toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links (down)
Author Semenov, A.; Engel, A.; Il'in, K.; Gol'tsman, G.; Siegel, M.; Hübers, H.-W. url  doi
openurl 
  Title Ultimate performance of a superconducting quantum detector Type Journal Article
  Year 2003 Publication Eur. Phys. J. Appl. Phys. Abbreviated Journal Eur. Phys. J. Appl. Phys.  
  Volume 21 Issue 3 Pages 171-178  
  Keywords NbN SSPD, SNSPD  
  Abstract We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1286-0042 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 534  
Permanent link to this record
 

 
Author Aksaev, E. E.; Gershenzon, E.M.; Gol'tsman, G. N.; Mirskij, G. I.; Semenov, A. D. url  openurl
  Title Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution Type Journal Article
  Year 1991 Publication Pribory i Tekhnika Eksperimenta Abbreviated Journal Pribory i Tekhnika Eksperimenta  
  Volume 34 Issue 2 Pages 125-131  
  Keywords BWO, applications  
  Abstract The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0032-8162 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1683  
Permanent link to this record
 

 
Author Verevkin, A.; Gershenzon, E. M.; Gol'tsman, G. N.; Ptitsina, N. G.; Chulkova, G. M.; Smirnov, K. S.; Sobolewski, R. url  openurl
  Title Direct measurements of energy relaxation times in two-dimensional structures under quasi-equilibrium conditions Type Conference Article
  Year 2002 Publication Mater. Sci. Forum Abbreviated Journal Mater. Sci. Forum  
  Volume 384-3 Issue Pages 107-116  
  Keywords 2DEG, AlGaAs/GaAs  
  Abstract A new microwave technique was successfully applied for direct studies of energy relaxation times in two-dimensional AlGaAs/GaAs structures under quasi-equilibrium conditions in the nanosecond and picosecond time scale. We report our results of energy relaxation time measurements in the temperature range 1.6-50 K, in quantum Hall effect regime in magnetic fields up to 4 T.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference Materials Science Forum  
  Notes Approved no  
  Call Number Serial 1536  
Permanent link to this record
 

 
Author Hübers, Heinz-Wilhelm; Semenov, A.; Richter, H.; Smirnov, K.; Gol'tsman, G.; Voronov, B. url  openurl
  Title Phonon cooled far-infrared hot electron bolometer mixer Type Abstract
  Year 2002 Publication NASA/ADS Abbreviated Journal NASA/ADS  
  Volume Issue Pages  
  Keywords NbN HEB mixers  
  Abstract Heterodyne receivers for applications in astronomy need quantum-limited sensitivity. At frequencies above 1.4 THz superconducting hot electron bolometers (HEB) can be used to achieve this goal. We present results of the development of a quasi-optical phonon-cooled NbN HEB mixer for GREAT, the German heterodyne receiver for SOFIA. Different mixers with logarithmic spiral and double slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern at several frequencies between 0.7 THz and 5.2 THz. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 16 dB. The response of the mixer was linear up to 400 K load temperature. This performance was verified by measuring an emission line of methanol at 2.5 THz. The results demonstrate that the NbN HEB is very well suited as a mixer for FIR heterodyne receivers.  
  Address Monterey, CA  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference Far-IR, Sub-mm & MM Detector Technology Workshop, 1-3 April 2002  
  Notes id.37 Approved no  
  Call Number Serial 1534  
Permanent link to this record
 

 
Author Karasik, B. S.; Il'in, K. S.; Ptitsina, N. G.; Gol'tsman, G. N.; Gershenzon, E. M.; Pechen', E. V.; Krasnosvobodtsev, S. I. url  openurl
  Title Electron-phonon scattering rate in impure NbC films Type Abstract
  Year 1998 Publication NASA/ADS Abbreviated Journal NASA/ADS  
  Volume Issue Pages Y35.08  
  Keywords NbC films  
  Abstract The study of the electron-phonon interaction in thin (20 nm) NbC films with electron mean free path l=2-13 nm gives an evidence that electron scattering is significantly modified due to the interference between electron-phonon and elastic electron scattering from impurities. The interference ~T^2-term, which is proportional to the residual resistivity, dominates over the Bloch-Grüneisen contribution to resistivity at low temperatures up to 60 K. The electron energy relaxation rate is directly measured via the relaxation of hot electrons heated by modulated electromagnetic radiation. In the temperature range 1.5 – 10 K the relaxation rate shows a weak dependence on the electron mean free path and strong temperature dependence T^n with the exponent n = 2.5-3. This behaviour is well explained by the theory of the electron-phonon-impurity interference taking into account the electron coupling with transverse phonons determined from the resistivity data.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference American Physical Society, Annual March Meeting, March 16-20, 1998 Los Angeles, CA  
  Notes Approved no  
  Call Number Serial 1591  
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gol'tsman, G. N. url  openurl
  Title Effect of electromagnetic radiation on a superconductor in a magnetic field Type Conference Article
  Year 1988 Publication Izv. Akad. Nauk SSSR, Seriya Fizicheskaya Abbreviated Journal Izv. Akad. Nauk SSSR, Seriya Fizicheskaya  
  Volume 52 Issue 3 Pages 449-451  
  Keywords  
  Abstract The effect of electromagnetic radiation on thin superconducting films of Nb with a large number of static defects is investigated experimentally for the case where the film is in the resistive state due to an applied magnetic field and transport current. The results obtained are found to be well described by a model of spatially homogeneous electron heating. It is noted that the results obtained here for Nb films are also valid for Al, NbN, and MoRe films.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Russian Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0367-6765 ISBN Medium  
  Area Expedition Conference 4th Vsesoiuznyi Seminar po Opticheskomu Detektirovaniiu Magnitnykh Rezonansov v Tverdykh Telakh, Tallin, Estonian SSR, Apr. 1987  
  Notes Approved no  
  Call Number Serial 1702  
Permanent link to this record
 

 
Author Gershenson, E. M.; Gol'tsman, G. N.; Elant'ev, A. I.; Kagane, M. L.; Multanovskii, V. V.; Ptitsina, N. G. url  openurl
  Title Use of submillimeter backward-wave tube spectroscopy in determination of the chemical nature and concentration of residual impurities in pure semiconductors Type Journal Article
  Year 1983 Publication Sov. Phys. Semicond. Abbreviated Journal Sov. Phys. Semicond.  
  Volume 17 Issue 8 Pages 908-913  
  Keywords BWO spectroscopy, pure semiconductors, residual impurities  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Применение субмиллиметровой ЛОВ спектроскопии для определения химической природы и концентрации примесей в чистых полупроводниках Approved no  
  Call Number Serial 1714  
Permanent link to this record
 

 
Author Gao, J. R.; Hajenius, M.; Baselmans, J. J. A.; Klapwijk, T. M.; de Korte, P. A. J.; Voronov, B.; Gol'tsman, G. url  openurl
  Title NbN hot electron bolometer mixers with superior performance for space applications Type Conference Article
  Year 2004 Publication Proc. Int. workshop on low temp. electronics Abbreviated Journal Proc. Int. workshop on low temp. electronics  
  Volume Issue Pages 11-17  
  Keywords NbN HEB mixers, applications  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Noordwijk Editor Armandillo, E.; Leone, B.  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference International workshop on low temperature electronics- WOLTE 6 - Noordwijk  
  Notes Approved no  
  Call Number Serial 1496  
Permanent link to this record
 

 
Author Boyarskii, D. A.; Gershenzon, V. E.; Gershenzon, E. M.; Gol'tsman, G. N.; Ptitsina, N. G.; Tikhonov, V. V.; Chulkova, G. M. url  openurl
  Title On the possibility of determining the microstructural parameters of an oil-bearing layer from radiophysical measurement data Type Journal Article
  Year 1996 Publication J. of Communications Technology and Electronics Abbreviated Journal J. of Communications Technology and Electronics  
  Volume 41 Issue 5 Pages 408-414  
  Keywords submillimeter waves, transmission  
  Abstract A method for the reconstruction of microstructural properties of an oil-bearing rock from the spectral dependence of the transmission factor of submillimeter waves is proposed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1064-2269 ISBN Medium  
  Area Expedition Conference  
  Notes Радиотехника и электроника 41, no. 4 (1996): 441-447 Approved no  
  Call Number Serial 1611  
Permanent link to this record
 

 
Author Kitaygorsky, Jennifer; Komissarov, I.; Jukna, A.; Minaeva, O.; Kaurova, N.; Divochiy, A.; Korneev, A.; Tarkhov, M.; Voronov, B.; Milostnaya, I.; Gol'tsman, G.; Sobolewski, R. url  openurl
  Title Fluctuations in two-dimensional superconducting NbN nanobridges and nanostructures meanders Type Abstract
  Year 2007 Publication Proc. APS March Meeting Abbreviated Journal Proc. APS March Meeting  
  Volume 52 Issue 1 Pages L9.00013  
  Keywords  
  Abstract We have observed fluctuations, manifested as sub-nanosecond to nanosecond transient, millivolt-amplitude voltage pulses, generated in two-dimensional NbN nanobridges, as well as in extended superconducting meander nanostructures, designed for single photon counting. Both nanobridges and nano-stripe meanders were biased at currents close to the critical current and measured in a range of temperatures from 1.5 to 8 K. During the tests, the devices were blocked from all incoming radiation by a metallic enclosure and shielded from any external magnetic fields. We attribute the observed spontaneous voltage pulses to the Kosterlitz-Thouless-type fluctuations, where the high enough applied bias current reduces the binding energy of vortex-antivortex pairs and, subsequently, thermal fluctuations break them apart causing the order parameter to momentarily reduce to zero, which in turn causes a transient voltage pulse. The duration of the voltage pulses depended on the device geometry (with the high-kinetic inductance meander structures having longer, nanosecond, pulses) while their rate was directly related to the biasing current as well as temperature.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1027  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: