|
Gershenzon, E. M., Gol’tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation. IEEE Trans. Magn., 27(2), 1321–1324.
Abstract: Ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter waves to near infrared. With an increase in radiation frequency, the Josephson detection at the grain-boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. The electron-phonon relaxation time tau /sub eph/ is determined from direct measurements, quasi-stationary electron heating measurements, and the frequency dependence of the current at which maximum voltage shift is observed. The temperature dependence of tau /sub eph/ at T<or=40 K was found to be tau /sub eph/ approximately T/sup -1/. The results show that detectors with a response time of a few picoseconds at nitrogen temperature are attainable.
|
|
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Mirskij, G. I., & Semenov, A. D. (1991). Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution. Pribory i Tekhnika Eksperimenta, 34(2), 125–131.
Abstract: The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
|
|
|
Gershenzon, E. M., Gogidze, I. G., Goltsman, G. N., Semenov, A. D., & Sergeev, A. V. (1991). Picosecond response on optical-range emission in thin YBaCuO films. Pisma v Zhurnal Tekhnicheskoi Fiziki, 17(22), 6–10.
Abstract: Целью настоящей работы является целенаправленный поиск пико-секундного отклика на оптическое излучение выяснение оптимальных условий его наблюдения, а также сравнение характеристик неравновесных эффектов в оптическом и субмиллиметровом диапазонах.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1990). Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation. Solid State Communications, 76(4), 493–497.
Abstract: The ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter to near infrared. With the rise of radiation frequency the Josephson detection at the grain boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. Electron-phonon relaxation time τeph is determined by direct measurements and analyses quasistationary electron heating. Temperature dependence of τeph at T ≤ 40 K was found to be τeph ∼ T−1. The results show that detectors with the response time of few picoseconds at nitrogen temperature are attainable.
|
|
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1989). Interaction of electrons with thermal phonons in YBa2Cu3O7-δ films at low temperatures. JETP Lett., 50(5), 283–286.
Abstract: The time of electron-phonon interaction tau(eph) in YBaCuO films at low temperatures is studied. This is measured as the time of resistance relaxation in the resistive state of the superconducter, and is also determined from the increase in resistance under the action of radiation. Consistent results of these methods show that resistance relaxation in the resistive state is caused by cooling of the electron subsystem with respect to the phonon subsystem. The time tau(eph) is found to be inversely proportional to the temperature and comes to 80 ps when T = 1.6 K and 5 ps when T = 30 K. 6 refs.
|
|