Gershenzon, E. M., Gol'tsman, G. N., & Mirskii, G. I. (1987). Submillimeter backward-wave-tube spectrometer-relaxometer. Pribory i Tekhnika Eksperimenta, 30(4), 131–137.
Abstract: A backward-wave-tube (BWT) spectrometer-relaxometer is described that is designed for study of the relaxation characteristics of photoconductors in the wavelength range of 2-0.25 mm – in particular, to measure the relaxation times of the submillimeter photoconductivity of germanium in the range of 10[sup:-4]-10[sup:-9] sec and to determine from these data the concentration of compensating impurities of from 10[sup:10] to 10[sup:14] cm[sup:-3]. The instrument uses the beats of the oscillations of two BWTs and records the amplitude-frequency response of the specimen with variation of the beat frequency from 10[sup:4] to 10[sup:8] Hz with accumulation of the desired signal for less than or equal to1 sec by means of a quadrature synchronous detector. The beat frequency is stabilized and the quadrature voltages of the synchronous detector are formed by means of phase-locked loops.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Semenov, A. D. (1983). Submillimeter backward wave tube spectrometer for measuring superconducting film transmission. Pribory i Tekhnika Eksperimenta, 26(5), 134–137.
Abstract: A spectrometer employing six backward wave tubes is described. It is intended for investigation of superconductors in the 0.2-3 mm range of wave lengths. During the measurement of the transmission spectrum it is possible to determine the energy gap for superconduct1ng films 50 to 4000 A thick. The transmission factor can vary from 10-1 to 10-9. Spectrum of relation of film transmission factors in superconducting and normal states is measured for determining the energy gap 2 Δ. The transmission spectrum obtained by means of a computer for vanadium film 300 A thick is given as an example. The energy gap 2 Δ = 1.4 MeV
|
|
|
Nasr, M. B., Minaeva, O., Goltsman, G. N., Sergienko, A. V., Saleh, B. E., & Teich, M. C. (2008). Submicron axial resolution in an ultrabroadband two-photon interferometer using superconducting single-photon detectors. Opt. Express, 16(19), 15104–15108.
Abstract: We generate ultrabroadband biphotons via the process of spontaneous parametric down-conversion in a quasi-phase-matched nonlinear grating that has a linearly chirped poling period. Using these biphotons in conjunction with superconducting single-photon detectors (SSPDs), we measure the narrowest Hong-Ou-Mandel dip to date in a two-photon interferometer, having a full width at half maximum (FWHM) of approximately 5.7 fsec. This FWHM corresponds to a quantum optical coherence tomography (QOCT) axial resolution of 0.85 µm. Our results indicate that a high flux of nonoverlapping biphotons may be generated, as required in many applications of nonclassical light.
|
|
|
Iomdina, E. N., Goltsman, G. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., & Rusova, A. A. (2016). Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range. J. Biomed. Opt., 21(9), 97002 (1 to 5).
Abstract: An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Keywords: BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology
|
|
|
Ryabchun, S., Tong, C. - Y. E., Blundell, R., Kimberk, R., & Gol'tsman, G. (2007). Study of the effect of microwave radiation on the operation of HEB mixers in the terahertz frequency range. IEEE Trans. Appl. Supercond., 17(2), 391–394.
Abstract: We have investigated the effect of injecting microwave radiation, with a frequency much lower than that corresponding to the energy gap of the superconductor, on the performance of the hot-electron bolometer mixer incorporated into a THz heterodyne receiver. More specifically, we show that exposing the mixer to microwave radiation does not cause a significant rise of the receiver noise temperature and fall of the mixer conversion gain so long as the microwave power is a small fraction of local oscillator power. The injection of a small, but controlled amount of microwave power therefore enables active compensation of local oscillator power and coupling fluctuations which can significantly degrade the gain stability of hot electron bolometer mixer receivers.
|
|