|
Seliverstov, S. V., Rusova, A. A., Kaurova, N. S., Voronov, B. M., & Goltsman, G. N. (2016). Attojoule energy resolution of direct detector based on hot electron bolometer. In J. Phys.: Conf. Ser. (Vol. 741, 012165 (1 to 5)). IOP Publishing.
Abstract: We characterize superconducting antenna-coupled NbN hot-electron bolometer (HEB) for direct detection of THz radiation operating at a temperature of 9.0 K. At signal frequency of 2.5 THz, the measured value of the optical noise equivalent power is 2.0×10-13 W-Hz-0.5. The estimated value of the energy resolution is about 1.5 aJ. This value was confirmed in the experiment with pulsed 1.55-μm laser employed as a radiation source. The directly measured detector energy resolution is 2 aJ. The obtained risetime of pulses from the detector is 130 ps. This value was determined by the properties of the RF line. These characteristics make our detector a device-of-choice for a number of practical applications associated with detection of short THz pulses.
|
|
|
Angeluts, A. A., Bezotosnyi, V. V., Cheshev, E. A., Goltsman, G. N., Finkel, M. I., Seliverstov, S. V., et al. (2014). Compact 1.64 THz source based on a dual-wavelength diode end-pumped Nd:YLF laser with a nearly semiconfocal cavity. Laser Phys. Lett., 11(1), 015004 (1 to 4).
Abstract: We describe a compact dual-wavelength (1.047 and 1.053 μm) diode end-pumped Q-switched Nd:YLE laser source which has a number of applications in demand. In order to achieve its dual-wavelength operation it is suggested for the first time to use essentially nonmonotonous dependences of the threshold pump powers at these wavelengths on the cavity length in the region of the cavity semiconfocal configuration under a radius of the pump beam smaller than the radius of the zero Gaussian mode. Here we demonstrate one of the most interesting applications for this laser: difference frequency generation in a GaSe crystal at a frequency of 1.64 THz. A superconducting hot-electron bolometer is used to detect the THz power generated and to measure its pulse characteristics.
|
|
|
Neroev, V. V., Iomdina, E. N., Khandzhyan, A. T., Khodzhabekyan, N. V., Sengaeva, M. D., Ivanova, A. V., et al. (2021). Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy. Vestn. Oftalmol., 137(3), 68–75.
Abstract: Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.
Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.
Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).
Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).
Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
|
|
|
Seliverstov, S., Maslennikov, S., Ryabchun, S., Finkel, M., Klapwijk, T. M., Kaurova, N., et al. (2015). Fast and sensitive terahertz direct detector based on superconducting antenna-coupled hot electron bolometer. IEEE Trans. Appl. Supercond., 25(3), 2300304.
Abstract: We characterize superconducting antenna-coupled hot-electron bolometers for direct detection of terahertz radiation operating at a temperature of 9.0 K. The estimated value of responsivity obtained from lumped-element theory is strongly different from the measured one. A numerical calculation of the detector responsivity is developed, using the Euler method, applied to the system of heat balance equations written in recurrent form. This distributed element model takes into account the effect of nonuniform heating of the detector along its length and provides results that are in better agreement with the experiment. At a signal frequency of 2.5 THz, the measured value of the optical detector noise equivalent power is 2.0 × 10-13 W · Hz-0.5. The value of the bolometer time constant is 35 ps. The corresponding energy resolution is about 3 aJ. This detector has a sensitivity similar to that of the state-of-the-art sub-millimeter detectors operating at accessible cryogenic temperatures, but with a response time several orders of magnitude shorter.
|
|
|
Tuchak, A. N., Gol’tsman, G. N., Kitaeva, G. K., Penin, A. N., Seliverstov, S. V., Finkel, M. I., et al. (2012). Generation of nanosecond terahertz pulses by the optical rectification method. JETP Lett., 96(2), 94–97.
Abstract: The possibility of the generation of quasi-cw terahertz radiation by the optical rectification method for broad-band Fourier unlimited nanosecond laser pulses has been experimentally demonstrated. The broadband radiation of a LiF dye-center laser is used as a pump source of a nonlinear optical oscillator. The energy efficiency of terahertz optical frequency conversion in a periodically polarized lithium niobate crystal is 4 × 10−9 at a pump power density of 7 MW/cm2.
|
|
|
Tretyakov, I. V., Finkel, M. I., Ryabchun, S. A., Kardakova, A. I., Seliverstov, S. V., Petrenko, D. V., et al. (2014). Hot-electron bolometer mixers with in situ contacts. Radiophys. Quant. Electron., 56(8-9), 591–598.
Abstract: We report on the latest achievements in the development of superconducting hot-electron bolometer (HEB) mixers for terahertz superheterodyne receivers. We consider application ranges of such receivers and requirements for the basic characteristics of the mixers. Main features of the mixers, such as noise temperature, gain bandwidth, noise bandwidth, and required local-oscillator power, have been improved significantly over the past few years due to intense research work, both in terms of the element fabrication quality and in terms of understanding of the physics of the processes occurring in the HEB mixers. Contacts between the superconducting bridge and the planar antenna play a key role in the mixer operation. Improvement of the quality of the contacts leads simultaneously to a decrease in the noise temperature and an increase in the gain bandwidth of a mixer.
|
|
|
Shurakov, A., Seliverstov, S., Kaurova, N., Finkel, M., Voronov, B., & Goltsman, G. (2012). Input bandwidth of hot electron bolometer with spiral antenna. IEEE Trans. THz Sci. Technol., 2(4), 400–405.
Abstract: We report the results of our study of the input bandwidth of hot electron bolometers (HEB) embedded into the planar log-spiral antenna. The sensitive element is made of the ultrathin superconducting NbN film patterned as a bridge at the feed of the antenna. The contacts between the antenna and a sensitive element are made from in situ deposited gold (i.e., deposited over NbN film without breaking vacuum), which gives high quality contacts and makes the response of the HEB at higher frequencies less affected by the RF loss. An accurate experimental spectroscopic procedure is demonstrated that leads to the confirmation of the wide ( 8 THz) bandwidth in this antenna coupled device.
|
|
|
Gayduchenko, I. A., Fedorov, G. E., Moskotin, M. V., Yagodkin, D. I., Seliverstov, S. V., Goltsman, G. N., et al. (2018). Manifestation of plasmonic response in the detection of sub-terahertz radiation by graphene-based devices. Nanotechnol., 29(24), 245204 (1 to 8).
Abstract: We report on the sub-terahertz (THz) (129-450 GHz) photoresponse of devices based on single layer graphene and graphene nanoribbons with asymmetric source and drain (vanadium and gold) contacts. Vanadium forms a barrier at the graphene interface, while gold forms an Ohmic contact. We find that at low temperatures (77 K) the detector responsivity rises with the increasing frequency of the incident sub-THz radiation. We interpret this result as a manifestation of a plasmonic effect in the devices with the relatively long plasmonic wavelengths. Graphene nanoribbon devices display a similar pattern, albeit with a lower responsivity.
|
|
|
Iomdina, E. N., Goltsman, G. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., & Rusova, A. A. (2016). Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range. J. Biomed. Opt., 21(9), 97002 (1 to 5).
Abstract: An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Keywords: BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology
|
|
|
Seliverstov, S. V., Anfertyev, V. A., Tretyakov, I. V., Ozheredov, I. A., Solyankin, P. M., Revin, L. S., et al. (2017). Terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. Radiophys. Quant. Electron., 60(7), 518–524.
Abstract: We study characteristics of the laboratory prototype of a terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. The results obtained demonstrate the possibility to use this receiver as a basis for creation of a high-sensitivity terahertz spectrometer, which can be used in many basic and practical applications. A significant advantage of this receiver will be the possibility of placing the mixer and heterodyne in the same cryostat, which will reduce the device dimensions considerably. The obtained experimental results are analyzed, and methods of optimizing the parameters of the receiver are proposed.
|
|