|
Cherednichenko, S., Drakinskiy, V., Baubert, J., Lecomte, B., Dauplay, F., Krieg, J. M., et al. (2006). 2.5 THz multipixel heterodyne receiver based on NbN HEB mixers. In Proc. SPIE (Vol. 6275, 62750I (1 to 11)).
Abstract: A 16 pixel heterodyne receiver for 2.5 THz has been developed based on NbN superconducting hot-electron bolometer (HEB) mixers. The receiver uses a quasioptical RF coupling approach where HEB mixers are integrated into double dipole antennas on 1.5 µm thick Si3N4/SiO2 membranes. Spherical mirrors (one per pixel) and backshort distance from the antenna have been used to design the output mixer beam profile. The camera design allows all 16 pixel IF readout in parallel. The gain bandwidth of the HEB mixers on Si3N4/SiO2 membranes was found to be 0.7÷0.9 GHz, which is much smaller than for similar devices on silicon. Application of buffer layers and use of alternative types of membranes (e.g. silicon-on-insulator) is under investigation.
|
|
|
Yagoubov, P., Hoogeveen, R., Torgashin, M., Khudchenko, A., Koshelets, V., Suttiwong, N., et al. (2006). 550-650 GHz spectrometer development for TELIS. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 338–341).
|
|
|
Shitov, S. V., & Vystavkin, A. N. (2006). A design analysis of imaging radiometer with antenna-coupled transition-edge sensors. Nuclear Instruments and Methods in Physics Research A, 559, 503–505.
|
|
|
Dauler, E. A., Kerman, A. J., Robinson, B. S., Yang, J. K. W., Voronov, B. M., Gol’tsman, G. N., et al. (2006). Achieving high counting rates in superconducting nanowire single-photon detectors. In CLEO/QELS (JTuD3 (1 to 2)). Optical Society of America.
Abstract: Kinetic inductance is determined to be the primary limitation to the counting rate of superconducting nanowire single-photon counters. Approaches for overcoming this limitation will be discussed.
|
|
|
David Olaya, Jian Wei, Sergei Pereverzev, Karasik, B. S., Kawamura, Jhan H., McGrath, W. R., et al. (2006). An ultrasensitive hot-electron bolometer for low-background SMM applications. In Proc. SPIE (Vol. 6275, 627506).
|
|
|
Koshelets, V. P., & Khudchenko, A. V. (2006). Analysis of spectral characteristics of a superconducting integrated receiver. J. Communications Technol. Electron., 51(5), 596–603.
|
|
|
Koshelets, V. P., & Khudchenko, A. V. (2006). Analysis of spectral characteristics of a superconducting integrated receiver. J. Communications Technol. Electron., 51(5), 596–603.
|
|
|
(2006). Atacama Pathfinder Experiment APEX.
|
|
|
Kenyon, M., Day, P. K., Bradford, C. M., Bock, J. J., & Leduc, H. G. (2006). Background-limited membrane-isolated TES bolometers for far-IR/submillimeter direct-detection spectroscopy. Nucl. Instr. & Meth. Phys. Res. A, 559, 456–458.
|
|
|
Gao, J. R., Hajenius, M., Tichelaar, F. D., Voronov, B., Grishina, E., Klapwijk, T. M., et al. (2006). Can NbN films on 3C-SiC/Si change the IF bandwidth of hot electron bolometer mixers? In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 187–189).
Abstract: We realized ultra thin NbN films sputtered grown on a 3C-SiC/Si substrate. The film with a thickness of 3.5-4.5 nm shows a 1', of 11.8 K, which is the highest I`, observed among ultra thin NbN films on different substrates. The high-resolution transmission electron microscopy (HRTEM) studies show that the film has a monocrystalline structure, confirming the epitaxial growth on the 3C-SiC. Based on a two-temperature model and input parameters from standard NbN films on Si, simulations predict that the new film can increase the IF bandwidth of a HEB mixer by about a factor of 2 in comparison to the standard films. In addition, we find standard NbN films on Si with a T c of 9.4 K have a thickness of around 5.5 nm, being thicker than expected (3.5 nm).
|
|
|
Brown, E. R., Lee, A. W. M., Navi, B. S., & Bjarnason, J. E. (2006). Characterization of a planar self-complementary square-spiral antenna in the THz region. Microwave Opt Technol Lett, 48(3), 524–529.
Abstract: This paper describes a compact, self-complementary square-spiral antenna on a GaAs substrate with a broadside high-directivity (~9 dB) frequency-independent pattern when coupled through a silicon hyperhemisphere. The driving-point resistance undulates between ~00 and 300Ω from 200 GHz to 1 THz—much higher than the 72Ω value from Booker's modified formula, but quite beneficial for coupling to high-impedance broadband devices
|
|
|
Jiang, L., Miao, W., Zhang, W., Li, N., Lin, Z. H., Yao, Q. J., et al. (2006). Characterization of a quasi-optical NbN superconducting HEB mixer. IEEE Trans. Microwave Theory Techn., 54(7), 2944–2948.
Abstract: In this paper, the performance of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer, cryogenically cooled by a close-cycled 4-K refrigerator, is thoroughly investigated at 300, 500, and 850 GHz. The lowest receiver noise temperatures measured at the respective three frequencies are 1400, 900, and 1350 K, which can go down to 659, 413, and 529 K, respectively, after correcting the loss and associated noise contribution of the quasi-optical system before the measured superconducting HEB mixer. The stability of the quasi-optical superconducting HEB mixer is also investigated here. The Allan variance time measured with a local oscillator pumping at 500 GHz and an IF bandwidth of 110 MHz is 1.5 s at the dc-bias voltage exhibiting the lowest noise temperature and increases to 2.5 s at a dc bias twice that voltage.
|
|
|
Jiang, L., Miao, W., Zhang, W., Li, N., Lin, Z. H., Yao, Q. J., et al. (2006). Characterization of quasi-optical NbN phonon-cooled superconducting HEB mixers. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 55–58).
Abstract: In this paper, we thoroughly investigate the performance of quasi-optical NbN phonon-cooled superconducting hot-electron bolometer (HEB) mixers, cryogenically cooled by a close-cycled 4-K refrigerator at 500 GI-1z and 850 GHz. The uncorrected lowest receiver noise Abstract---In temperatures measured are 800 K at 500 CHz without anti-reflection coating, and 1000 K @ 850 GHz with a 50 11M thick Mylar anti-reflection coating. The dependence of receiver noise temperature on the critical current and bath temperature of HEB mixer is also investigated here. Lifetime of quasi-optical superconducting NbN HEB mixers of different volumes, room temperature resistances, and critical temperatures are thoroughly studied. Increased room temperature resistance with time over the initial resistance changes between 1 and 1.2, and the reduced critical current with time over the initial value fluctuates slightly around 0.7 for most HEB mixers even of different volumes, room temperature resistances, and critical temperatures. The critical current degrades sharply vvhile room temperature resistance varies over 1.25.
|
|
|
Baryshev A. M., Candotti, M., & Trappe, N. A. (2006). Cross-polarization characteristics of GORE-TEX slabs at band 9 frequencies.
|
|
|
Karpov, A., Miller, D., Rice, F., Stern, J. A., Bumble, B., LeDuc, H. G., et al. (2006). Development of 1.25 THz SIS mixer for Herschel Space Observatory. In J. Zmuidzinas, & W. S. Holland (Eds.), Proc. SPIE (Vol. 6275, 62751).
|
|