|
Lobanov, Y. V., Vakhtomin, Y. B., Pentin, I. V., Khabibullin, R. A., Shchavruk, N. V., Smirnov, K. V., et al. (2018). Characterization of the THz quantum cascade laser using fast superconducting hot electron bolometer. EPJ Web Conf., 195, 04004 (1 to 2).
|
|
|
Fedder, H., Oesterwind, S., Wick, M., Olbrich, F., Michler, P., Veigel, T., et al. (2018). Characterization of electro-optical devices with low jitter single photon detectors – towards an optical sampling oscilloscope beyond 100 GHz. In ECOC (pp. 1–3).
Abstract: We showcase an optical random sampling scope that exploits single photon counting and apply it to characterize optical transceivers. We study single photon detectors with a jitter down to 40 ps. The method can be extended beyond 100 GHz.
|
|
|
Fedorov, G., Gayduchenko, I., Titova, N., Gazaliev, A., Moskotin, M., Kaurova, N., et al. (2018). Carbon nanotube based schottky diodes as uncooled terahertz radiation detectors. Phys. Status Solidi B, 255(1), 1700227 (1 to 6).
Abstract: Despite the intensive development of the terahertz technologies in the last decade, there is still a shortage of efficient room‐temperature radiation detectors. Carbon nanotubes (CNTs) are considered as a very promising material possessing many of the features peculiar for graphene (suppression of backscattering, high mobility, etc.) combined with a bandgap in the carrier spectrum. In this paper, we investigate the possibility to incorporate individual CNTs into devices that are similar to Schottky diodes. The latter is currently used to detect radiation with a frequency up to 50 GHz. We report results obtained with semiconducting (bandgap of about 0.5 eV) and quasi‐metallic (bandgap of few meV) single‐walled carbon nanotubes (SWNTs). Semiconducting CNTs show better performance up to 300 GHz with responsivity up to 100 V W−1, while quasi‐metallic CNTs are shown to operate up to 2.5 THz.
|
|
|
Moskotin, M. V., Gayduchenko, I. A., Goltsman, G. N., Titova, N., Voronov, B. M., Fedorov, G. F., et al. (2018). Bolometric effect for detection of sub-THz radiation with devices based on carbon nanotubes. In J. Phys.: Conf. Ser. (Vol. 1124, 051050 (1 to 5)).
Abstract: In this work we investigate the response on THz radiation of a FET device based on an individual carbon nanotube conductance channel. It was already shown, that the response of such devices can be either of diode rectification origin or of thermoelectric effect origin or of their combination. In this work we demonstrate that at 77K and 8K temperatures strong bolometric effect also makes a significant contribution to the response.
|
|
|
Eletskii, A. V., Sarychev, A. K., Boginskaya, I. A., Bocharov, G. S., Gaiduchenko, I. A., Egin, M. S., et al. (2018). Amplification of a Raman scattering signal by carbon nanotubes. Dokl. Phys., 63(12), 496–498.
Abstract: The effect of Raman scattering (RLS) signal amplification by carbon nanotubes (CNTs) was studied. Single-layered nanotubes were synthesized by the chemical vapor deposition (CVD) method using methane as a carbon-containing gas. The object of study used was water, the Raman spectrum of which is rather well known. Amplification of the Raman scattering signal by several hundred percent was attained in our work. The maximum amplification of a Raman scattering signal was shown to be achieved at an optimal density of nanotubes on a substrate. This effect was due to the scattering and screening of plasmons excited in CNTs by neighboring nanotubes. The amplification mechanism and the possibilities of optimization for this effect were discussed on the basis of the theory of plasmon resonance in carbon nanotubes.
|
|
|
Elezov, M. S., Scherbatenko, M. L., Sych, D. V., & Goltsman, G. N. (2018). Active and passive phase stabilization for the all-fiber Michelson interferometer. In J. Phys.: Conf. Ser. (Vol. 1124, 051014 (1 to 5)).
Abstract: We put forward two methods for phase stabilization in the all-fiber Michelson interferometer. To perform passive phase stabilization, we use a heat bath for all fibers and electro-optical components, and put the interferometer in a hermetic case. To perform active phase stabilization, we monitor output power of the interferometer and develop an electronic feedback control. The phase stabilization methods enable stable interference pattern for several minutes, and can be helpful for the development of the optimal quantum receiver for coherent signals.
|
|
|
Tretyakov, I., Kaurova, N., Voronov, B. M., & Goltsman, G. N. (2018). About effect of the temperature operating conditions on the noise temperature and noise bandwidth of the terahertz range NbN hot-electron bolometers. In Proc. 29th Int. Symp. Space Terahertz Technol. (113).
Abstract: Results of an experimental study of the noise temperature (Tn) and noise bandwidth (NBW) of the superconductor NbN hot-electron bolometer (HEB) mixer as a function of its temperature (Tb) and NbN bridge length are presented. It was determined that the NBW of the mixer is significantly wider at temperatures close to the critical ones (Tc) than are values measured at 4.2 K. The NBW of the mixer measured at the heterodyne frequency of 2.5 THz at temperature Tb close to Tc was ~13 GHz, as compared with 6 GHz at Tb = 4.2 K. This experiment clearly demonstrates the limitation of the thermal flow from the NbN bridge at Tb ≪ Tc for mixers manufactured by the in situ technique. This limitation is close in its nature to the Andreev reflection on the superconductor/metal boundary. In this case, the noise temperature of the studied mixer increased from 1100 to 3800 K.
|
|