toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Kawamura, Jonathan; Blundell, Raymond; Tong, C.-Y. Edward; Papa, D. Cosmo; Hunter, Todd R.; Gol'tsman, Gregory; Cherednichenko, Sergei; Voronov, Boris; Gershenzon, Eugene url  openurl
  Title First light with an 800 GHz phonon-cooled HEB mixer receiver Type (up) Conference Article
  Year 1998 Publication Proc. 9th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 9th Int. Symp. Space Terahertz Technol.  
  Volume Issue Pages 35-43  
  Keywords HEB, mixer, LO power, local oscillator power, saturation effect, dynamic range  
  Abstract Phonon-cooled superconductive hot-electron bolometric (HEB) mixers are incorporated in a waveguide receiver designed to operate near 800 Gliz. The mixer elements are thin-film nio- bium nitride microbridges with dimensions of 4 nm thickness, 0.2 to 0.3 p.m in length and 2 jun in width. At 780 GHz the best receiver noise temperature is 840 K (DSB). The mixer IF bandwidth is 2.0 GHz, the absorbed LO power is —0.1 1.1W. A fixed-tuned version of the re- ceiver was installed at the Submillimeter Telescope Observatory on Mt. Graham, Arizona, to conduct astronomical observations. These observations represent the first time that a receiver incorporating any superconducting HEB mixer has been used to detect a spectral line of celes- tial origin.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Pasadena, California, USA Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 572  
Permanent link to this record
 

 
Author Cao, Aiqin; Jiang, L.; Chen, S.H.; Antipov, S.V.; Shi, S.C. doi  openurl
  Title IF gain bandwidth of a quasi-optical NbN superconducting HEB mixer Type (up) Conference Article
  Year 2007 Publication Proc. International conference on microwave and millimeter wave technology Abbreviated Journal Proc. ICMMT  
  Volume Issue Pages 1-3  
  Keywords HEB, mixer, gain bandwidth  
  Abstract In this paper, the intermediate frequency (IF) gain bandwidth of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer is investigated at 500 GHz with an IF system incorporating with a frequency down-converting scheme which is able to sweep the IF signal in a frequency range of 0.3-4 GHz. The IF gain bandwidth of the device is measured to be 1.5 GHz when it is biased at a voltage of the minimum noise temperature, and becomes larger when the bias voltage increases.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Builin Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ lobanovyury @ Serial 575  
Permanent link to this record
 

 
Author van't Klooster, K.; Myasnikova, S. E.; Parshin, V. V.; Kasparek, W. openurl 
  Title Results of reflection loss measurements of sample material for radio astronomy telescope antenna for Planck Project Type (up) Conference Article
  Year 2004 Publication Proc. 14th international crimean conference on microwave and telecommunication technology Abbreviated Journal  
  Volume Issue Pages 753-755  
  Keywords mirror, reflection index, emissivity, Fabry-Perot interferometer, space observatory, terahertz, THz  
  Abstract Advanced radio telescope antennas for space applications are realised by the use of stable composite materials, which are lighter in general than various metal realisations. Reflectivity measurements have been carried out on high technology samples for the Planck radio telescope. Highly accurate results have been obtained at the Applied Physics Institute in Nizhny Novgorod, and an independent measurement with a totally different setup at the University of Stuttgart confirmed that one of the samples showed a strange behaviour. Moreover, it confirmed the high accuracy of the testing method.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 579  
Permanent link to this record
 

 
Author Shitov, S. V.; Inatani, J.; Shan, W.-L.; Takeda, M; Wang, Z.; Uvarov, A. V.; Ermakov, A. B.; Uzawa, Y. openurl 
  Title Measurement of emissivity of the ALMA antenna panel at 840 GHz using NbN-based heterodyne SIS receiver Type (up) Conference Article
  Year 2008 Publication Proc. 19th Int. Symp. Space Terahertz Technol. Abbreviated Journal  
  Volume Issue Pages 263-266  
  Keywords SIS mixer, reflection, emissivity, mirror, space telescope, space observatory  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 580  
Permanent link to this record
 

 
Author Myasnikova, S. E.; Parshin, V.V.; van't Klooster, K.; Valsecchi, G. openurl 
  Title Reflectivity of antenna and mirrors reflectors at 110 and 200 GHz Type (up) Conference Article
  Year 2003 Publication Proc. 4th international conference on antenna theory and techniques Abbreviated Journal  
  Volume 2 Issue Pages 624- 627  
  Keywords mirror, reflection index, emissivity, reflectivity, mirror, Fabry-Perot interferometer, subterahertz, subTHz  
  Abstract Reflectivity (reflection loss) investigations of nickel samples with different types of surface finish, with and without rhodium coating, have been carried out in the 110-200 GHz frequency range on an installation developed in the Applied Physics Institute of Russia. The reflectivity measurements of high quality silver coated and gold coated mirrors are also presented. The reflectivity (reflection loss) investigations of some carbon fibre samples with and without aluminium coating have been made. Results are interesting, in view of the anisotropy of the carbon fibre material.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 582  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: