|
Zubkova, E., An, P., Kovalyuk, V., Korneev, A., Ferrari, S., Pernice, W., et al. (2018). Optimization of contra-directional coupler based on silicon nitride Bragg rib waveguide. In J. Phys.: Conf. Ser. (Vol. 1124, 051048).
Abstract: We report on the development and fabrication of a contra-directional coupler based on the Bragg waveguide on Si3N4 platform. Transmitted and reflected by the contra-directional coupler spectra were measured. The reflected spectra exactly matches the one notched by the main channel of the coupler. Losses are about 3dB, coupling to the directing branch of the coupler is practically lossless. FWHM of the transmitted (reflected) spectra is 3.46 nm.
|
|
|
Moskotin, M. V., Gayduchenko, I. A., Goltsman, G. N., Titova, N., Voronov, B. M., Fedorov, G. F., et al. (2018). Bolometric effect for detection of sub-THz radiation with devices based on carbon nanotubes. In J. Phys.: Conf. Ser. (Vol. 1124, 051050 (1 to 5)).
Abstract: In this work we investigate the response on THz radiation of a FET device based on an individual carbon nanotube conductance channel. It was already shown, that the response of such devices can be either of diode rectification origin or of thermoelectric effect origin or of their combination. In this work we demonstrate that at 77K and 8K temperatures strong bolometric effect also makes a significant contribution to the response.
|
|
|
Golikov, A., Kovalyuk, V., An, P., Zubkova, E., Ferrari, S., Pernice, W., et al. (2018). Silicon nitride nanophotonic circuit for on-chip spontaneous four-wave mixing. In J. Phys.: Conf. Ser. (Vol. 1124, 051051).
Abstract: Here we present an integrated nanophotonic circuit for on-chip spontaneous four-wave mixing. The fabricated device includes an O-ring resonator, a Bragg noch-filter as well as a nine-channel arrayed waveguide gratings (AWG) operated in the C-band wavelength range (1550 nm). The measured optical losses of the device (-6.8 dB) as well as a high Q-factor (> 1.2×105) shows a good potential for realizing the spontaneous four-wave mixing on the silicon nitride chip.
|
|
|
Prokhodtsov, A., An, P., Kovalyuk, V., Zubkova, E., Golikov, A., Korneev, A., et al. (2018). Optimization of on-chip photonic delay lines for telecom wavelengths. In J. Phys.: Conf. Ser. (Vol. 1124, 051052).
Abstract: In this work, we experimentally studied optical delay lines on silicon nitride platform for telecomm wavelength (1550 nm). We modeled the group delay time and fabricated spiral optical delay lines with different waveguide widths and radii as well as measured their transmission. For the half etched rib waveguides we achieved the losses in the range of 3 dB/cm.
|
|
|
Matyushkin, Y. E., Gayduchenko, I. A., Moskotin, M. V., Goltsman, G. N., Fedorov, G. E., Rybin, M. G., et al. (2018). Graphene-layer and graphene-nanoribbon FETs as THz detectors. In J. Phys.: Conf. Ser. (Vol. 1124, 051054).
Abstract: We report on detection of sub-THz radiation (129-430 GHz) using graphene based asymmetric field-effect transistor (FET) structures with different channel geometry: monolayer graphene, graphene nanoribbons. In all devices types we observed the similar trends of response on sub-THz radiation. The response fell with increasing frequency at room temperature, but increased with increasing frequency at 77 K. Our calculations show that the change in the trend of the frequency dependence at 77 K is associated with the appearance of plasma waves in the graphene channel. Unusual properties of p-n junctions in graphene are highlighted using devices of special geometry.
|
|
|
Baksheeva, K., Vdovydchenko, A., Gorshkov, K., Ozhegov, R., Kinev, N., Koshelets, V., et al. (2019). Study of human skin radiation in the terahertz frequency range. In J. Phys.: Conf. Ser. (Vol. 1410, 012076 (1 to 5)).
Abstract: The radiation of human skin in the terahertz frequency range under the influence of mental stresses has been studied in the current work. An experimental setup for observation of changes in human skin radiation, which occur under the influence of psychological stresses, by means of a superconducting integrated receiver has been developed. More than 30 volunteers participate in these studies, which allows us to verify presence of correlation between the signals from the superconducting integrated terahertz receiver and other sensors that monitor human mental stress.
|
|
|
Moshkova, M., Morozov, P., Divochiy, A., Vakhtomin, Y., & Smirnov, K. (2019). Large active area superconducting single photon detector. In J. Phys.: Conf. Ser. (Vol. 1410, 012139).
Abstract: We present development of large active area superconducting single-photon detectors well coupled with standard 50 μm-core multi-mode fiber. The sensitive area of the SSPD is patterned using the photon-number-resolving design and occupies an area of 40×40 μm2. Using this approach, we have obtained excellent specifications: system detection efficiency of 47% measured using a 900 nm laser and low dark count rate of 100 cps. The main advantages of the approach presented are a very short dead time of the detector of 22 ns and FWHM jitter value of about 130 ps.
|
|
|
Manova, N. N., Smirnov, E. O., Korneeva, Y. P., Korneev, A. A., & Goltsman, G. N. (2019). Superconducting photon counter for nanophotonics applications. In J. Phys.: Conf. Ser. (Vol. 1410, 012147 (1 to 5)).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
|
|
Polyakova, M. I., Florya, I. N., Semenov, A. V., Korneev, A. A., & Goltsman, G. N. (2019). Extracting hot-spot correlation length from SNSPD tomography data. In J. Phys.: Conf. Ser. (Vol. 1410, 012166 (1 to 4)).
Abstract: We present data of quantum detector tomography for the samples specifically optimized for this problem. Using this method, we take results of hot-spot correlation length of 17 ± 2 nm.
|
|
|
Zubkova, E., Golikov, A., An, P., Kovalyuk, V., Korneev, A., Ferrari, S., et al. (2019). CWDM demultiplexer using anti-reflection, contra-directional couplers based on silicon nitride rib waveguide. In J. Phys.: Conf. Ser. (Vol. 1410, 012179).
Abstract: We report on the development and fabrication of a 9-channel coarse wavelength-division multiplexing for telecommunication wavelengths (1550 nm) using anti-reflection contra-directional couplers, based on silicon nitride (Si3N4) rib waveguide. The transmitted and reflected spectrum in each channel of the demultiplexer were measured. The average full width at half maximum of the transmitted (reflected) spectra is about 3 nm.
|
|
|
Komrakova, S., Javadzade, J., Vorobyov, V., Bolshedvorskii, S., Soshenko, V., Akimov, A., et al. (2019). CMOS compatible nanoantenna-nanodiamond integration. In J. Phys.: Conf. Ser. (Vol. 1410, 012180).
Abstract: Here we demonstrate CMOS compatible method to deterministically produce nanoantenna with nanodiamonds systems on example of bull-eye antenna on top of on hyperbolic metamaterials. We study the statistics of the placement of nanodiamonds and measure the fluorescence lifetime and the second-order correlation function of NV-centers inside nanodiamonds.
|
|
|
Kuzin, A., Kovalyuk, V., Golikov, A., Prokhodtsov, A., Marakhin, A., Ferrari, S., et al. (2019). Efficiency of focusing grating couplers versus taper length and angle. In J. Phys.: Conf. Ser. (Vol. 1410, 012181).
Abstract: Here we experimentally studied dependence of a focusing grating coupler efficiency versus taper length and angle on silicon nitride platform. As a result, we obtained a dependence for the efficiency of a focusing grating coupler on the parameters of the taper length and angle.
|
|
|
Titova, N., Gayduchenko, I. A., Moskotin, M. V., Fedorov, G. F., & Goltsman, G. N. (2019). Carbon nanotube based terahertz radiation detectors. In J. Phys.: Conf. Ser. (Vol. 1410, 012208 (1 to 5)).
Abstract: In this paper, we study terahertz detectors based on single quasimetallic carbon nanotubes (CNT) with asymmetric contacts and different metal pairs. We demonstrate that, depending on the contact metallization of the device, various detection mechanisms are manifested.
|
|
|
Manova, N. N., Simonov, N. O., Korneeva, Y. P., & Korneev, A. A. (2020). Developing of NbN films for superconducting microstrip single-photon detector. In J. Phys.: Conf. Ser. (Vol. 1695, 012116 (1 to 5)).
Abstract: We optimized NbN films on a Si substrate with a buffer SiO2 layer to produce superconducting microstrip single-photon detectors with saturated dependence of quantum efficiency (QE) versus normalized bias current. We varied thickness of films and observed the maximum QE saturation for device based on the thinner film with the lowest ratio RS300/RS20.
|
|
|
Venediktov, I. O., Elezov, M. S., Prokhodtsov, A. I., Kovalyuk, V. V., An, P. P., Golikov, A. D., et al. (2020). Study of microheater’s phase modulation for on-chip Kennedy receiver. In J. Phys.: Conf. Ser. (Vol. 1695, 012117).
Abstract: In this work we describe phase modulators for several Mach-Zehnder interferometers (MZI) on silicon nitride platform for telecomm wavelength (1550 nm). We obtained current-voltage and phase-voltage curves for these modulators. MZI are needed for experimental realisation of various quantum receivers that can distinguish weak coherent states of light with extremely low error. Thermo-optical (TO) modulation is ensured by microheaters on one of the arms of MZI, which enables the change of the refractive index of the material with temperature. This approach allows to apply the necessary voltage to the golden microheaters to obtain the required phase change. For the on-chip microheaters we demonstrate the dependence of the phase shift on the voltage applied to our on-chip microheaters.
|
|