Sekine, N., & Hosako, I. (2009). Intensity modulation of terahertz quantum cascade lasers under external light injection. Appl. Phys. Lett., 95, 201106(1–3).
Abstract: We investigated the light-current characteristics of terahertz (THz) quantum cascade lasers under external light injection, which excites interband transitions in the active materials. It was found that the amount of reduction in the THz power was constant for all injection currents above threshold, and the dependence of the reduction amount on the wavelength of the external light was observed to show a resonancelike feature. The dominant intensity modulation mechanism was found to be the loss change caused by interband transitions in the active region. Further, the effective coupling efficiency plays an important role in the intensity modulation.
|
|
|
Cao, Q., Yoon, S. F., Tong, C. Z., Ngo, C. Y., Liu, C. Y., Wang, R., et al. (2009). Two-state competition in 1.3 μm multilayer InAs/InGaAs quantum dot lasers. Appl. Phys. Lett., 95(19), 3.
Abstract: The competition of ground state (GS) and excited state (ES) is investigated from the as-grown and thermally annealed 1.3 μm ten-layer p-doped InAs/GaAs quantum dot (QD) lasers. The modal gain competition between GS and ES are measured and analyzed around the ES threshold characteristics. Our results show that two-state competition is more significant in devices with short cavity length operating at high temperature. By comparing the as-grown and annealed devices, we demonstrate enhanced GS and suppressed ES lasing from the QD laser annealed at 600 °C for 15 s.
|
|
|
Yates, S. J. C., Baryshev, A. M., Baselmans, J. J. A., Klein, B., & Güsten, R. (2009). Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors. Appl. Phys. Lett., 95(4), 3.
Abstract: Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing ~1000 s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of fast Fourier transform spectrometer readout, showing no deterioration of the noise performance compared to the low noise analog mixing while allowing high multiplexing ratios.
|
|
|
Santavicca, D. F., Reulet, B., Karasik, B. S., Pereverzev, S. V., Olaya, D., Gershenson, M. E., et al. (2010). Energy resolution of terahertz single-photon-sensitive bolometric detectors. Appl. Phys. Lett., 96(8), 083505-3.
Abstract: We report measurements of the energy resolution of ultrasensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avoids problems with unwanted background photons. Present devices have an intrinsic full-width at half-maximum energy resolution of approximately 23 THz, near the predicted value due to intrinsic thermal fluctuation noise.
|
|
|
Zhang, W., Khosropanah, P., Gao, J. R., Kollberg, E. L., Yngvesson, K. S., Bansal, T., et al. (2010). Quantum noise in a terahertz hot electron bolometer mixer. Appl. Phys. Lett., 96(11), 111113–(1–3).
Abstract: We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The beta-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
|
|