Kovalyuk, V., Kahl, O., Ferrari, S., Vetter, A., Lewes-Malandrakis, G., Nebel, C., et al. (2018). On-chip single-photon spectrometer for visible and infrared wavelength range. In J. Phys.: Conf. Ser. (Vol. 1124, 051045).
Abstract: Here we show our latest progress in the field of a single-photon spectrometer for the visible and infrared wavelengths ranges implementation. We consider three different on-chip approaches: a coherent spectrometer with a low power of the heterodyne, a coherent spectrometer with a high power of the heterodyne, and an eight-channel single-photon spectrometer for direct detection. Along with high efficiency, spectrometers show high detection efficiency and temporal resolution through the use of waveguide integrated superconducting nanowire single-photon detectors.
|
|
|
Komrakova, S., Javadzade, J., Vorobyov, V., Bolshedvorskii, S., Soshenko, V., Akimov, A., et al. (2018). On-chip controlled placement of nanodiamonds with a nitrogen-vacancy color centers (NV). In J. Phys.: Conf. Ser. (Vol. 1124, 051046 (1 to 4)).
Abstract: Here we studied the fabrication technique of a kilopixel array of nanodiamonds with a nitrogen-vacancy color centers (NV) on top of the chip and measured the second-order correlation function deep, clearly demonstrated the presence of single-photon sources. The controlled position of nanodiamonds, determined from the measurement of second-order correlation fiction, was realize, as well as the yield of optimized technique equals 12.5% is shown.
|
|
|
An, P., Kovalyuk, V., Golikov, A., Zubkova, E., Ferrari, S., Korneev, A., et al. (2018). Experimental optimisation of O-ring resonator Q-factor for on-chip spontaneous four wave mixing. In J. Phys.: Conf. Ser. (Vol. 1124, 051047).
Abstract: In this paper we experimentally studied the influence of geometrical parameters of the planar O-ring resonators on its Q-factor and losses. We systematically changed the gap between the bus waveguide and the ring, as well as the width of the ring. We found the highest Q = 5×105 for gap 2.0 μm and the ring width 2 μm. This work is important for further on-chip SFWM applications since the generation rate of the biphoton field strongly depends on the quality factor as Q3
|
|
|
Zubkova, E., An, P., Kovalyuk, V., Korneev, A., Ferrari, S., Pernice, W., et al. (2018). Optimization of contra-directional coupler based on silicon nitride Bragg rib waveguide. In J. Phys.: Conf. Ser. (Vol. 1124, 051048).
Abstract: We report on the development and fabrication of a contra-directional coupler based on the Bragg waveguide on Si3N4 platform. Transmitted and reflected by the contra-directional coupler spectra were measured. The reflected spectra exactly matches the one notched by the main channel of the coupler. Losses are about 3dB, coupling to the directing branch of the coupler is practically lossless. FWHM of the transmitted (reflected) spectra is 3.46 nm.
|
|
|
Moskotin, M. V., Gayduchenko, I. A., Goltsman, G. N., Titova, N., Voronov, B. M., Fedorov, G. F., et al. (2018). Bolometric effect for detection of sub-THz radiation with devices based on carbon nanotubes. In J. Phys.: Conf. Ser. (Vol. 1124, 051050 (1 to 5)).
Abstract: In this work we investigate the response on THz radiation of a FET device based on an individual carbon nanotube conductance channel. It was already shown, that the response of such devices can be either of diode rectification origin or of thermoelectric effect origin or of their combination. In this work we demonstrate that at 77K and 8K temperatures strong bolometric effect also makes a significant contribution to the response.
|
|
|
Golikov, A., Kovalyuk, V., An, P., Zubkova, E., Ferrari, S., Pernice, W., et al. (2018). Silicon nitride nanophotonic circuit for on-chip spontaneous four-wave mixing. In J. Phys.: Conf. Ser. (Vol. 1124, 051051).
Abstract: Here we present an integrated nanophotonic circuit for on-chip spontaneous four-wave mixing. The fabricated device includes an O-ring resonator, a Bragg noch-filter as well as a nine-channel arrayed waveguide gratings (AWG) operated in the C-band wavelength range (1550 nm). The measured optical losses of the device (-6.8 dB) as well as a high Q-factor (> 1.2×105) shows a good potential for realizing the spontaneous four-wave mixing on the silicon nitride chip.
|
|
|
Prokhodtsov, A., An, P., Kovalyuk, V., Zubkova, E., Golikov, A., Korneev, A., et al. (2018). Optimization of on-chip photonic delay lines for telecom wavelengths. In J. Phys.: Conf. Ser. (Vol. 1124, 051052).
Abstract: In this work, we experimentally studied optical delay lines on silicon nitride platform for telecomm wavelength (1550 nm). We modeled the group delay time and fabricated spiral optical delay lines with different waveguide widths and radii as well as measured their transmission. For the half etched rib waveguides we achieved the losses in the range of 3 dB/cm.
|
|
|
Matyushkin, Y. E., Gayduchenko, I. A., Moskotin, M. V., Goltsman, G. N., Fedorov, G. E., Rybin, M. G., et al. (2018). Graphene-layer and graphene-nanoribbon FETs as THz detectors. In J. Phys.: Conf. Ser. (Vol. 1124, 051054).
Abstract: We report on detection of sub-THz radiation (129-430 GHz) using graphene based asymmetric field-effect transistor (FET) structures with different channel geometry: monolayer graphene, graphene nanoribbons. In all devices types we observed the similar trends of response on sub-THz radiation. The response fell with increasing frequency at room temperature, but increased with increasing frequency at 77 K. Our calculations show that the change in the trend of the frequency dependence at 77 K is associated with the appearance of plasma waves in the graphene channel. Unusual properties of p-n junctions in graphene are highlighted using devices of special geometry.
|
|
|
Baksheeva, K., Vdovydchenko, A., Gorshkov, K., Ozhegov, R., Kinev, N., Koshelets, V., et al. (2019). Study of human skin radiation in the terahertz frequency range. In J. Phys.: Conf. Ser. (Vol. 1410, 012076 (1 to 5)).
Abstract: The radiation of human skin in the terahertz frequency range under the influence of mental stresses has been studied in the current work. An experimental setup for observation of changes in human skin radiation, which occur under the influence of psychological stresses, by means of a superconducting integrated receiver has been developed. More than 30 volunteers participate in these studies, which allows us to verify presence of correlation between the signals from the superconducting integrated terahertz receiver and other sensors that monitor human mental stress.
|
|
|
Manova, N. N., Smirnov, E. O., Korneeva, Y. P., Korneev, A. A., & Goltsman, G. N. (2019). Superconducting photon counter for nanophotonics applications. In J. Phys.: Conf. Ser. (Vol. 1410, 012147 (1 to 5)).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
|