Baselmans, J. J. A., Hajenius, M., Gao, J. R., Baryshev, A., Kooi, J., Klapwijk, T. M., et al. (2005). NbN hot electron bolometer mixers: sensitivity, LO power, direct detection and stability. IEEE Trans. Appl. Supercond., 15(2), 484–489.
Abstract: We demonstrate that the performance of NbN lattice cooled hot electron bolometer mixers depends strongly on the interface quality between the bolometer and the contact structure. Both the receiver noise temperature and the gain bandwidth can be improved by a factor of 2 by cleaning the interface and adding an additional superconducting interlayer to the contact pad. Using this we obtain a double sideband receiver noise temperature of 950 K at 2.5 THz and 4.3 K, using a 0.4/spl times/4 /spl mu/m HEB mixer with a spiral antenna. At the same bias point, we obtain an IF gain bandwidth of 6 GHz. To comply with current demands on THz mixers for use in space based receivers we reduce the device size to 0.15/spl times/1 /spl mu/m and use a twin slot antenna. We report measurements of the noise temperature, LO power requirement, stability and the direct detection effect, using a mixer with a 1.6 THz twin slot antenna and a 1.462 THz solid state LO source with calibrated output power.
|
Palermo, C., Varani, L., Vaissière, J. - C., Millithaler, J. - F., Starikov, E., Shiktorov, P., et al. (2005). Monte Carlo calculation of diffusion coefficient, noise spectral density and noise temperature in HgCdTe. In Proc. AIP Conf. (Vol. 780, pp. 151–154).
|
Goltsman, G. N., Vachtomin, Y. B., Antipov, S. V., Finkel, M. I., Maslennikov, S. N., Polyakov, S. L., et al. (2005). Low-noise NbN phonon-cooled hot-electron bolometer mixers for terahertz heterodyne receivers. In Proc. 9-th WMSCI (Vol. 9, pp. 154–159). International Institute of Informatics and Systemics.
|
Karpov, A., Miller, D., Stern, J. A., Bumble, B., LeDuc, H. G., & Zmuidzinas, J. (2005). Low noise NbTiN 1.25 THz SIS mixer for Herschel Space Observatory. In Proc. 16th Int. Symp. Space Terahertz Technol. (450). Göteborg, Sweden.
|
Hajenius, M., Barends, R., Gao, J. R., Klapwijk, T. M., Baselmans, J. J. A., Baryshev, A., et al. (2005). Local resistivity and the current-voltage characteristics of hot electron bolometer mixers. IEEE Trans. Appl. Supercond., 15(2), 495–498.
Abstract: Hot-electron bolometer devices, used successfully in low noise heterodyne mixing at frequencies up to 2.5 THz, have been analyzed. A distributed temperature numerical model of the NbN bridge, based on a local electron and a phonon temperature, is used to model pumped IV curves and understand the physical conditions during the mixing process. We argue that the mixing is predominantly due to the strongly temperature dependent local resistivity of the NbN. Experimentally we identify the origins of different transition temperatures in a real HEB device, suggesting the importance of the intrinsic resistive transition of the superconducting bridge in the modeling.
|
Vaks, V. L., Kurin, V. V., Pankratov, A. L., & Koshelets, V. P. (2005). Investigation of spectral properties of phase-focked flux flow oscillator. In ISEC (PD-04). Netherlands.
|
Hübers, H. W., Pavlov, S. G., Semenov, A. D., Tredicucci, A., Köhler, R., Mahler, L., et al. (2005). Investigation of a 2.5 THz quantum cascade laser as local oscillator. In Proc. 16th Int. Symp. Space Terahertz Technol. (18). Göteborg, Sweden.
|
Koshelets, V. P., Dmitriev, P. N., Ermakov, A. B., Filippenko, L. V., Koryukin, O. V., Torgashin, M. Y., et al. (2005). Integrated superconducting spectrometer for atmosphere monitoring. Radiophys. Quant. Electron., 48(10-11), 844–850.
|
An, Z., Chen, J. - C., Ueda, T., Komiyama, S., & Hirakawa, K. (2005). Infrared phototransistor using capacitively coupled two-dimensional electron gas layers. Appl. Phys. Lett., 86, 172106-3.
|
Yang, Z. Q., Hajenius, M., Baselmans, J. J. A., Gao, J. R., Klapwijk, T. M., Voronov, B., et al. (2005). Improved sensitivity of NbN hot electron bolometer mixers by vacuum baking. In Proc. 16th Int. Symp. Space Terahertz Technol. (pp. 222–225).
Abstract: We find that the sensitivity of heterodyne receivers based on superconducting hot-electron bolometer (HEB) in- creases by 25 − 30% after baking at 85 o C and in a high vacuum. The devices studied are twin-slot antenna coupled HEB mixers with a small NbN bridge of 1×0.15 μm 2 . The mixer noise temperature, gain, and resistance versus temperature curve of a HEB before and after baking are compared and analyzed. We show that baking reduces the intrinsic noise of the mixer by 37 % and makes the superconducting transition of the bridge and the contacts sharper. We argue that the reduction of the noise is due to the improvement of the transparency of the contact/film interface. The lowest receiver noise temperature of 700 K is measured at a local oscillator frequency of 1.63 THz and a bath temperature of 4.3 K.
|