Records |
Links |
|
Author |
Hoogeveen, R. W. M.; Yagoubov, P. A.; Maurellis, A.; Koshelets, V. P.; Shitov, S. V.; Mair, U.; Krocka, M.; Wagner, G.; Birk, M.; Huebers, H.-W.; Richter, H.; Semenov, A.; Gol’tsman, G. N.; Voronov, B. M.; Ellison, B.N.; Kerridge, B.J.; Matheson, D. N.; Alderman, B.; Harman, M.; Siddans, R.; Reburn, J. |
|
|
Title |
New cryogenic heterodyne techniques applied in TELIS: the balloonborne THz and submillimeter limb sounder for atmospheric research |
Type |
Conference Article |
|
Year |
2003 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
5152 |
Issue |
|
Pages |
347-355 |
|
|
Keywords |
TELIS, limb sounder, heterodyne detection, terahertz, sub millimeter, cryogenic, limb sounding, balloon borne, atmospheric research |
|
|
Abstract |
We present a design concept for a new state-of-the-art balloon borne atmospheric monitor that will allow enhanced limb sounding of the Earth’s atmosphere within the submillimeter and far-infrared wavelength spectral range: TELIS, TErahertz and submm LImb Sounder. The instrument is being developed by a consortium of major European institutes that includes the Space Research Organization of the Netherlands (SRON), the Rutherford Appleton Laboratory (RAL) will utilize state-of-the-art superconducting heterodyne technology and is designed to be a compact, lightweight instrument cpaable of providing broad spectral coverage, high spectral resolution and long flight duration ( 24 hours duration during a single flight campaign). The combination of high sensitivity and extensive flight duration will allow evaluation of the diurnal variation of key atmospheric constitutenets sucyh as OH, HO2, ClO, BrO togehter will onger lived constituents such as O3, HCL and N2O. Furthermore, TELIS will share a common balloon platform to that of the MIPAS-B Fourier Transform Spectrometer, developed by the Institute of Meteorology and Climate research of the over an extended spectral range. The combination of the TELIS and MIPAS instruments will provide atmospheric scientists with a very powerful observational tool. TELIS will serve as a testbed for new cryogenic heterodyne detection techniques, and as such it will act as a prelude to future spaceborne instruments planned by the European Space Agency (ESA). |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Strojnik, M. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Infrared Spaceborne Remote Sensing XI |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1508 |
|
Permanent link to this record |
|
|
|
|
Author |
Meledin, D.; Tong, C.-Y. E.; Blundell, R.; Goltsman, G. |
|
|
Title |
Measurement of intermediate frequency bandwidth of hot electron bolometer mixers at terahertz frequency range |
Type |
Journal Article |
|
Year |
2003 |
Publication |
IEEE Microw. Wireless Compon. Lett. |
Abbreviated Journal |
IEEE Microw. Wireless Compon. Lett. |
|
|
Volume |
13 |
Issue |
11 |
Pages |
493-495 |
|
|
Keywords |
waveguide NbN HEB mixers |
|
|
Abstract |
We have developed a new experimental setup for measuring the IF bandwidth of superconducting hot electron bolometer mixers. In our measurement system we use a chopped hot filament as a broadband signal source, and can perform a high-speed IF scan with no loss of accuracy when compared to coherent methods. Using this technique we have measured the 3 dB IF bandwidth of hot electron bolometer mixers, designed for THz frequency operation, and made from 3-4 nm thick NbN film deposited on an MgO buffer layer over crystalline quartz. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1531-1309 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1509 |
|
Permanent link to this record |
|
|
|
|
Author |
Cherednichenko, S.; Khosropanah, P.; Adam, A.; Merkel, H. F.; Kollberg, E. L.; Loudkov, D.; Gol'tsman, G. N.; Voronov, B. M.; Richter, H.; Huebers, H.-W. |
|
|
Title |
1.4- to 1.7-THz NbN hot-electron bolometer mixer for the Herschel space observatory |
Type |
Conference Article |
|
Year |
2003 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
4855 |
Issue |
|
Pages |
361-370 |
|
|
Keywords |
NbN HEB mixers |
|
|
Abstract |
NbN hot- electron bolometer mixers have reached the level of 10hv/k in terms of the input noise temperature with the noise bandwidth of 4-6 GHz from subMM band up to 2.5 THz. In this paper we discuss the major characteristics of this kind of receiver, i.e. the gain and the noise bandwidth, the noise temperature in a wide RF band, bias regimes and optimisation of RF coupling to the quasioptical mixer. We present the status of the development of the mixer for Band 6 Low for Herschel Telescope. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Phillips, T.G.; Zmuidzinas, J. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Millimeter and Submillimeter Detectors for Astronomy |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1521 |
|
Permanent link to this record |
|
|
|
|
Author |
Hübers, Heinz-Wilhelm; Semenov, A.; Richter, H.; Smirnov, K.; Gol'tsman, G.; Voronov, B. |
|
|
Title |
Phonon cooled far-infrared hot electron bolometer mixer |
Type |
Abstract |
|
Year |
2002 |
Publication |
NASA/ADS |
Abbreviated Journal |
NASA/ADS |
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
NbN HEB mixers |
|
|
Abstract |
Heterodyne receivers for applications in astronomy need quantum-limited sensitivity. At frequencies above 1.4 THz superconducting hot electron bolometers (HEB) can be used to achieve this goal. We present results of the development of a quasi-optical phonon-cooled NbN HEB mixer for GREAT, the German heterodyne receiver for SOFIA. Different mixers with logarithmic spiral and double slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern at several frequencies between 0.7 THz and 5.2 THz. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 16 dB. The response of the mixer was linear up to 400 K load temperature. This performance was verified by measuring an emission line of methanol at 2.5 THz. The results demonstrate that the NbN HEB is very well suited as a mixer for FIR heterodyne receivers. |
|
|
Address |
Monterey, CA |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Far-IR, Sub-mm & MM Detector Technology Workshop, 1-3 April 2002 |
|
|
Notes |
id.37 |
Approved |
no |
|
|
Call Number |
|
Serial |
1534 |
|
Permanent link to this record |
|
|
|
|
Author |
Semenov, A. D.; Hübers, H.-W.; Gol’tsman, G. N.; Smirnov, K. |
|
|
Title |
Superconducting quantum detector for astronomy and X-ray spectroscopy |
Type |
Conference Article |
|
Year |
2002 |
Publication |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
Abbreviated Journal |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
|
|
Volume |
|
Issue |
|
Pages |
201-210 |
|
|
Keywords |
NbN SSPD, SNSPD, SQD, superconducting quantum detectors, X-ray spectroscopy |
|
|
Abstract |
We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array. |
|
|
Address |
Naples, Italy |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
Boston, MA |
Editor |
Pekola, J.; Ruggiero, B.; Silvestrini, P. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-1-4615-0737-6 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
International Workshop on Superconducting Nano-Electronics Devices, May 28-June 1, 2001 |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
semenov2002superconducting |
Serial |
1525 |
|
Permanent link to this record |