toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Zhou, Y.D.; Becker, C. R.; Ashokan, R.; Selamet, Y.; Chang, Y.; Boreiko, R. T.; Betz, A. L.; Sivananthan, S. openurl 
  Title (down) Progress in far-infrared detection technology Type Conference Article
  Year 2002 Publication Proc. SPIE Abbreviated Journal  
  Volume 4795 Issue Pages 121-128  
  Keywords HgCdTe/CdTe, detector  
  Abstract II-VI intrinsic very long wavelength infrared (VLWIR, λc~20 to 50 μm) materials, HgCdTe alloys as well as HgCdTe/CdTe superlattices, were grown by molecular beam epitaxy (MBE). The layers were characterized by means of X-ray diffraction, conventional Fourier transform infrared spectroscopy, Hall effect measurements and transmittance electron microscopy (TEM). Photoconductor devices were processed and their spectral response was also measured to demonstrate their applicability in the VLWIR region.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Longshore, R. E.; Sivananthan, S. Series Title Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 471  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gol'tsman, G. N.; Gogidze, I. G.; Semenov, A. D.; Sergeev, A. V. url  doi
openurl 
  Title (down) Processes of electron-phonon interaction in thin YBaCuO films Type Journal Article
  Year 1991 Publication Phys. C: Supercond. Abbreviated Journal Phys. C: Supercond.  
  Volume 185-189 Issue Pages 1371-1372  
  Keywords YBCO HTS detectors  
  Abstract The ultrafast voltage response of YBaCuO films to laser radiation is studied and compared with previously investigated quasiparicles response to radiation of submillimeter wavelength range. Voltage shift under the visible light radiation has two components. Picosecond response realized as suppression superconductivity by nonequilibrium excess quasiparticles, response time is determined by quasiparticles recombination rate. Nanosecond response is probably due to bolometric effect.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0921-4534 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1676  
Permanent link to this record
 

 
Author Nebosis, R. S.; Steinke, R.; Lang, P. T.; Schatz, W.; Heusinger, M. A.; Renk, K. F.; Gol’tsman, G. N.; Karasik, B. S.; Semenov, A. D.; Gershenzon, E. M. url  doi
openurl 
  Title (down) Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation Type Journal Article
  Year 1992 Publication J. Appl. Phys. Abbreviated Journal J. Appl. Phys.  
  Volume 72 Issue 11 Pages 5496-5499  
  Keywords YBCO HTS detectors  
  Abstract We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0021-8979 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1668  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gogidze, I. G.; Goltsman, G. N.; Semenov, A. D.; Sergeev, A. V. url  openurl
  Title (down) Picosecond response on optical-range emission in thin YBaCuO films Type Journal Article
  Year 1991 Publication Pisma v Zhurnal Tekhnicheskoi Fiziki Abbreviated Journal Pisma v Zhurnal Tekhnicheskoi Fiziki  
  Volume 17 Issue 22 Pages 6-10  
  Keywords YBCO HTS detectors  
  Abstract Целью настоящей работы является целенаправленный поиск пико-секундного отклика на оптическое излучение выяснение оптималь­ных условий его наблюдения, а также сравнение характеристик не­равновесных эффектов в оптическом и субмиллиметровом диапазонах.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Russian Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1684  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gol’tsman, G. N.; Sergeev, A.; Semenov, A. D. doi  openurl
  Title (down) Picosecond response of YBaCuO films to electromagnetic radiation Type Conference Article
  Year 1990 Publication Proc. European Conf. High-Tc Thin Films and Single Crystals Abbreviated Journal Proc. European Conf. High-Tc Thin Films and Single Crystals  
  Volume Issue Pages 457-462  
  Keywords YBCO HTS detectors  
  Abstract Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor Gorzkowski, W.; Gutowski, M.; Reich, A.; Szymczak, H.  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference European Conference , Ustroń, Poland , 30 Sept – 4 Oct 1989  
  Notes Approved no  
  Call Number Serial 1695  
Permanent link to this record
 

 
Author Voronov, B. M.; Gershenzon, E. M.; Gol'tsman, G. N.; Gogidze, I. G.; Gusev, Yu. P.; Zorin, M. A.; Sejdman, L. A.; Semenov, A. D. url  openurl
  Title (down) Picosecond range detector base on superconducting niobium nitride film sensitive to radiation in spectral range from millimeter waves up to visible light Type Journal Article
  Year 1992 Publication Sverkhprovodimost': Fizika, Khimiya, Tekhnika Abbreviated Journal Sverkhprovodimost': Fizika, Khimiya, Tekhnika  
  Volume 5 Issue 5 Pages 955-960  
  Keywords NbN HEB detectors  
  Abstract Fast-operating picosecond detector of electromagnetical radiation is developed on the basis of fine superconducting film of niobium nitride with high sensitivity within spectral range from millimetric waves up to visible light. Detector sensitive element represents structure covering narrow parallel strips with micron sizes included in the rupture of microstrip line. Detecting ability of the detector and time constant measured using amplitude-simulated radiation of reverse wave tubes and pulse radiation of picosecond gas and solid-body lasers, constitute D*≅1010 W-1·cm·Hz-1/2 and τ≤5 ps respectively, at 10 K temperature. The expected value of time constant of the detector at 10 K obtained via extrapolation of directly measured dependence that is, τ ∝ τ-1, constitutes 20 ps. Experimental data demonstrate that detection mechanism is linked with electron heating effect.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Russian Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0131-5366 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1670  
Permanent link to this record
 

 
Author Il'in, K. S.; Lindgren, M.; Currie, M. A.; Semenov, D.; Gol'tsman, G. N.; Sobolewski, Roman; Cherednichenko, S. I.; Gershenzon, E. M. url  doi
openurl 
  Title (down) Picosecond hot-electron energy relaxation in NbN superconducting photodetectors Type Journal Article
  Year 2000 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.  
  Volume 76 Issue 19 Pages 2752-2754  
  Keywords NbN HEB detectors, two-temperature model, IF bandwidth  
  Abstract We report time-resolved characterization of superconducting NbN hot-electron photodetectors using an electro-optic sampling method. Our samples were patterned into micron-size microbridges from 3.5-nm-thick NbN films deposited on sapphire substrates. The devices were illuminated with 100 fs optical pulses, and the photoresponse was measured in the ambient temperature range between 2.15 and 10.6 K (superconducting temperature transition TC). The experimental data agreed very well with the nonequilibrium hot-electron, two-temperature model. The quasiparticle thermalization time was ambient temperature independent and was measured to be 6.5 ps. The inelastic electron–phonon scattering time Ï„e–ph tended to decrease with the temperature increase, although its change remained within the experimental error, while the phonon escape time Ï„es decreased almost by a factor of two when the sample was put in direct contact with superfluid helium. Specifically, Ï„e–ph and Ï„es, fitted by the two-temperature model, were equal to 11.6 and 21 ps at 2.15 K, and 10(±2) and 38 ps at 10.5 K, respectively. The obtained value of Ï„e–ph shows that the maximum intermediate frequency bandwidth of NbN hot-electron phonon-cooled mixers operating at TC can reach 16(+4/–3) GHz if one eliminates the bolometric phonon-heating effect.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-6951 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 856  
Permanent link to this record
 

 
Author Danerud, M.; Winkler, D.; Zorin, M.; Trifonov, V.; Karasik, B.; Gershenzon, E. M.; Gol'tsman, G. N.; Lindgren, M. url  doi
openurl 
  Title (down) Picosecond detection of infrared radiation with YBa2Cu3O7-δ thin films Type Conference Article
  Year 1993 Publication Proc. SPIE Abbreviated Journal Proc. SPIE  
  Volume 2104 Issue Pages 183-184  
  Keywords YBCO HTS HEB detectors  
  Abstract Picosecond nonequilibrium and slow bolometric responses from a patterned high-Tc superconducting (HTS) film due toinfrared radiation were investigated using both modulation and pulse techniques. Measurements at A, = 0.85 [tm andA, = 10.6 lim have shown a similar behaviour of the response vs modulation frequency f. The responsivity of the HTS filmbased detector at f ..- 0.6-1 GHz is estimated to be 10-2 – 10-1 V/W.  
  Address  
  Corporate Author Thesis  
  Publisher Spie Place of Publication Editor Birch, J.R.; Parker, T.J.  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference 18th International Conference on Infrared and Millimeter Waves  
  Notes https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=25034664 Approved no  
  Call Number 10.1117/12.2298489 Serial 1653  
Permanent link to this record
 

 
Author Dauler, Eric; Kerman, Andrew; Robinson, Bryan; Yang, Joel; Voronov, Boris; Goltsman, Gregory; Hamilton, Scott; Berggren, Karl url  doi
openurl 
  Title (down) Photon-number-resolution with sub-30-ps timing using multi-element superconducting nanowire single photon detectors Type Journal Article
  Year 2009 Publication J. Modern Opt. Abbreviated Journal J. Modern Opt.  
  Volume 56 Issue 2 Pages 364-373  
  Keywords PNR SSPD; SNSPD; photon-number-resolution; superconducting nanowire single photon detector; timing jitter; system detection efficiency  
  Abstract A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 700  
Permanent link to this record
 

 
Author Zhang, Zijing; Zhang, Jianlong; Wu, Long; Zhang, Yong; Zhao, Yuan; Su, Jianzhong doi  openurl
  Title (down) Photon-counting chirped amplitude modulation lidar using a smart premixing method Type Journal Article
  Year 2013 Publication Opt. Lett. Abbreviated Journal Opt. Lett.  
  Volume 38 Issue 21 Pages 4389-4392  
  Keywords photon-counting detector, lidar, Geiger mode APD, Geiger mode lidar  
  Abstract We proposed a new premixing method for photon-counting chirped amplitude modulation lidar (PCCAML). Earlier studies used the counting results of the returned signal detected by a Geiger mode avalanche photodiode detector (Gm-APD) to mix with the reference signal, called the postmixing method. We use an alternative method known as the premixing method, in which the reference signal is used to directly modulate the sampling gate width of the Gm-APD, and the mixing of the returned signal and the reference signal is completed before the Gm-APD. This premixing method is more flexible and may perform better than the postmixing method in terms of signal-to-noise ratio by cutting down a separated mixer commonly used in the postmixing lidar system. Furthermore, this premixing method lowers the demand for the sampling frequency of the Gm-APD. It allows the use of a much wider modulation bandwidth to improve the range accuracy and resolution. To the best of our knowledge, this is the first report to use the premixing method in the PCCAML system, which will benefit future lidar applications.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1006  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: