|
Zolotov, P., Vakhtomin, Y., Divochiy, A., Seleznev, V., Morozov, P., & Smirnov, K. (2013). High-efficiency single-photon detectors based on NbN films.
Abstract: We present our resent results in development and testing of Superconducting Single-Photon Detectors (SSPD) with detection efficiencies greater than 85%. High values of obtained results are assigned to proposed design of the detector with integrated resonator structure, including two-layer optical cavity and anti-reflective coating (ARC).
|
|
|
Bondarenko, O. I., Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1972). Measurement of the width of the cyclotron resonance line of n-type Ge in quantizing magnetic fields. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 6, 362–363.
|
|
|
Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1976). Scattering of electrons by charged impurities in Ge under cyclotron resonance conditions. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 10, 1379–1383.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Kagane, M. L. (1978). Observation of free carrier resonances in p-type germanium at submillimeter wavelengths. Sov. Phys. Solid State, 20(4), 573–579.
Abstract: The spectrum of hole resonances in pure p-Ge for submillimetre in quantizing magnetic fields has been studied and identified. Measurements of photoconductivity spectra of p-Ge were made in the wave range lambda = 2-0.3 mm at temp. of 4.2-15 deg K in magnetic fields H up to 40 Measurements at various frequencies showed that the position of a series of characteristic resonances depends on the frequency of the illumination. This is in line with theoretical conclusions about the effective mass of the carriers increasing with rise in the magnetic field as a result of the interaction of the edge of the valency band with the split spin-orbital interaction of the sub 7 exp + band and the conduction band. The relative intensity of the quantum resonance lines of the free holes depends on the excitation conditions.
|
|
|
Hübers, H. - W., Semenov, A., Richter, H., Birk, M., Krocka, M., Mair, U., et al. (2002). Terahertz heterodyne receiver with a hot-electron bolometer mixer. In J. Wold, & J. Davidson (Eds.), Proc. Far-IR, Sub-mm, and mm Detector Technology Workshop.
Abstract: During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA)[1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.
|
|