto-Watt range. By optimizing the nanowire geometry and the working parameters of the detection scheme, we reach quantum-limited sensitivity. Our approach enables to realize matrix integrated heterodyne nanophotonic devices in the C-band wavelength range, for classical and quantum optics applications where single-photon counting as well as high spectral resolution are required simultaneously.
|
|
|
Kovalyuk, V., Ferrari, S., Kahl, O., Semenov, A., Lobanov, Y., Shcherbatenko, M., et al. (2017). Waveguide integrated superconducting single-photon detector for on-chip quantum and spectral photonic application. In J. Phys.: Conf. Ser. (Vol. 917, 062032).
Abstract: With use of the travelling-wave geometry approach, integrated superconductor- nanophotonic devices based on silicon nitride nanophotonic waveguide with a superconducting NbN-nanowire suited on top of the waveguide were fabricated. NbN-nanowire was operated as a single-photon counting detector with up to 92 % on-chip detection efficiency in the coherent mode, serving as a highly sensitive IR heterodyne mixer with spectral resolution (f/df) greater than 106 in C-band at 1550 nm wavelength
|
|
|
Манова, Н. Н., Корнеева, Ю. П., & Корнеев, А. А., Гольцман, Г. Н. (2010). Cверхпроводящий однофотонный детектор, интегрированный с оптическим резонатором. In Науч. сессия НИЯУ МИФИ (pp. 92–93).
|
|
|
Корнеева, Ю. П., Флоря, И. Н., Корнеев, А. А., & Гольцман, Г. Н. (2010). Cверхпроводящий однофотонный детектор для дальнего ИК диапазона длин волн. In Науч. сессия НИЯУ МИФИ (pp. 46–47).
Abstract: Мы представляем быстродействующий сверхпроводниковый однофотонный детектор (SSPD) для дальнего инфракрасного диапазона на основе ультратонкой монокристаллической пленки NbN толщиной 3 нм, состоящий из параллельных полосок. QE на длине волны 1,5.μм и 1,3 μм для предложенного SSPD практически одинаковы. SSPD показывает отклик длительностью 200 пс, что открывает путь к детекторам, обладающим скоростью счета свыше 1 ГГц.
|
|
|
Флоря, И. Н. (2009). Ультрабыстрый однофотонный детектор для оптических применений. In Науч. сессия МИФИ (pp. 45–46).
Abstract: Представлен сверхпроводниковый однофотонный детектор (SSPD) на основе ультратонкой пленки NbN, обладающий рекордным быстродействием. Активный элемент выполнен в виде N сверхпроводящих полосок соединенных параллельно, покрывающих площадку размером 10 мкм х 10 мкм. Для SSPD с N=12 длительность импульса напряжения составляет 200 пс. Полученные результаты открывают путь к детекторам обладающими скоростью счета свыше 1 ГГц, что делает SSPDs весьма привлекательными во многих применениях, в частности для квантовой криптографии. SSPD хорошо согласуется с оптоволокном и легко может быть интегрирован в полностью готовую для работы приемную систему.
|
|
|
Семенов, А. В. (2010). Проскальзывание фазы, поглощение электромагнитного излучения и формирование отклика в детекторах на основе узких полосок сверхпроводников. Ph.D. thesis, , .
|
|
|
Elezov, M. S., Semenov, A. V., An, P. P., Tarkhov, M. A., Goltsman, G. N., Kardakova, A. I., et al. (2013). Investigating the detection regimes of a superconducting single-photon detector. J. Opt. Technol., 80(7), 435.
Abstract: The detection regimes of a superconducting single-photon detector have been investigated. A technique is proposed for determining the regions in which “pure regimes” predominate. Based on experimental data, the dependences of the internal quantum efficiency on the bias current are determined in the one-, two-, and three-photon detection regimes.
|
|
|
Ferrari, S., Kovalyuk, V., Vetter, A., Lee, C., Rockstuhl, C., Semenov, A., et al. (2019). Analysis of the detection response of waveguide-integrated superconducting nanowire single-photon detectors at high count rate. Appl. Phys. Lett., 115(10), 101104.
Abstract: Nanophotonic circuitry and superconducting nanowires have been successfully combined for detecting single photons, propagating in an integrated photonic circuit, with high efficiency and low noise and timing uncertainty. Waveguide-integrated superconducting nanowire single-photon detectors (SNSPDs) can nowadays be engineered to achieve subnanosecond recovery times and can potentially be adopted for applications requiring Gcps count rates. However, particular attention shall be paid to such an extreme count rate regime since artifacts in the detector functionality emerge. In particular, a count-rate dependent detection efficiency has been encountered that can compromise the accuracy of quantum detector tomography experiments. Here, we investigate the response of waveguide-integrated SNSPDs at high photon flux and identify the presence of parasitic currents due to the accumulation of charge in the readout electronics to cause the above-mentioned artifact in the detection efficiency. Our approach allows us to determine the maximum photon count rate at which the detector can be operated without adverse effects. Our findings are particularly important to avoid artifacts when applying SNSPDs for quantum tomography.
We acknowledge support through ERC Consolidator Grant No. 724707 and from the Deutsche Forschungsgemeinschaft through Project No. PE 1832/5-1,2, as well as funding by the Volkswagen Foundation. This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie Grant Agreement No. 675745. V.K. and G.G. acknowledge support from the Russian Science Foundation Project No. 16-12-00045 (NbN film deposition and testing). A.V. acknowledges support from the Karlsruhe School of Optics and Photonics (KSOP).
|
|