Shurakov, A., Prikhodko, A., Mikhailov, D., Belikov, I., Kaurova, N., Voronov, B., et al. (2020). Efficiency of a microwave reflectometry for readout of a THz multipixel Schottky diode direct detector. In J. Phys.: Conf. Ser. (Vol. 1695, 012156).
Abstract: In this paper we report on the results of investigation of efficiency of a microwave reflectometry for readout of a terahertz multipixel Schottky diode direct detector. Decent capabilities of the microwave reflectometry readout were earlier justified by us for a hot electron bolometric direct detector. In case of a planar Schottky diode, we observed increase of an optical noise equivalent power by a factor of 2 compared to that measured within a conventional readout scheme. For implementation of a multipixel camera, a microwave reflectometer is to be used to readout each row of the camera, and the row switching is to be maintained by a CMOS analog multiplexer. The diodes within a row have to be equipped with filters to distribute the probing microwave signal properly. The simultaneous use of analog multiplexing and microwave reflectometry enables to reduce the camera response time by a factor of its number of columns.
|
Gol’tsman, G. N., Semenov, A. D., Sergeev, A. V., Aksaev, E. E., Gogidze, I. G., & Gershenzon, E. M. (1993). Electron-phonon interaction in thin YBaCuO films and fast detectors. In M. Meissner, & R. O. Pohl (Eds.), Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences (Vol. 112, pp. 184–185).
Abstract: The thin. YBaCuO film response to laser and submillimeter radiation demonstrates the picosecond nonequilibrium peak on the nanosecond bolometric background. Experimental data give an evidence for the spectral dependence of picosecond photoresponse probably due to a poor efficiency of electron multiplication processes. Presented results prove an availability of fast YBaCuO thin film detector.
|
Vystavkin, A. N. (1999). Estimation of noise equivalent power and design analysis of an andreev reflection hot-electron microbolometer for submillimeter radioastronomy. Rus. J. Radio Electron., (10).
Abstract: Results of theoretical estimations and measurements of characteristics of an Andreev reflection hot-electron microbolometer for submillimeter radioastronomy made by different researchers are reviewed and analysed. Peculiarities and characteristics of the microbolometers using two types of microthermometer for measurement of the electron temperature increment under influence of the radiation: the SIN-junction and the transition-edge sensor (TES) with electrothermal feedback – are compared. Advantages of the microbolometer with the second type of the microthermometer when the TES is used simultaneously as the absorber of radiation are shown. Methods of achievement of the best noise equivalent power of the microbolometer in such version as well as methods of the matching the microbolometer with the incident radiation flow using planar antennas and with the channel of output signal measurement using a SQUID-picoammeter are considered.
|
Semenov, A. D., Goghidze, I. G., Gol’tsman, G. N., Sergeev, A. V., & Gershenzon, E. M. (1993). Evidence for the spectral dependence of nonequilibrium picosecond photoresponse of YBaCuO thin films. Appl. Phys. Lett., 63(5), 681–683.
Abstract: The transient voltage photoresponse of current biased YBaCuO thin films to 20 ps laser pulses of 0.63 and 1.54 μm wavelengths is measured for temperatures around the superconducting transition region. The fast picosecond decay of the response is followed by a slow nanosecond relaxation which is associated with the bolometric effect. The magnitude of the fast component of the response varies in proportion to the square root of wavelength that plausibly reflects multiplication processes of photoexcited electrons via electron–electron scattering and interaction with high energy phonons.
|
Polyakova, M. I., Florya, I. N., Semenov, A. V., Korneev, A. A., & Goltsman, G. N. (2019). Extracting hot-spot correlation length from SNSPD tomography data. In J. Phys.: Conf. Ser. (Vol. 1410, 012166 (1 to 4)).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|