Records |
Author |
Zolotov, P.; Divochiy, A.; Vakhtomin, Y.; Moshkova, M.; Morozov, P.; Seleznev, V.; Smirnov, K. |
Title ![sorted by Title field, ascending order (up)](img/sort_asc.gif) |
Photon-number-resolving SSPDs with system detection efficiency over 50% at telecom range |
Type |
Conference Article |
Year |
2018 |
Publication |
Proc. AIP Conf. |
Abbreviated Journal |
|
Volume |
1936 |
Issue |
1 |
Pages |
020019 |
Keywords |
NbN PNR SSPD, SNSPD |
Abstract |
We used technology of making high-efficiency superconducting single-photon detectors as a basis for improvement of photon-number-resolving devices. By adding optical cavity and using an improved NbN superconducting film, we enhanced previously reported system detection efficiency at telecom range for such detectors. Our results show that implementation of optical cavity helps to develop four-section device with quantum efficiency over 50% at 1.55 µm. Performed experimental studies of detecting multi-photon optical pulses showed irregularities over defining multi-photon through single-photon quantum efficiency. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
doi:10.1063/1.5025457 |
Serial |
1231 |
Permanent link to this record |
|
|
|
Author |
Fedorov, G.; Kardakova, A.; Gayduchenko, I.; Voronov, B. M.; Finkel, M.; Klapwijk, T. M.; Goltsman, G. |
Title ![sorted by Title field, ascending order (up)](img/sort_asc.gif) |
Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-THz radiation |
Type |
Abstract |
Year |
2014 |
Publication |
Proc. 25th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 25th Int. Symp. Space Terahertz Technol. |
Volume |
|
Issue |
|
Pages |
71 |
Keywords |
carbon nanotubes, CNT |
Abstract |
This work reports on the voltage response of asymmetric carbon nanotube devices to sub-THz radiation at the frequency of 140 GHz. The devices contain CNT’s, which are over their length partially suspended and partially Van der Waals bonded to a SiO 2 substrate, causing a difference in thermal contact. Different heat sinking of CNTs by source and drain gives rise to temperature gradient and consequent thermoelectric power (TEP) as such a device is exposed to the sub-THz radiation. Sign of the DC signal, its power and gate voltage dependence observed at room temperature are consistent with this scenario. At liquid helium temperature the observed response is more complex. DC voltage signal of an opposite sign is observed in a narrow range of gate voltages at low temperatures and under low radiation power. We argue that this may indicate a true photovoltaic response from small gap (less than 10meV) CNT’s, an effect never reported before. While it is not clear if the observed effects can be used to develop efficient THz detectors we note that the responsivity of our devices exceeds that of CNT based devices in microwave or THz range reported before at room temperature. Besides at 4.2 K notable increase of the sample conductance (at least four-fold) is observed. Our recent results with asymmetric carbon nanotube devices response to THz radiation (2.5 THz) will also be presented. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1361 |
Permanent link to this record |
|
|
|
Author |
Karasik, B.S.; Lindgren, M.; Zorin, M.A.; Danerud, M.; Winkler, D.; Trifonov, V.V.; Gol’tsman, G.N.; Gershenzon, E.M. |
Title ![sorted by Title field, ascending order (up)](img/sort_asc.gif) |
Picosecond detection and broadband mixing of near-infrared radiation by YBaCuO films |
Type |
Conference Article |
Year |
1994 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
2159 |
Issue |
|
Pages |
68-76 |
Keywords |
YBCO HTS HEB mixer |
Abstract |
Nonequilibrium picosecond and bolometric responses of YBCO films 500 angstroms thick patterned into 20 X 20 micrometers 2 size structure to 17 ps laser pulses and modulated radiation of GaAs and CO2 lasers have been studied. The modulation frequencies up to 10 GHz for GaAs laser and up to 1 GHz for CO2 were attained. The use of small radiation power (1 – 10 mW/cm2 for cw radiation and 10 – 100 nJ/cm2 for pulse radiation) in combination with high sensitive read-out system made possible to avoid any non-linear transient processes caused by an overheating of sample above a critical temperature or S-N switching enhanced by an intense radiation. Responses due to the change of kinetic inductance were believed to be negligible. The only signals observed were caused by a small change of the film resistance either in the resistive state created by a bias current or in the normal state. The data obtained by means of pulse and modulation techniques are in agreement. The responsivity about 1 V/W was measured at 1 GHz modulation frequency both for 0.85 micrometers and 10.6 micrometers wavelengths. The sensitivity of high-Tc fast wideband infrared detector is discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Spie |
Place of Publication |
|
Editor |
Nahum, M.; Villegier, J.-C. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
High-Temperature Superconducting Detectors: Bolometric and Nonbolometric |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1640 |
Permanent link to this record |
|
|
|
Author |
Danerud, M.; Winkler, D.; Zorin, M.; Trifonov, V.; Karasik, B.; Gershenzon, E. M.; Gol'tsman, G. N.; Lindgren, M. |
Title ![sorted by Title field, ascending order (up)](img/sort_asc.gif) |
Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films |
Type |
Conference Article |
Year |
1993 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
2104 |
Issue |
|
Pages |
183-184 |
Keywords |
YBCO HTS HEB detectors |
Abstract |
Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Spie |
Place of Publication |
|
Editor |
Birch, J.R.; Parker, T.J. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
18th International Conference on Infrared and Millimeter Waves |
Notes |
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=25034664 |
Approved |
no |
Call Number |
10.1117/12.2298489 |
Serial |
1653 |
Permanent link to this record |
|
|
|
Author |
Gershenzon, E. M.; Gol’tsman, G. N.; Sergeev, A.; Semenov, A. D. |
Title ![sorted by Title field, ascending order (up)](img/sort_asc.gif) |
Picosecond response of YBaCuO films to electromagnetic radiation |
Type |
Conference Article |
Year |
1990 |
Publication |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
Abbreviated Journal |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
Volume |
|
Issue |
|
Pages |
457-462 |
Keywords |
YBCO HTS detectors |
Abstract |
Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
Gorzkowski, W.; Gutowski, M.; Reich, A.; Szymczak, H. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
European Conference , Ustroń, Poland , 30 Sept – 4 Oct 1989 |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1695 |
Permanent link to this record |