|
Gershenzon, E. M., Gol'tsman, G. N., & Kagane, M. L. (1978). Observation of free carrier resonances in p-type germanium at submillimeter wavelengths. Sov. Phys. Solid State, 20(4), 573–579.
Abstract: The spectrum of hole resonances in pure p-Ge for submillimetre in quantizing magnetic fields has been studied and identified. Measurements of photoconductivity spectra of p-Ge were made in the wave range lambda = 2-0.3 mm at temp. of 4.2-15 deg K in magnetic fields H up to 40 Measurements at various frequencies showed that the position of a series of characteristic resonances depends on the frequency of the illumination. This is in line with theoretical conclusions about the effective mass of the carriers increasing with rise in the magnetic field as a result of the interaction of the edge of the valency band with the split spin-orbital interaction of the sub 7 exp + band and the conduction band. The relative intensity of the quantum resonance lines of the free holes depends on the excitation conditions.
|
|
|
Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1976). Scattering of electrons by charged impurities in Ge under cyclotron resonance conditions. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 10, 1379–1383.
|
|
|
Bondarenko, O. I., Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1972). Measurement of the width of the cyclotron resonance line of n-type Ge in quantizing magnetic fields. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 6, 362–363.
|
|
|
Семенов, А. В., Корнеев, А. А., Лобанов, Ю. В., Корнеева, Ю. П., Рябчун, С. А., Лаврова, О. С., et al. (2012). Поляризация электромагнитной волны вблизи фокуса зеркала и системы зеркал в субтерагерцовом диапазоне частот. Современные проблемы науки и образования, (2).
Abstract: Рассмотрено влияние оптической системы телескопа на поляризацию принимаемого электромагнитного сигнала. Описано изменение поляризации луча при отражении от произвольно ориентированной поверхности зеркала. Учтены искажения поляризации, обусловленные как отклонением лучей от первоначального направления, так и различием в коэффициентах отражения для разных поляризаций в случае неидеального отражения. В рамках метода Френеля получены оценочные формулы, дающие отношение амплитуд поля с исходной поляризацией и с поляризацией, перпендикулярной исходной, вблизи фокальной точки оптической системы. Формулы выведены для нескольких практически важных случаев, в том числе для параболического зеркала и системы двух зеркал. Оценена верхняя граница поляризационных искажений в пределах кружка Эйри. Полученные оценки согласуются с результатами численного расчёта для двухзеркального радиотелескопа субтерагерцового диапазона.
|
|
|
Казаков, А. Ю., Кардакова, А. И., Селиверстов, С. В., Горшков, К. Н., Дивочий, А. В., Финкель, М. И., et al. (2012). Возможность применения сверхпроводниковых материалов в качестве отражающего покрытия холодного зеркала телескопа субмиллиметрового диапазона. Совр. проб. науки и обр., (3), 1–5.
|
|
|
Verevkin, A., Pearlman, A., Slysz, W., Zhang, J., Currie, M., Korneev, A., et al. (2004). Ultrafast superconducting single-photon detectors for near-infrared-wavelength quantum communications. J. Modern Opt., 51(9-10), 1447–1458.
Abstract: The paper reports progress on the design and development of niobium-nitride, superconducting single-photon detectors (SSPDs) for ultrafast counting of near-infrared photons for secure quantum communications. The SSPDs operate in the quantum detection mode, based on photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-width superconducting stripe. The devices are fabricated from 3.5 nm thick NbN films and kept at cryogenic (liquid helium) temperatures inside a cryostat. The detector experimental quantum efficiency in the photon-counting mode reaches above 20% in the visible radiation range and up to 10% at the 1.3–1.55 μn infrared range. The dark counts are below 0.01 per second. The measured real-time counting rate is above 2 GHz and is limited by readout electronics (the intrinsic response time is below 30 ps). The SSPD jitter is below 18 ps, and the best-measured value of the noise-equivalent power (NEP) is 2 × 10−18 W/Hz1/2. at 1.3 μm. In terms of photon-counting efficiency and speed, these NbN SSPDs significantly outperform semiconductor avalanche photodiodes and photomultipliers.
|
|
|
Svechnikov, S. I., Antipov, S. V., Vakhtomin, Y. B., Goltsman, G. N., Gershenzon, E. M., Cherednichenko, S. I., et al. (2001). Conversion and noise bandwidths of terahertz NbN hot-electron bolometer mixers. Physics of Vibrations, 9(3), 205–210.
|
|
|
Antipov, S. V., Svechnikov, S. I., Smirnov, K. V., Vakhtomin, Y. B., Finkel, M. I., Goltsman, G. N., et al. (2001). Noise temperature of quasioptical NbN hot electron bolometer mixers at 900 GHz. Physics of Vibrations, 9(4), 242–245.
|
|