Seki, T., Shibata, H., Takesue, H., Tokura, Y., & Imoto, N. (2010). Comparison of timing jitter between NbN superconducting single-photon detector and avalanche photodiode. Phys. C, 470(20), 1534–1537.
Abstract: We report the pulse-to-pulse timing jitter measurement of a niobium nitride (NbN) superconducting single-photon detector (SSPD) and an InGaAs avalanche photodiode (APD) at 1550-nm wavelength. A direct comparison of their timing jitter was performed by using the same experimental configuration to measure both detectors. The measured jitter of the SSPD and the APD are 75 and 84 ps at full-width at half-maximum (FWHM), and 138 and 384 ps at full-width at tenth-maximum (FWTM), respectively. The jitter of the SSPD remains small at FWTM while that of APD is wide. We also estimated the transmission distances and secure key generation rates for fiber-based quantum key distribution (QKD) which uses these detectors. The estimated transmission distances of the APD are 86 km and 107 km with respect to 1 ns and 100 ps time windows, respectively, and those of the SSPD are 125 km and 172 km with respect to 1 ns and 100 ps time windows, respectively. This estimation indicates the SSPDЃfs advantages for QKD compared to the APD.
|
Shah, J., Pinczuk, A., Gossard, A. C., & Wiegmann, W. (1985). Energy-loss rates for hot electrons and holes in GaAs quantum wells. Phys. Rev. Lett., 54, 2045–2048.
Abstract: We report the first direct determination of carrier-energy-loss rates in a semiconductor. These measurements provide fundamental insight into carrier-phonon interactions in semiconductors. Unexpectedly large differences are found in the energy-loss rates for electrons and holes in GaAs/AlGaAs quantum wells. This large difference results from an anomalously low electron-energy-loss rate, which we attribute to the presence of nonequilibrium optical phonons rather than the effects of reduced dimensionality or dynamic screening.
|
Shaha, J., Pinczukb, A., Gossardb, A. C., & Wiegmannb, W. (1985). Hot carrier energy loss rates in GaAs quantum wells: large differences between electrons and holes. Phys. B+C, 134(1-3), 174–178.
Abstract: The first direct and separate determination of the hot electron and hot hole energy loss rates to the lattice shows unexpectedly large differences between electrons and holes in GaAs quantum wells. This large difference results from an anomalously low electron energy loss rate, which we attribute to the presence of non-equilibrium optical phonon rather than the effects of reduced dimensionality or dynamic screening. A model calculation of hot phonon effects is presented.
|
Ryabchun, S., Tong, C. - Y. E., Paine, S., Lobanov, Y., Blundell, R., & Goltsman, G. (2009). Temperature resolution of an HEB receiver at 810 GHz. IEEE Trans. Appl. Supercond., 19(3), 293–296.
Abstract: We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation.
|
Tretyakov, I., Ryabchun, S., Finkel, M., Maslennikova, A., Kaurova, N., Lobastova, A., et al. (2011). Low noise and wide bandwidth of NbN hot-electron bolometer mixers. Appl. Phys. Lett., 98, 033507 (1 to 3).
Abstract: We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.
|