Gao, J. R., Hajenius, M., Baselmans, J. J. A., Yang, Z. Q., Baryshev, A. M., Barends, R., et al. (2005). Twin-slot antenna coupled NbN hot electron bolometer mixers for space applications. In Proc. 9-th WMSCI (Vol. 9, pp. 148–153). International Institute of Informatics and Systemics.
|
Baselmans, J. J. A., Hajenius, M., Gao, J. R., Baryshev, A., Kooi, J., Klapwijk, T. M., et al. (2004). Hot electron bolometer mixers with improved interfaces: sensitivity, LO power and stability. In Proc. 15th Int. Symp. Space Terahertz Technol. (pp. 17–24).
Abstract: We study twin slot antenna coupled NbN hot electron bolometer mixers with an improved contact structure and a small volume, ranging from 1 µm × 0.1 µm to 2 × 0.3 µm. We obtain a DSB receiver noise temperature of 900 K at 1.6 THz and 940 K at 1.9 THz. To explore the practical usability of such small HEB mixers we evaluate the LO power requirement, the sensitivity and the stability. We find that the LO power requirement of the smallest mixers is reduced to about 240 nW at the Si lens of the mixer. This value is larger than expected from the isothermal technique and the known losses in the lens by a factor of 3-3.5. The stability of these receivers is characterized using a measurement of the Allan Variance. We find an Allan time of 0.5 sec. in an 80 MHz bandwidth. A small increase in stability can be reached by using a higher bias at the expense of a significant amount of sensitivity. The stability is sufficient for spectroscopic applications in a 1 MHz bandwidth at a 1 Hz chopping frequency.
|
Gao, J. R., Hovenier, J. N., Yang, Z. Q., Baselmans, J. J. A., Baryshev, A., Hajenius, M., et al. (2005). Terahertz heterodyne receiver based on a quantum cascade laser and a superconducting bolometer. Appl. Phys. Lett., (86).
|
Baselmans, J. J. A., Baryshev, A., Reker, S. F., Hajenius, M., Gao, J. R., Klapwijk, T. M., et al. (2005). Direct detection effect in small volume hot electron bolometer mixers. Appl. Phys. Lett., 86(16), 163503 (1 to 3).
Abstract: We measure the direct detection effect in a small volume (0.15μm×1μm×3.5nm)(0.15μm×1μm×3.5nm) quasioptical NbN phonon cooled hot electronbolometermixer at 1.6THz1.6THz. We find that the small signal sensitivity of the receiver is underestimated by 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300K300K and 77K77K. Using a 200GHz200GHzbandpass filter at 4.2K4.2K the direct detection effect virtually disappears. This has important implications for the calibration procedure of these receivers in real telescope systems.
|
Hajenius, M., Baselmans, J. J. A., Baryshev, A., Gao, J. R., Klapwijk, T. M., Kooi, J. W., et al. (2006). Full characterization and analysis of a terahertz heterodyne receiver based on a NbN hot electron bolometer. J. Appl. Phys., 100(7), 074507.
|