Shcherbatenko, M., Tretyakov, I., Lobanov, Y., Maslennikov, S. N., Kaurova, N., Finkel, M., et al. (2016). Nonequilibrium interpretation of DC properties of NbN superconducting hot electron bolometers. Appl. Phys. Lett., 109(13), 132602.
Abstract: We present a physically consistent interpretation of the dc electrical properties of niobiumnitride (NbN)-based superconducting hot-electron bolometer mixers, using concepts of nonequilibrium superconductivity. Through this, we clarify what physical information can be extracted from the resistive transition and the dc current-voltage characteristics, measured at suitably chosen temperatures, and relevant for device characterization and optimization. We point out that the intrinsic spatial variation of the electronic properties of disordered superconductors, such as NbN, leads to a variation from device to device.
|
|
|
Matyushkin, Y., Kaurova, N., Voronov, B., Goltsman, G., & Fedorov, G. (2020). On chip carbon nanotube tunneling spectroscopy. Fullerenes, Nanotubes and Carbon Nanostructures, 28(1), 50–53.
Abstract: We report an experimental study of the band structure of individual carbon nanotubes (SCNTs) based on investigation of the tunneling density of states, i.e. tunneling spectroscopy. A common approach to this task is to use a scanning tunneling microscope (STM). However, this approach has a number of drawbacks, to overcome which, we propose another method – tunneling spectroscopy of SCNTs on a chip using a tunneling contact. This method is simpler, cheaper and technologically advanced than the STM. Fabrication of a tunnel contact can be easily integrated into any technological route, therefore, a tunnel contact can be used, for example, as an additional tool in characterizing any devices based on individual CNTs. In this paper we demonstrate a simple technological procedure that results in fabrication of good-quality tunneling contacts to carbon nanotubes.
|
|
|
Komrakova, S., Javadzade, J., Vorobyov, V., Bolshedvorskii, S., Soshenko, V., Akimov, A., et al. (2018). On-chip controlled placement of nanodiamonds with a nitrogen-vacancy color centers (NV). In J. Phys.: Conf. Ser. (Vol. 1124, 051046 (1 to 4)).
Abstract: Here we studied the fabrication technique of a kilopixel array of nanodiamonds with a nitrogen-vacancy color centers (NV) on top of the chip and measured the second-order correlation function deep, clearly demonstrated the presence of single-photon sources. The controlled position of nanodiamonds, determined from the measurement of second-order correlation fiction, was realize, as well as the yield of optimized technique equals 12.5% is shown.
|
|
|
Kovalyuk, V., Kahl, O., Ferrari, S., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2018). On-chip single-photon spectrometer for visible and infrared wavelength range. In J. Phys.: Conf. Ser. (Vol. 1124, 051045).
Abstract: Here we show our latest progress in the field of a single-photon spectrometer for the visible and infrared wavelengths ranges implementation. We consider three different on-chip approaches: a coherent spectrometer with a low power of the heterodyne, a coherent spectrometer with a high power of the heterodyne, and an eight-channel single-photon spectrometer for direct detection. Along with high efficiency, spectrometers show high detection efficiency and temporal resolution through the use of waveguide integrated superconducting nanowire single-photon detectors.
|
|
|
Korneeva, Y. P., Vodolazov, D. Y., Semenov, A. V., Florya, I. N., Simonov, N., Baeva, E., et al. (2018). Optical single photon detection in micron-scaled NbN bridges. arXiv:1802.02881v1 [cond-mat.supr-con]. Retrieved June 30, 2024, from https://arxiv.org/abs/1802.02881v1
Abstract: We demonstrate experimentally that single photon detection can be achieved in micron-wide NbN bridges, with widths ranging from 0.53 μm to 5.15 μm and for photon-wavelengths from 408 nm to 1550 nm. The microbridges are biased with a dc current close to the experimental critical current, which is estimated to be about 50 % of the theoretically expected depairing current. These results offer an alternative to the standard superconducting single-photon detectors (SSPDs), based on nanometer scale nanowires implemented in a long meandering structure. The results are consistent with improved theoretical modelling based on the theory of non-equilibrium superconductivity including the vortex-assisted mechanism of initial dissipation.
|
|
|
Korneeva, Y. P., Vodolazov, D. Y., Semenov, A. V., Florya, I. N., Simonov, N., Baeva, E., et al. (2018). Optical single-photon detection in micrometer-scale NbN bridges. Phys. Rev. Applied, 9(6), 064037 (1 to 13).
Abstract: We demonstrate experimentally that single-photon detection can be achieved in micrometer-wide NbN bridges, with widths ranging from 0.53 to 5.15 μm and for photon wavelengths of 408 to 1550 nm. The microbridges are biased with a dc current close to the experimental critical current, which is estimated to be about 50% of the theoretically expected depairing current. These results offer an alternative to the standard superconducting single-photon detectors, based on nanometer-scale nanowires implemented in a long meandering structure. The results are consistent with improved theoretical modeling based on the theory of nonequilibrium superconductivity, including the vortex-assisted mechanism of initial dissipation.
|
|
|
Shcherbatenko, M., Elezov, M., Sych, D., & Goltsman, G. N. (2020). Optimal fiber optic scheme for sub-SQL quantum receiver realization. In J. Phys.: Conf. Ser. (Vol. 1695, 012140).
Abstract: Practical implementation of high-precision quantum measurements is an important problem in modern science. One of the main parts of the quantum receiver is the optical scheme. We developed and tested several optical circuits based on different types of interferometers, namely Sagnac-based scheme, Mach-Zehnder-based scheme, and Michelson-based scheme. All these schemes are assembled with optical fibers and fiber-optic components, since the fiber-optic implementation is closest to application in practical devices. Schemes were evaluated according to two main criteria: extinction and interference stability. On the basis of the obtained data, it can be concluded that the most suitable is the scheme based on the Mach-Zehnder interferometer. In continuous mode, we were able to obtain an interference extinction about 30 dB with acceptable temporal stability.
|
|
|
Zubkova, E., An, P., Kovalyuk, V., Korneev, A., Ferrari, S., Pernice, W., et al. (2018). Optimization of contra-directional coupler based on silicon nitride Bragg rib waveguide. In J. Phys.: Conf. Ser. (Vol. 1124, 051048).
Abstract: We report on the development and fabrication of a contra-directional coupler based on the Bragg waveguide on Si3N4 platform. Transmitted and reflected by the contra-directional coupler spectra were measured. The reflected spectra exactly matches the one notched by the main channel of the coupler. Losses are about 3dB, coupling to the directing branch of the coupler is practically lossless. FWHM of the transmitted (reflected) spectra is 3.46 nm.
|
|
|
Prokhodtsov, A., An, P., Kovalyuk, V., Zubkova, E., Golikov, A., Korneev, A., et al. (2018). Optimization of on-chip photonic delay lines for telecom wavelengths. In J. Phys.: Conf. Ser. (Vol. 1124, 051052).
Abstract: In this work, we experimentally studied optical delay lines on silicon nitride platform for telecomm wavelength (1550 nm). We modeled the group delay time and fabricated spiral optical delay lines with different waveguide widths and radii as well as measured their transmission. For the half etched rib waveguides we achieved the losses in the range of 3 dB/cm.
|
|
|
Trifonov, A., Tong, C. - Y. E., Lobanov, Y., Kaurova, N., Blundell, R., & Goltsman, G. (2017). Photon absorption near the gap frequency in a hot electron bolometer. IEEE Trans. Appl. Supercond., 27(4), 1–4.
Abstract: The superconducting energy gap is a fundamental characteristic of a superconducting film, which, together with the applied pump power and the biasing setup, defines the instantaneous resistive state of the Hot Electron Bolometer (HEB) mixer at any given bias point on the I-V curve. In this paper we report on a series of experiments, in which we subjected the HEB to radiation over a wide frequency range along with parallel microwave injection. We have observed three distinct regimes of operation of the HEB, depending on whether the radiation is above the gap frequency, far below it or close to it. These regimes are driven by the different patterns of photon absorption. The experiments have allowed us to derive the approximate gap frequency of the device under test as about 585 GHz. Microwave injection was used to probe the HEB impedance. Spontaneous switching between the superconducting (low resistive) state and a quasi-normal (high resistive) state was observed. The switching pattern depends on the particular regime of HEB operation and can assume a random pattern at pump frequencies below the gap to a regular relaxation oscillation running at a few MHz when pumped above the gap.
|
|