Korneev, A., Divochiy, A., Marsili, F., Bitauld, D., Fiore, A., Seleznev, V., et al. (2008). Superconducting photon number resolving counter for near infrared applications. In P. Tománek, D. Senderáková, & M. Hrabovský (Eds.), Proc. SPIE (Vol. 7138, 713828 (1 to 5)). Spie.
Abstract: We present a novel concept of photon number resolving detector based on 120-nm-wide superconducting stripes made of 4-nm-thick NbN film and connected in parallel (PNR-SSPD). The detector consisting of 5 strips demonstrate a capability to resolve up to 4 photons absorbed simultaneously with the single-photon quantum efficiency of 2.5% and negligibly low dark count rate.
|
Minaeva, O., Fraine, A., Korneev, A., Divochiy, A., Goltsman, G., & Sergienko, A. (2012). High resolution optical time-domain reflectometry using superconducting single-photon detectors. In Frontiers in Opt. 2012/Laser Sci. XXVIII (Fw3a.39). Optical Society of America.
Abstract: We discuss the advantages and limitations of single-photon optical time-domain reflectometry with superconducting single-photon detectors. The higher two-point resolution can be achieved due to superior timing performance of SSPDs in comparison with InGaAs APDs.
|
Angeluts, A. A., Bezotosnyi, V. V., Cheshev, E. A., Goltsman, G. N., Finkel, M. I., Seliverstov, S. V., et al. (2014). Compact 1.64 THz source based on a dual-wavelength diode end-pumped Nd:YLF laser with a nearly semiconfocal cavity. Laser Phys. Lett., 11(1), 015004 (1 to 4).
Abstract: We describe a compact dual-wavelength (1.047 and 1.053 μm) diode end-pumped Q-switched Nd:YLE laser source which has a number of applications in demand. In order to achieve its dual-wavelength operation it is suggested for the first time to use essentially nonmonotonous dependences of the threshold pump powers at these wavelengths on the cavity length in the region of the cavity semiconfocal configuration under a radius of the pump beam smaller than the radius of the zero Gaussian mode. Here we demonstrate one of the most interesting applications for this laser: difference frequency generation in a GaSe crystal at a frequency of 1.64 THz. A superconducting hot-electron bolometer is used to detect the THz power generated and to measure its pulse characteristics.
|
Khasminskaya, S., Pyatkov, F., Słowik, K., Ferrari, S., Kahl, O., Kovalyuk, V., et al. (2016). Fully integrated quantum photonic circuit with an electrically driven light source. Nat. Photon., 10(11), 727–732.
Abstract: Photonic quantum technologies allow quantum phenomena to be exploited in applications such as quantum cryptography, quantum simulation and quantum computation. A key requirement for practical devices is the scalable integration of single-photon sources, detectors and linear optical elements on a common platform. Nanophotonic circuits enable the realization of complex linear optical systems, while non-classical light can be measured with waveguide-integrated detectors. However, reproducible single-photon sources with high brightness and compatibility with photonic devices remain elusive for fully integrated systems. Here, we report the observation of antibunching in the light emitted from an electrically driven carbon nanotube embedded within a photonic quantum circuit. Non-classical light generated on chip is recorded under cryogenic conditions with waveguide-integrated superconducting single-photon detectors, without requiring optical filtering. Because exclusively scalable fabrication and deposition methods are used, our results establish carbon nanotubes as promising nanoscale single-photon emitters for hybrid quantum photonic devices.
|
Korneeva, Y., Florya, I., Vdovichev, S., Moshkova, M., Simonov, N., Kaurova, N., et al. (2017). Comparison of hot-spot formation in NbN and MoN thin superconducting films after photon absorption. In IEEE Transactions on Applied Superconductivity (Vol. 27, 5).
Abstract: In superconducting single-photon detectors SSPD
the efficiency of local suppression of superconductivity and hotspot
formation is controlled by diffusivity and electron-phonon
interaction time. Here we selected a material, 3.6-nm-thick MoNx
film, which features diffusivity close to those of NbN traditionally
used for SSPD fabrication, but with electron-phonon interaction
time an order of magnitude larger. In MoNx detectors we study
the dependence of detection efficiency on bias current, photon
energy, and strip width and compare it with NbN SSPD. We
observe non-linear current-energy dependence in MoNx SSPD
and more pronounced plateaus in dependences of detection
efficiency on bias current which we attribute to longer electronphonon
interaction time.
|