|
Nebosis, R. S., Steinke, R., Lang, P. T., Schatz, W., Heusinger, M. A., Renk, K. F., et al. (1992). Picosecond YBa2Cu3O7−δdetector for far‐infrared radiation. J. Appl. Phys., 72(11), 5496–5499.
Abstract: We report on a picosecond YBa2Cu3O7−δ detector for far‐infrared radiation. The detector, consisting of a current carrying structure cooled to liquid‐nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far‐infrared laser in the frequency range from 25 to 215 cm−1. We found that the sensitivity (1 mV/W) was almost constant in this frequency range. We estimated a noise equivalent power of less than 5×10−7 W Hz−1/2. Taking into account the results of a mixing experiment (in the frequency range from 4 to 30 cm−1) we suggest that the response time of the detector was few picoseconds.
|
|
|
Semenov, A. D., Goghidze, I. G., Gol’tsman, G. N., Sergeev, A. V., & Gershenzon, E. M. (1993). Evidence for the spectral dependence of nonequilibrium picosecond photoresponse of YBaCuO thin films. Appl. Phys. Lett., 63(5), 681–683.
Abstract: The transient voltage photoresponse of current biased YBaCuO thin films to 20 ps laser pulses of 0.63 and 1.54 μm wavelengths is measured for temperatures around the superconducting transition region. The fast picosecond decay of the response is followed by a slow nanosecond relaxation which is associated with the bolometric effect. The magnitude of the fast component of the response varies in proportion to the square root of wavelength that plausibly reflects multiplication processes of photoexcited electrons via electron–electron scattering and interaction with high energy phonons.
|
|
|
Semenov, A. D., Gol’tsman, G. N., Gogidze, I. G., Sergeev, A. V., Gershenzon, E. M., Lang, P. T., et al. (1992). Subnanosecond photoresponse of a YBaCuO thin film to infrared and visible radiation by quasiparticle induced suppression of superconductivity. Appl. Phys. Lett., 60(7), 903–905.
Abstract: We observed subnanosecond photoresponse of a structured superconducting YBa2Cu3O7−δ thin film to infrared and visible radiation. We measured the voltage response of a current biased film (thickness 700 Å) in a resistive state to radiation pulses. From our results we conclude a response time of about 90 ps and a responsivity of about 4×1010 Ω/J. We attribute the response to Cooper pair breaking and suppression of the superconducting energy gap induced by nonequilibrium quasiparticles.
|
|
|
Fedorov, G. E., Stepanova, T. S., Gazaliev, A. S., Gaiduchenko, I. A., Kaurova, N. S., Voronov, B. M., et al. (2016). Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection. Semicond., 50(12), 1600–1603.
Abstract: Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed.
|
|
|
Akhmadishina, K. F., Bobrinetskiy, I. I., Komarov, I. A., Malovichko, A. M., Nevolin, V. K., Fedorov, G. E., et al. (2015). Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers. Semicond., 49(13), 1749–1753.
Abstract: The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin.
|
|