|
Driessen, E. F. C., Braakman, F. R., Reiger, E. M., Dorenbos, S. N., Zwiller, V., & de Dood, M. J. A. (2009). Impedance model for the polarization-dependent optical absorption of superconducting single-photon detectors. Eur. Phys. J. Appl. Phys., 47, 10701.
Abstract: We measured the single-photon detection efficiency of NbN superconducting single-photon detectors as a function of the polarization state of the incident light for different wavelengths in the range from 488 nm to 1550 nm. The polarization contrast varies from ~% at 488 nm to~0% at 1550 nm, in good agreement with numerical calculations. We use an optical-impedance model to describe the absorption for polarization parallel to the wires of the detector. For the extremely lossy NbN material, the absorption can be kept constant by keeping the product of layer thickness and filling factor constant. As a consequence, the maximum possible absorption is independent of filling factor. By illuminating the detector through the substrate, an absorption efficiency of ~0% can be reached for a detector on Si or GaAs, without the need for an optical cavity.
|
|
|
Anosov, A. A., Barabanenkov, Y. N., Kazanskii, A. S., Less, Y. A., & Sharakshane, A. S. (2009). The inverse problem of acoustothermography with correlation reception of thermal acoustic radiation. Acoust. Phys., 55(1), 114–119.
Abstract: For the one-dimensional inverse problem of acoustothermography with correlation reception of thermal acoustic radiation, an integral equation is presented and experimentally verified. A method of solving the inverse problem is proposed. The method is based on combining the correlation functions of thermal acoustic radiation that were obtained for different distances between the receivers.
|
|
|
Wild, W., Kardashev, N. S., Likhachev, S. F., Babakin, N. G., Arkhipov, V. Y., Vinogradov, I. S., et al. (2009). Millimetron—a large Russian-European submillimeter space observatory. Exp. Astron., 23(1), 221–244.
Abstract: Millimetron is a Russian-led 12 m diameter submillimeter and far-infrared space observatory which is included in the Space Plan of the Russian Federation for launch around 2017. With its large collecting area and state-of-the-art receivers, it will enable unique science and allow at least one order of magnitude improvement with respect to the Herschel Space Observatory. Millimetron will be operated in two basic observing modes: as a single-dish observatory, and as an element of a ground-space very long baseline interferometry (VLBI) system. As single-dish, angular resolutions on the order of 3 to 12 arc sec will be achieved and spectral resolutions of up to a million employing heterodyne techniques. As VLBI antenna, the chosen elliptical orbit will provide extremely large VLBI baselines (beyond 300,000 km) resulting in micro-arc second angular resolution.
|
|
|
Treuttel, J., Thomas, B., Maestrini, A., Wang, H., Alderman, B., Siles, J. V., et al. (2009). A 380 GHz sub-harmonic mixer using MMIC foundry based Schottky diodes transferred onto quartz substrate. In Proc. 20th Int. Symp. Space Terahertz Technol.. Charlottesville, Virginia, USA.
|
|
|
Ryabchun, S. A., Tretyakov, I. V., Finkel, M. I., Maslennikov, S. N., Kaurova, N. S., Seleznev, V. A., et al. (2009). NbN phonon-cooled hot-electron bolometer mixer with additional diffusion cooling. In Proc. 20th Int. Symp. Space Terahertz Technol. (pp. 151–154). Charlottesville, USA.
|
|