Hajenius, M., Barends, R., Gao, J. R., Klapwijk, T. M., Baselmans, J. J. A., Baryshev, A., et al. (2005). Local resistivity and the current-voltage characteristics of hot electron bolometer mixers. IEEE Trans. Appl. Supercond., 15(2), 495–498.
Abstract: Hot-electron bolometer devices, used successfully in low noise heterodyne mixing at frequencies up to 2.5 THz, have been analyzed. A distributed temperature numerical model of the NbN bridge, based on a local electron and a phonon temperature, is used to model pumped IV curves and understand the physical conditions during the mixing process. We argue that the mixing is predominantly due to the strongly temperature dependent local resistivity of the NbN. Experimentally we identify the origins of different transition temperatures in a real HEB device, suggesting the importance of the intrinsic resistive transition of the superconducting bridge in the modeling.
|
Zhang, W., Miao, W., Zhong, J. Q., Shi, S. C., Hayton, D. J., Vercruyssen, N., et al. (2014). Temperature dependence of the receiver noise temperature and IF bandwidth of superconducting hot electron bolometer mixers. Supercond. Sci. Technol., 27(8), 085013 (1 to 5).
Abstract: In this paper we study the temperature dependence of the receiver noise temperature and IF noise bandwidth of superconducting hot electron bolometer (HEB) mixers. Three superconducting NbN HEB devices of different transition temperatures (Tc) are measured at 0.85 THz and 1.4 THz at different bath temperatures (Tbath) between 4 K and 9 K. Measurement results demonstrate that the receiver noise temperature of superconducting NbN HEB devices is nearly constant for Tbath/Tc, less than 0.8, which is consistent with the simulation based on a distributed hot-spot model. In addition, the IF noise bandwidth appears independent of Tbath/Tc, indicating the dominance of phonon cooling in the investigated HEB devices.
|
Zhang, W., Miao, W., Yao, Q. J., Lin, Z. H., Shi, S. C., Gao, J. R., et al. (2012). Spectral response and noise temperature of a 2.5 THz spiral antenna coupled NbN HEB mixer. Phys. Procedia, 36, 334–337.
Abstract: We report on a 2.5 THz spiral antenna coupled NbN hot electron bolometer (HEB) mixers, fabricated with in-situ process. The receiver noise temperature with lowest value of 1180 K is in good agreement with calculated quantum efficiency factor as a function of bias voltage. In addition, the measured spectral response of the spiral antenna coupled NbN HEB mixer shows broad frequency coverage of 0.8-3 THz, and corrected response for optical losses, FTS, and coupling efficiency between antenna and bolometer falls with frequency due to diffraction-limited beam of lens/antenna combination.
|
Pentin, I. V., Smirnov, A. V., Ryabchun, S. A., Ozhegov, R. V., Gol’tsman, G. N., Vaks, V. L., et al. (2012). Semiconducting superlattice as a solid-state terahertz local oscillator for NbN hot-electron bolometer mixers. Tech. Phys., 57(7), 971–974.
Abstract: We present the results of our studies of the semiconducting superlattice (SSL) frequency multiplier and its application as part of the solid state local oscillator (LO) in the terahertz heterodyne receiver based on a NbN hot-electron bolometer (HEB) mixer. We show that the SSL output power level increases as the ambient temperature is lowered to 4.2 K, the standard HEB operation temperature.
|
Ozhegov, R. V., Gorshkov, K. N., Okunev, O. V., & Gol’tsman, G. N. (2010). Superconducting hot-electron bolometer mixer as element of thermal imager matrix. Tech. Phys. Lett., 36(11), 1006–1008.
Abstract: The possibility of using a matrix of sensitive elements on a 12-mm-diameter hyperhemispherical lens in a thermal imager operating in the terahertz range has been studied. Dimensions of a lens region acceptable for arrangement of the matrix, in which the receiver noise temperature varies within 16% of the mean value, are determined to be 3.3% of the lens diameter. Deviations of the main lobe of the directivity pattern are evaluated, which amount to ±1.25° relative to the direction toward the optimum position of a mixer. The fluctuation sensitivity of the receiver measured in experiment is 0.5 K at a frequency of 300 GHz.
|